Kelvinator KCT27036A Installation Manual Download Page 31

Kelvinator solar hot water systems

  warranty  31  

This document sets out the terms and conditions of the product 

warranties for Electrolux Appliances. It is an important document. 

Please keep it with your proof of purchase documents in a safe place 

for future reference should you require service for your Appliance.

1.   In this warranty

(a)  ‘acceptable quality’ as referred to in clause 10 of this warranty has 

the same meaning referred to in the ACL;

(b)  ‘ACL’ means Trade Practices Amendment (Australian Consumer 

Law) Act (No.2) 2010;

(c)  ‘Appliance’ means any Electrolux product purchased by you 

accompanied by this document;

(d)  ‘ASC’ means Electrolux’ authorised serviced centres;

(e)  ‘Electrolux’ means Electrolux Home Products Pty Ltd of 163 

O’Riordan Street, Mascot, NSW 2020, ABN 51 004 762 341 in 

respect of Appliances purchased in Australia and Electrolux (NZ) 

Limited of 3-5 Niall Burgess Road, Mount Wellington, in respect of 

Appliances purchased in New Zealand;

(f)   ‘major failure’ as referred to in clause 10 of this warranty has the 

same meaning referred to in the ACL and includes a situation when 

an Appliance cannot be repaired or it is uneconomic for Electrolux, at 

its discretion, to repair an Appliance during the Warranty Period;

(g)  ‘Warranty Period’ means:

 

(i)   where the Appliance is used for personal, domestic or household 

use (i.e. normal single family use) as set out in the instruction 

manual, the Appliance is warranted against manufacturing 

defects in Australia and in New Zealand for the period of 1 year, 

following the date of original purchase of the Appliance. Specific 

components are warranted against manufacturing defects in 

Australia for the periods listed below if there is evidence provided 

to Electrolux that the Appliance was installed by a licensed 

plumber; and in New Zealand if there is evidence that the 

Appliance was installed according to the Electrolux installation 

guidelines which can be inspected on the Kelvinator website;

 

 

• Hot water tank cylinders - parts 5 years , labour 3 years

 

 

• Continuous  Gas

 

 

   - Heat Exchanger – parts 10 years, labour 3 years 

 

 

   - all others components - parts 3 years,  labour 3 years

 

 

• Heat Pump Refrigerant Sealed System - 2 years parts and labour

 

 

• Solar Collectors - parts 5 years, labour 3 years, 1 year for all 

other parts (mounting and connection sets)

 

(ii)   where the Appliance is used for commercial purposes (including 

being used to directly assist a business or where the Appliance is 

used in a multi-family communal or share type environment), the 

Appliance will then be warranted against manufacturing defects 

in Australia for 0 years and in New Zealand for 0 years, following 

the date of original purchase of the Appliance.

(h)  ‘you’ means the purchaser of the Appliance not having purchased 

the Appliance for re-sale, and ‘your’ has a corresponding meaning.

2.   This warranty only applies to Appliances purchased and used in Australia 

or New Zealand and is in addition to (and does not exclude, restrict, or 

modify in any way) any non-excludable statutory warranties in Australia 

or New Zealand.

3.   During the Warranty Period Electrolux or its ASC will, at no extra charge 

if your Appliance is readily accessible for service, without special 

equipment and subject to these terms and conditions, repair or replace 

any parts which it considers to be defective. Electrolux or its ASC may 

use remanufactured parts to repair your Appliance. You agree that 

any replaced Appliances or parts become the property of Electrolux. 

This warranty does not apply to light globes, batteries, filters or similar 

perishable parts.

4.   Parts and Appliances not supplied by Electrolux are not covered by this 

warranty.

5.   You will bear the cost of transportation, travel and delivery of the 

Appliance to and from Electrolux or its ASC. If you reside outside of the 

service area, you will bear the cost of:

(a)  travel of an authorised representative;

(b)  transportation and delivery of the Appliance to and from Electrolux or 

its ASC,

 

In all instances, unless the Appliance is transported by Electrolux or an 

Electrolux authorised representative, the Appliance is transported at the 

owner’s cost and risk while in transit to and from Electrolux or its ASC.

6.   Proof of purchase is required before you can make a claim under this 

warranty.

7.   You may not make a claim under this warranty unless the defect claimed 

is due to faulty or defective parts or workmanship. Electrolux is not liable 

in the following situations (which are not exhaustive):

(a)  the Appliance is damaged by:

 

(i)   accident

 

(ii)   misuse or abuse, including failure to properly maintain or service

 

(iii)  normal wear and tear

 

(iv)  power surges, electrical storm damage, excessive water pressure, 

excessive inlet water temperature or incorrect power supply

 

(v)   incomplete or improper installation

 

(vi)  incorrect, improper or inappropriate operation

 

(vii)  insect or vermin infestation

 

(viii) failure to comply with any additional instructions supplied with 

the Appliance;

 

(ix)  quality of water that is not in accordance with the “Water Quality” 

guidelines in the installation instructions;

(b)  the Appliance is modified without authority from Electrolux in writing;

(c)  the Appliance’s serial number or warranty seal has been removed or 

defaced;

(d)  the Appliance was serviced or repaired by anyone other than 

Electrolux, an authorised repairer or ASC.

8.   This warranty, the contract to which it relates and the relationship 

between you and Electrolux are governed by the law applicable where 

the Appliance was purchased. Where the Appliance was purchased in 

New Zealand for business purposes the Consumer Guarantee Act does 

not apply.

9.   To the extent permitted by law, Electrolux excludes all warranties and 

liabilities (other than as contained in this document) including liability for 

any loss or damage whether direct or indirect arising from your purchase, 

use or non use of the Appliance.

10. For Appliances and services provided by Electrolux in Australia, the 

Appliances come with a guarantee that cannot be excluded under the 

ACL. You are entitled to a replacement or refund for a major failure and 

for compensation for any other reasonably foreseeable loss or damage. 

You are also entitled to have the Appliance repaired or replaced if the 

Appliance fails to be of acceptable quality and the failure does not 

amount to a major failure. The benefits to you given by this warranty are 

in addition to your other rights and remedies under a law in relation to 

the Appliances or services to which the warranty relates.

11. At all times during the Warranty Period, Electrolux shall, at its discretion, 

determine whether repair, replacement or refund will apply if an 

Appliance has a valid warranty claim applicable to it.

12. For Appliances and services provided by Electrolux in New Zealand, 

the Appliances come with a guarantee by Electrolux pursuant to the 

provisions of the Consumer Guarantees Act, the Sale of Goods Act and 

the Fair Trading Act.

13. To enquire about claiming under this warranty, please follow these steps:

(a)  carefully check the operating instructions, user manual and the terms 

of this warranty;

(b)  have the model and serial number of the Appliance available;

(c)  have the proof of purchase (eg an invoice) available;

(d)  telephone the numbers shown below.

14. You accept that if you make a warranty claim, Electrolux and its ASC 

may exchange information in relation to you to enable Electrolux to meet 

its obligations under this warranty. 

 Warranty

FOR SALES IN AUSTRALIA AND NEW ZEALAND  

APPLIANCE: HOT WATER SYSTEMS

Important Notice

Before calling for service, please ensure that the steps listed in point 13 above have been followed.

FOR SERVICE 

or to find the address of your nearest 

state service centre in Australia 

PlEASE CAll 13 62 26  

For the cost of a local call (Australia only)

SERVICE AUSTRAlIA 

ELECTROLUX HOME PRODUCTS

www.electrolux.com.au

FOR SPARE PARTS 

or to find the address of your nearest 

state spare parts centre in Australia 

PlEASE CAll 1300 666 019 

For the cost of a local call (Australia only)

FOR SERVICE 

or to find the address of your nearest 

authorised service centre in New Zealand 

FREE CAll 0800 10 66 10 

(New Zealand only)

SERVICE NEW ZEAlAND 

ELECTROLUX HOME PRODUCTS

www.electrolux.co.nz

FOR SPARE PARTS 

or to find the address of your nearest 

state spare parts centre in New Zealand 

FREE CAll 0800 10 66 20 

(New Zealand only)

KHWS_Warr_Oct11

Summary of Contents for KCT27036A

Page 1: ...Solar Hot Water Systems Installation Manual ...

Page 2: ...ed please contact your local authorities for the correct method of disposal warning Contact an authorised installer for installation of this hot water system Contact an authorised service technician for repair or maintenance of this hot water system If a power cord is to be replaced replacement work must be performed by authorised personnel only Installation work must be performed in accordance wi...

Page 3: ...r insulation may be required to comply with the requirements of AS NZS 3500 4 Plastic pipe MUST NOT be used as it will not withstand the temperature and pressure of the water generated by the solar collectors under stagnation conditions The solar collectors can generate extremely high water temperatures of up to 272 C Plastic pipe can not withstand these temperatures Failure of plastic pipes can l...

Page 4: ... copper fin with TiNOx selective coating Glazing 4mm low iron tempered patterned glass Insulation material 40mm glass wool Collector Evacuated tube KCPE12A Number of evacuated tubes per collector panel 12 Collector dimensions mm length 1390 x width 1640 x depth 100 Gross surface area 2 28m2 Aperture surface 2 0m2 Collector capacity 1 6L Net weight 37kg Operating positive pressure max 1000kPa Stagn...

Page 5: ... pump type UP15 14B Circulation pump power 25W Rated voltage of circulation pump AC 220 240V Frequency 50Hz Model number KCT27000A KCT27036A KCT34000A KCT34036A KCT45036A Diameter mm 648 648 730 Height mm 1390 1690 1715 Tank capacity L 270 340 450 Net Weight kg 95 110 140 Tank wall thickness mm 2 5 3 3 Element rating if installed 3 6kW 3 6kW 3 6kW PTR valve pressure limit kPa 850 850 850 PTR valve...

Page 6: ... the National Plumbing Standard AS NZS 3500 4 and local authority requirements Ensure the roof structure is suitable to carry the full weight of the solar collectors Each flat panel solar collector and its fittings weigh approximately 45kg when full of water Each evacuated tube solar collector and its fittings weigh approximately 47kg when full of water If in doubt the roof structure should be sui...

Page 7: ...o implement a water pre treatment process to bring the water quality to within acceptable limits to support the installation The saturation index SI is a measure of the corrosive or scaling properties of the water supply Corrosive water SI 1 0 can corrode copper components In these conditions warranty will not apply Scaling water SI 0 5 can cause build up of CaCO3 Calcium carbonate which can impac...

Page 8: ... mm for three solar collectors If the roof material is uneven where the collectors are to be installed then it may be necessary to add an additional 10 mm to the above distances for each collector Space requirements A B C C D Space and load bearing requirements for evacuated tube collectors No of collectors Dimension A mm Dimension B mm Weight when full approx 1 1400 1640 47kg 2 2800 1640 94kg 3 4...

Page 9: ...n 16 1 evacuated tube collector 17 1 connector evacuated tube collector 18 2 connector sleeve support evacuated tube collector 19 2 connector to 1 2 male for evacuated tube collector Supplied in kit KKSSURA roof fittings kit Item No Qty Description 20 2 connector to 1 2 male for flat panel collector 21 2 stopper flat panel collector 22 2 union 1 2 female to copper 23 2 t piece 1 2 female 24 2 nipp...

Page 10: ...d one for the bottom and are supplied in the mounting kit s solarcollectors collector manifold pipes compression union Slide the fittings onto one side of the collector manifold pipe to be joined and then push both collectors together The collector manifold pipes should be inserted as far as possible into both sides of the compression union fitting Using two spanners tighten each nut on the compre...

Page 11: ...s Ensure the vent valve is installed so that its vent is pointing directly upwards perpendicular to the ground not the roof ventvalve 1 2 femaleto copperunion sensorpocket 1 2 maleto collectorunion 1 2 to3 8 reducingbush 1 2 nipple 1 2 femaleT piece Once all the collectors are joined together two or three collector installations only they should be correctly positioned so that they are evenly dist...

Page 12: ...gulations including AS3500 plumbing and drainage requirements and AS3000 electrical wiring standards Bottom rail connection viewed from above 10 15mm fromhorizontal bottomrail assembly 1 5m reliefvalve uncontrolled hotwateroutlet kitchen laundry tempered 50 C hotwateroutlet bathrooms tempering valve 20 30mm fromhorizontal 30 45mm fromhorizontal Connecting strap viewed from roof cavity Components s...

Page 13: ...ce with all local regulations including AS5601 gas installation requirements AS3500 plumbing and drainage requirements and AS3000 electrical wiring standards Bottom rail connection viewed from above 10 15mm fromhorizontal bottomrail assembly reliefvalve uncontrolled hotwateroutlet kitchen laundry tempered 50 C hotwater outlet bathrooms tempering valve 20 30mm fromhorizontal 30 45mm fromhorizontal ...

Page 14: ...nto the manifold pipes of each collector Slide the fittings onto one side of the manifold pipe to be joined and then push both collectors together The collector manifold pipes shall be inserted as far as possible into both sides of the compression union fitting solarcollectors coppersleeve support collector manifold pipes compression union Using two spanners tighten each nut on the compression uni...

Page 15: ... top brackets to the roof strut by either using an existing roofing screw or adding a new one Fix the top brackets to each side of the collector array with the supplied self tapping screws If installing on a tiled roof two twisted straps are to be fixed to the roof and each side of the collector array The twisted straps are to be fixed so that the twisted ends are flush with the sides of the colle...

Page 16: ...sealing the copper olive to the collector manifold pipes collector 1 2 male compression union Open the fittings kit KKSSURA and check that all components have been supplied see components list Since this kit is also used for flat panel type collectors there will be some pieces which will not be used On the collector array outlet install a tee piece 1 2 to 3 8 reducing bush vent valve 1 2 nipple an...

Page 17: ...Bottom rail connection viewed from above 10 15mm fromhorizontal bottomrail assembly 1 5m reliefvalve uncontrolled hotwater outlet kitchen laundry tempered 50 C hot wateroutlet bathrooms tempering valve 20 30mm fromhorizontal 30 45mm fromhorizontal Connecting strap viewed from roof cavity Components shown in grey are only used in 2 and 3 collector panel connections Secure with screws on top and bac...

Page 18: ...lumbing and drainage requirements and AS3000 electrical wiring standards Bottom rail connection viewed from above 10 15mm fromhorizontal bottomrail assembly reliefvalve uncontrolled hotwateroutlet kitchen laundry tempered 50 C hotwateroutlet bathrooms tempering valve 20 30mm fromhorizontal 30 45mm fromhorizontal Connecting strap viewed from roof cavity Components shown in grey are only used in 2 a...

Page 19: ...rm mounting surface to spread its load The storage tank shall be checked with a spirit level to ensure it is level for a number of reasons to ensure the correct positioning of the anode inside the tank to ensure that any hot water is drawn from the very top of the tank to assist air being dispelled during commissioning Consideration should be given to any potential damage due to water drainage or ...

Page 20: ...ot water system under local plumbing requirements If the hot water system is installed in a bad water quality area where regular flushing is required due to sediment build up a drain cock or valve is also to be installed on the inlet piping On the storage tank return connection install a 1 2 copper union 1 2 nipple and 3 4 to 1 2 reducing bush with appropriate thread sealant RETURN storagetankretu...

Page 21: ... e g bathroom or ensuite fixtures The water supplying these fixtures shall not exceed 50 C as required by AS 3500 4 heat trap uncontrolled hot water outlet kitchen laundry tempered hot water outlet 50 C bathrooms tempering valve Relief valve piping A temperature and pressure relief valve comes supplied with the storage tank and must be installed on the relief valve connection near the top of the t...

Page 22: ...e sensors should not be run alongside power supply cables as this may induce a false signal into the sensor cable Installing the collector array temperature sensor The collector sensor cable is provided in the kit KKSSURA and is 15m long It has a temperature sensor on one end that is required to be installed in the sensor pocket located on the outlet to the collector array and the connector at the...

Page 23: ...ing rules the local electrical authority regulations and any other applicable standards The pipe work storage tank and collectors are to be properly connected to the earthing system of the premises in accordance with AS NZS 3000 Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules The insulation of the fixed wiring must be protected by insulating sle...

Page 24: ...of the storage tank be completed first before the cable is wired to the switchboard If you are replacing an existing electric hot water system and re using the existing cable ensure that the power supply to this cable is isolated or disconnected at the switchboard The 20mm conduit adapter is to be inserted into the 20mm cut out provided and the locking ring screwed down to hold the conduit firmly ...

Page 25: ...ling the hot water system with water and checking for leaks At this stage the power to the tank element and pump station should be isolated off Fully open the cold water isolation valve located on the inlet to the storage tank to allow the system to begin filling with water Activate the temperature and pressure relief valve on the storage tank in order to allow air to bleed out of the tank outlet ...

Page 26: ...k that the temperature sensors are installed correctly connected to the solar controller and that the cables have not been damaged If the red LED is emitting continuous flashes this indicates that water is not circulating through the collectors and the storage tank correctly and that the temperature difference between them has been greater than 40 C for ten minutes There may be air in the system t...

Page 27: ...se the isolation valve on the inlet piping Drain the water out of the system by activating the relief valve Remove the flow sensor from the circuit and re connect the collector array piping leaving the flow restrictor in place Open the isolation valve on the inlet piping and refill the system with water ensuring that all air is bled as per the instructions provided The solar hot water system is no...

Page 28: ...k with a thermometer if the water temperature in the bathroom is over 50 C if so the tempering valve may have an incorrect setting or be malfunctioning Please call a service technician Water is discharging from the relief valve drainage pipe It s normal for a small amount of water to discharge during heating to allow for hot water expansion However if the relief valve appears to be continually lea...

Page 29: ...Kelvinator solar hot water systems notes 29 Notes ...

Page 30: ...30 notes Kelvinator solar hot water systems Notes ...

Page 31: ...nsported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by...

Page 32: ...her information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: