background image

 

 

 

 

 

 

 

Pizza Prep Tables   
Sandwich/Salad Units 
Under-counter Refrigerators and Freezers 
Worktop Refrigerators and Freezers                                                       

   

Service, Installation and Care Manual 

Please read this manual completely before attempting to install or operate this equipment. 

Notify carrier of damage!    Inspect all components immediately. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT INFORMATION   

READ BEFORE USE   

PLEASE SAVE THESE INSTRUCTIONS!

 

 

 

Summary of Contents for KCHMT29.12

Page 1: ...top Refrigerators and Freezers Service Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS ...

Page 2: ...re not followed If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the app...

Page 3: ...ur doivent éviter les dommages du tuyau réfrigérant ou le rique de la fuite Caution Risk of Fire or Explosion due to Flammable Refrigerant Used Follow Handling Instructions Carefully in Compliance with U S Government Regulations Component parts shall be replaced with like components and that servicing shall be done by factory authorized service personnel so as to minimize the risk of possible igni...

Page 4: ...quipment is shipped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon ope...

Page 5: ... 4 3 18 18 1 2 36 1365 3 17 408 5 15P PIZZA PREP TABLES MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft PAN 1 3 Size HP SHELF CAPACITY Sq ft BTU CHARGE OZ SHIP WEIGHT LBS NEMA PLUG KCHPT50 6 115 60 1 5 0 12 6 1 2 16 1365 3 7 348 5 15P KCHPT60 9 115 60 1 5 0 22 9 1 2 34 1365 3 7 432 5 15P KCHPT70 12 115 60 1 5 5 32 12 3 4 54 1877 3 7 582 5 15P UNDERCOUNTER WORKTOP REFRIGERATORS MODEL V Hz Ph AMPS STORAGE...

Page 6: ...It is recommended that the unit be installed no closer than 2 from any wall Leveling A level cabinet looks better and will perform better because the doors will line up with the frames properly Use a level to make sure the unit is level from front to back and side to side Units supplied with legs will have adjustable bullet feet to make the necessary adjustments If the unit is supplied with caster...

Page 7: ...ration temperature Top section is not intended for overnight storage Product should be removed from pans Pans can remain in cabinet if empty Defrosting Every 6 hours the unit will turn off so the evaporator coil can defrost The controller now displays the defrost symbol When the coil temperature reaches the terminal temperature or after 20 minutes of defrost the unit will turn on SOLID STATE THERM...

Page 8: ...ANUAL DEFFROST Push the key for more than 2 seconds and a manual defrost will start 2 4 HOW TO LOCK THE KEYBOARD 1 Hold the and keys for more than 3s 2 The POF message will be displayed and the keyboard will be locked At this point it will be possible only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3s the POF message will be displayed 2 5 HOW TO UNLOC...

Page 9: ...n condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor or cost to replace the compressor Never use a high pressure water wash for this cleaning procedure as water can damage the...

Page 10: ...ittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and don t require the use of tools or authorized service technicians The gaskets are Dart style and can be pulled out of the grove in the door and replaced by pressing the new one back into place Doors Hinges Over time...

Page 11: ...KCHUC48R KCHUCWT48R KCHUC60R KCHUCWT60R PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN OVERLOAD PROTECTOR COMPRESSOR FAN POWER EVAP FAN DOOR SWITCH PTC STARTER PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN OVERLOAD PROTECTOR COMPRESSOR FAN POWER EVAP FAN DOOR SWITCH PTC STARTER ...

Page 12: ... THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR FAN POWER EVAP FAN DOOR SWITCH L N PLUG THERMOSTAT DISPLAY CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR PTC STARTER CIRCUITALION FAN MOTOR t L N ROOM EVAP SENSOR DOOR FRAME HEATER ...

Page 13: ...OAD PROTECTOR COMPRESSOR ROOM EVAP SENSOR DOOR FRAME HEATER MIDDLE FRAME HEATER CONDENSER FAN MOTOR STARTING CAPACITOR CURRENT RELAY M M L N PLUG CIRCUITALION FAN MOTOR ROOM EVAP SENSOR DOOR FRAME HEATER MIDDLE FRAME HEATER MIDDLE FRAME HEATER CONDENSER FAN MOTOR STARTING CAPACITOR OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY THERMOSTAT DISPLAY ...

Page 14: ... KCHMT60 24 KCHMT60 24 2D PLUG CIRCUITALION FAN MOTOR ROOM EVAP SENSOR THERMOSTAT DISPLAY DOOR FRAME HEATER CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR t PTC STARTER L N PLUG CIRCUITALION FAN MOTOR L N ROOM EVAP SENSOR THERMOSTAT DISPLAY DOOR FRAME HEATER MIDDLE FRAME HEATER t CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR PTC STARTER ...

Page 15: ...STAT DISPLAY ROOM EVAP SENSOR DOOR FRAME HEATER MIDDLE FRAME HEATER MIDDLE FRAME HEATER CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR PTC STARTER t L N PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN THERMAL CUT OFF DEFROST HEATER OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR FAN POWER EVAP FAN DOOR SWITCH N L ...

Page 16: ...NG DIAGRAM MODEL KCHUC48F KCHUCWT48F PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN THERMAL CUT OFF DEFROST HEATER OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR MIDDLE FRAME HEATER FAN POWER EVAP FAN DOOR SWITCH N L ...

Page 17: ...Service and Installation Manual 17 WIRING DIAGRAM MODEL KCHUC27R KCHUCWT27R KCHUC27 2DR ...

Page 18: ...Service and Installation Manual 18 WIRING DIAGRAM MODEL KCHUC48R KCHUCWT48R KCHUC60R KCHUCWT60R ...

Page 19: ...Service and Installation Manual 19 WIRING DIAGRAM MODEL KCHUC72R KCHUCWT72R ...

Page 20: ...Service and Installation Manual 20 WIRING DIAGRAM MODEL KCHST27 8 KCHMT29 12 KCHMT29 12 2D ...

Page 21: ...Service and Installation Manual 21 WIRING DIAGRAM MODEL KCHST48 12 KCHMT48 18 KCHMT48 18 2D KCHST60 16 KCHMT60 24 KCHMT60 24 2D ...

Page 22: ...Service and Installation Manual 22 WIRING DIAGRAM MODEL KCHST70 18 KCHMT70 30 ...

Page 23: ...Service and Installation Manual 23 WIRING DIAGRAM MODEL KCHPT50 6 ...

Page 24: ...Service and Installation Manual 24 WIRING DIAGRAM MODEL KCHPT60 9 ...

Page 25: ...Service and Installation Manual 25 WIRING DIAGRAM MODEL KCHPT70 12 ...

Page 26: ...Service and Installation Manual 26 WIRING DIAGRAM MODEL KCHUC27F KCHUCWT27F ...

Page 27: ...Service and Installation Manual 27 WIRING DIAGRAM MODEL KCHUC48F KCHUCWT48F ...

Page 28: ...mages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God 15 For appliances operated by a concessionaire or vendor in a trailer or other motorized vehicle or at varying locat...

Page 29: ...s suelo gabinetes paredes etc 14 Daños provocados por servicios técnicos realizados por empresas de servicio no autorizadas uso de piezas que no sean las piezas genuinas de Electrolux o piezas obtenidas de personas que no sean las empresas de servicio técnico autorizado o causas externas como abuso uso incorrecto suministro de alimentación inadecuado accidentes incendios o casos fortuitos 15 Para ...

Page 30: ...s dommages causés par des réparations faites par des techniciens non autorisés l utilisation de pièces autres que les pièces Electrolux d origine ou des pièces qui n ont pas été obtenues par l entremise d un réparateur autorisé ou des causes externes comme l usage abusif le mauvais usage l emploi d une alimentation électrique inadéquate les accidents les incendies ou les catastrophes naturelles 15...