Technical Data
BURNER
TYPE
MAX
OUTPUT
MIN
OUTPUT
G20
20mbar
G30/31
20-30/37mbar
G30
50mbar
Kw
Kw
Nozzle
Making
mm
Cons
M
3
/h
Nozzle
Making
mm
Cons
g/h
Nozzle
Making
mm
Cons
M
3
/h
Small
Auxiliary
burner
1.00
0.30
0.70
0.095
0.50
73
0.43
73
Medium
Semi-rapid
Burner
1.75
0.65
0.97
0.157
0.65
120
0.58
120
Large
rapid
burner
3.0
1.0
1.15
0.286
0.85
219
0.75
219
Triple
flame
burner
3.80
1.30
1.35
0.35
0.97
280
0.77
280
Gas intake connection
G1/2
″
Electricity supply
AC 220-240v 50/60Hz
Battery
supply DC 1.5v
Instructions for the installation technician
CAUTION: This appliance must only be installed and used in rooms with
permanent ventilation to local standards.
Installation of the appliance and its connection to the electrical mains must
only be carried out by QUALIFIED STAFF.
Before any procedure, it is important to check that the appliance is
DISCONNECTED from the electrical mains. The Manufacturer declines all
responsibility for any damage deriving from installation in breach of the
regulations in force or from failure to comply with the accident prevention
regulations.
10