roof installation – flat panel collectors  11

Roof installation –  

flat panel collectors

Collector pipe work connections

Open the fittings kit KKSSURA and check that all 
components have been supplied (see components list).
Place two 1/2" male to collector compression union fittings 
on the manifold pipes of the inlet and outlet of the collector 
array (the inlet to the collector array will be at the bottom 
and the outlet will be at the diagonally opposite corner at the 
top). Tighten the nut using two spanners as before, sealing 
the copper olive to the collector manifold pipes. 

solar collector

1/2" male 

to collector 

compression union

collector  

manifold  

pipe

Place the stopper fittings from the kit onto the remaining 
collector pipe work (also at diagonally opposite corners of 
the collector array) and tighten as before with two spanners. 

solar collector

stopper

collector  

manifold  

pipe

On the collector array outlet, install the two tee pieces, two 
nipples, sensor pocket, 1/2" to 3/8" reducing bush, vent valve 
and 1/2" female to copper union (see the diagram below). 
Between the fittings use an appropriate thread sealant that 
is capable of handling the high temperatures created by the 
collectors. Ensure the vent valve is installed so that its vent is 
pointing directly upwards, perpendicular to the ground (not 
the roof).

vent valve

1/2" female to 

copper union

sensor pocket

1/2" male to 

collector union

1/2" to 3/8"  

reducing bush

1/2"nipple

1/2"female T-piece

Once all the collectors are joined together (two or three 
collector installations only), they should be correctly 
positioned so that they are evenly distributed on the bottom 
rail. Place the collector clamps on the bottom rail over the 
top of the provided holes and insert the bolts through the 
holes in the clamps and bottom rail. Place the washers 
and nuts on the bottom of the bolts and tighten with two 
spanners, firmly clamping the collectors to the bottom rail.

If installing on an iron roof, line up a top strap with a 
horizontal roof strut (look for where the iron has been fixed) 
and the top side of the collector. Fix the top strap to the roof 
strut by either using an existing roofing screw or adding a 
new one.

If installing on a tiled roof, lift a tile above the collector and 
line up a top strap with a roof strut or truss and the top side 
of the collector. Fix the strap to the roof strut or truss and 
place the tile back to its normal position (same procedure as 
fixing the bottom strap).
Fix the top strap to the top side of the collector using a 
supplied self tapping screw and repeat for each additional 
collector (two or three collector installations only). 

Summary of Contents for KCT45036A

Page 1: ...Solar Hot Water Systems Installation Manual...

Page 2: ...d please contact your local authorities for the correct method of disposal warning Contact an authorised installer for installation of this hot water system Contact an authorised service technician fo...

Page 3: ...insulation may be required to comply with the requirements of AS NZS 3500 4 Plastic pipe MUST NOT be used as it will not withstand the temperature and pressure of the water generated by the solar col...

Page 4: ...copper fin with TiNOx selective coating Glazing 4mm low iron tempered patterned glass Insulation material 40mm glass wool Collector Evacuated tube KCPE12A Number of evacuated tubes per collector panel...

Page 5: ...pump type UP15 14B Circulation pump power 25W Rated voltage of circulation pump AC 220 240V Frequency 50Hz Model number KCT27000A KCT27036A KCT34000A KCT34036A KCT45036A Diameter mm 648 648 730 Height...

Page 6: ...the National Plumbing Standard AS NZS 3500 4 and local authority requirements Ensure the roof structure is suitable to carry the full weight of the solar collectors Each flat panel solar collector and...

Page 7: ...implement a water pre treatment process to bring the water quality to within acceptable limits to support the installation The saturation index SI is a measure of the corrosive or scaling properties...

Page 8: ...mm for three solar collectors If the roof material is uneven where the collectors are to be installed then it may be necessary to add an additional 10 mm to the above distances for each collector Spac...

Page 9: ...16 1 evacuated tube collector 17 1 connector evacuated tube collector 18 2 connector sleeve support evacuated tube collector 19 2 connector to 1 2 male for evacuated tube collector Supplied in kit KK...

Page 10: ...one for the bottom and are supplied in the mounting kit s solarcollectors collector manifold pipes compression union Slide the fittings onto one side of the collector manifold pipe to be joined and t...

Page 11: ...Ensure the vent valve is installed so that its vent is pointing directly upwards perpendicular to the ground not the roof ventvalve 1 2 femaleto copperunion sensorpocket 1 2 maleto collectorunion 1 2...

Page 12: ...ulations including AS3500 plumbing and drainage requirements and AS3000 electrical wiring standards Bottom rail connection viewed from above 10 15mm fromhorizontal bottomrail assembly 1 5m reliefvalve...

Page 13: ...e with all local regulations including AS5601 gas installation requirements AS3500 plumbing and drainage requirements and AS3000 electrical wiring standards Bottom rail connection viewed from above 10...

Page 14: ...to the manifold pipes of each collector Slide the fittings onto one side of the manifold pipe to be joined and then push both collectors together The collector manifold pipes shall be inserted as far...

Page 15: ...top brackets to the roof strut by either using an existing roofing screw or adding a new one Fix the top brackets to each side of the collector array with the supplied self tapping screws If installin...

Page 16: ...ealing the copper olive to the collector manifold pipes collector 1 2 male compression union Open the fittings kit KKSSURA and check that all components have been supplied see components list Since th...

Page 17: ...Bottom rail connection viewed from above 10 15mm fromhorizontal bottomrail assembly 1 5m reliefvalve uncontrolled hotwater outlet kitchen laundry tempered 50 C hot wateroutlet bathrooms tempering valv...

Page 18: ...umbing and drainage requirements and AS3000 electrical wiring standards Bottom rail connection viewed from above 10 15mm fromhorizontal bottomrail assembly reliefvalve uncontrolled hotwateroutlet kitc...

Page 19: ...m mounting surface to spread its load The storage tank shall be checked with a spirit level to ensure it is level for a number of reasons to ensure the correct positioning of the anode inside the tank...

Page 20: ...t water system under local plumbing requirements If the hot water system is installed in a bad water quality area where regular flushing is required due to sediment build up a drain cock or valve is a...

Page 21: ...e g bathroom or ensuite fixtures The water supplying these fixtures shall not exceed 50 C as required by AS 3500 4 heat trap uncontrolled hot water outlet kitchen laundry tempered hot water outlet 50...

Page 22: ...sensors should not be run alongside power supply cables as this may induce a false signal into the sensor cable Installing the collector array temperature sensor The collector sensor cable is provide...

Page 23: ...ng rules the local electrical authority regulations and any other applicable standards The pipe work storage tank and collectors are to be properly connected to the earthing system of the premises in...

Page 24: ...f the storage tank be completed first before the cable is wired to the switchboard If you are replacing an existing electric hot water system and re using the existing cable ensure that the power supp...

Page 25: ...ing the hot water system with water and checking for leaks At this stage the power to the tank element and pump station should be isolated off Fully open the cold water isolation valve located on the...

Page 26: ...that the temperature sensors are installed correctly connected to the solar controller and that the cables have not been damaged If the red LED is emitting continuous flashes this indicates that wate...

Page 27: ...e the isolation valve on the inlet piping Drain the water out of the system by activating the relief valve Remove the flow sensor from the circuit and re connect the collector array piping leaving the...

Page 28: ...with a thermometer if the water temperature in the bathroom is over 50 C if so the tempering valve may have an incorrect setting or be malfunctioning Please call a service technician Water is dischar...

Page 29: ...Kelvinator solar hot water systems notes 29 Notes...

Page 30: ...30 notes Kelvinator solar hot water systems Notes...

Page 31: ...sported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a claim under...

Page 32: ...er information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux c...

Reviews: