background image

10  maintenance and service 

 Kelvinator gas continuous flow hot water system

Preventative maintenance can maximise the lifetime of this 
system. It's therefore recommended to have this system 
checked and serviced every 3 years. All servicing and repairs 
must be completed by a licensed technician. Please call 
the service centre (numbers located in the warranty section 
of this manual) for servicing and spare parts for your gas 
continuous flow hot water system. 

warning

Turn off the electrical power supply and close the manual 
gas control valve and the manual water control valve before 
servicing. 

caution

Before servicing or performing any maintenance on the 
hot water system, first ensure that the water heater is 
disconnected from the power supply to protect it from 
being damaged due to air in the system.

•  Clean the cold-water inlet filter.  

(Refer to the diagram below right) 

•  Be sure that all openings for combustion air are free from 

blockage. If blocked, remove the obstruction. 

•  Check that the opening for exhaust is not blocked. If 

blocked, shut off the water heater’s combustion. Wait 
until the system has completely cooled before removing 
the obstruction. DO NOT touch while the system is 
running – extremely high temperature can cause  
severe burns.  

•  Check the gas pressure. 
•  Keep the area around the system clear. Remove any 

combustible materials, gasoline or any flammable 
vapours and liquids. 

Water heater draining and filter cleaning

1.  Close the manual gas shut off valve. 
2.   Turn off the power supply to the system. 
3.   Close the manual water shut off valve. 
4.   Open all hot water taps in the house (bathroom, kitchen, 

laundry room, etc.). When the residual water flow has 
ceased, close all hot water taps. 

5.   Have a bucket or pan to catch the water from the water 

heater’s drain plugs. Unscrew the drain plugs to drain all 
the water out of the water heater. 

6.   Wait a few minutes to ensure all water has  

completely drained. 

7.   Clean the filter: Check the water filter located within the 

cold inlet. With a tiny brush, clean the water filter of any 
debris which may have accumulated and reinsert the filter 
back into the cold water inlet. 

8.   Securely screw the drain plugs back into place.  

Hand- tighten only. 

When it is safe to use the gas continuous flow water  
heater again: 

•  Ensure that power is switched off to the water heater  

or that it is unplugged.

•  Make sure all hot water taps are closed and the drain 

plugs are securely attached. 

•  Purge the water line of debris. 
•  Turn on the manual water control valve located on the 

water supply line. 

•  Open all the hot water taps to verify water flows to the 

taps. Close hot water taps. 

•  Turn on the manual gas control valve located on the gas 

supply line and check for leaks. 

•  Turn on the power supply to the system. 

      

      

      

      

 

 

 

turn off the water inlet 

supply valve then turn on 

a hot tap to release the 

pressure

remove filter 

by turning 

counterclockwise, 

clean and replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      

      

      

      

 

 

filter

Maintenance and service

Summary of Contents for KGC20BN Series

Page 1: ...Gas Continuous Flow Hot Water System User Manual...

Page 2: ...l indicates tips and information about economical and ecological use of the hot water system environmental tips Information on disposal for users Most of the packing materials are recyclable Please di...

Page 3: ...symbol indicates always do this warning Connect with power properly Otherwise it may cause electric shock or fire due to excess heat generation Always ensure effective earthing No earthing may cause...

Page 4: ...ds AS3498 provides full details of the requirements for the supply of controlled temperatures to bathrooms and is required to be conformed to under all Australian plumbing codes Do not store or use ga...

Page 5: ...ssist you in quoting its model number Rating label position Serial number label position Gas type label position MODELS KGC20 KGC26 Capacity L min 20L min 26L min Gas Input MJ h 160 195 Inlet Supply P...

Page 6: ...check for leaks Once water is flowing freely from the open hot tap or fixture indicating that all air has been dispelled from the system close the open hot water tap or fixture Open the gas isolation...

Page 7: ...filter of any debris Refer to page 10 for instructions 1 Fully open the manual water control valve on the water supply line 2 Open a hot water tap to verify that water is flowing to that tap then turn...

Page 8: ...erature by using the remote controller and mixing cold water as required Note If the Burner On display indicator is lit for safety reasons the temperature on the MAIN controller will not be able to be...

Page 9: ...e the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve located on the water supply line 4 Open all hot water taps in the house Bathroom kitch...

Page 10: ...r any flammable vapours and liquids Water heater draining and filter cleaning 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve 4...

Page 11: ...eep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Is the gas inlet filter in the water heate...

Page 12: ...12 notes Kelvinator gas continuous flow hot water system Notes...

Page 13: ...Kelvinator gas continuous flow hot water system notes 13 Notes...

Page 14: ...14 notes Kelvinator gas continuous flow hot water system Notes...

Page 15: ...is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a clai...

Page 16: ...formation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au...

Reviews: