background image

                                                                                                                                                       

Service manual     

Refrigerator (freezer)                                               Double door serial 

 

9

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

YES 

NO 

YES 

NO 

NO 

NO

YES 

YES 

NO 

YES

 compressor runs 

Frost doesn’t form at the evaporator 
when operating set for more than 
30min 

Repair the 

compressor 

Refrigerant leaks poor 

compressing 

Power source   

separate the PTC-starter from the 
compressor and measure the voltage 
between M and C of the compressor

Equal to the applied 
voltage(rating voltage ±10%) 

The applied voltage is not in the 
range of rating voltage±10%     

Advice the customer to use in 
the fixed 

Check the 
resistance of the 
compressor 

Test the resistance among M-C, S-C, 
and M-S. 

Replace the compressor 

Check the 
resistance of the 
PTC 

Test the resistance of the both 
terminals in the PTC-STARTER 

Replace the PTC-STARTER

Check OLP 

Check if applying a 
regular OLP 

OLP works within 30sec, in forcible 
OLP operation by turning instant 
power on and off 

Replace OLP

Check the 
starting state 

Measure minimum starting voltage after 
checking steps1~3 above. And measure 
the pressure balance of the PTC with the
interval of more than 5 min 

Starts at the voltage 
of 85% below     

Normal 

Starts at the voltage of more than 90%   

Check the starting 
state at the regular 

Normal. 

Replace the PTC 

1

2

2

5

5

5

4

4

3

3

4

Summary of Contents for BCD-325WYHCE

Page 1: ...Service manual Refrigerator freezer Double door serial 1 Refrigerator service manual Double door serial MODEL RD 42WC4SFY BCD 325WYHCE ...

Page 2: ...2 Content 1 Safety precautions 3 3 2 Specification 4 4 3 Parts identification 5 5 4 Refrigeration system diagram 6 6 5 Circuit diagram 6 6 6 Maintenance service and Troubleshooting 7 10 7 Quality information report 11 11 8 Exploded view and part list 12 15 ...

Page 3: ...products in the freezer with wet hands this may cause frostbite 6 Prevent water from following onto electric elements in the mechanical parts 7 When tilting the refrigerator especially the thin plates ex Glass shelf or books 8 When servicing the evaporator wear cotton gloves This is to prevent injuries from the sharp evaporator fins 9 Leave the disassembly of the refrigerating cycle to a specializ...

Page 4: ...ed Grip grip Lock no Refrigerant R600a General Features Foam Blowing Agent cyclopentane Shelf Material No tempered glass 4 Door Basket PS 6 3big 3 small Interior Lamp yes Vegetable Crisper yes Vegetable Crisper Cover yes 2 small Egg Tray yes Can storage Dispenser no Refrigerator Compartment Deodorizer optional Star Rating 4 star Ice Maker Automatic Twist Normal normal Shelf Material No no Drawer P...

Page 5: ... Vegetable drawer Crisper cover Crisper Freezer Ice tray Inside Drawer in freezer Drawer in freezer Caster Door rack cover Door rack Egg rack inside Door switch Door rack Door rack Freezer Note Due to the updated modifications of our products your refrigerator may differ slightly from this Instruction Manual but the functions and using methods remain the same ...

Page 6: ...s just powered on The refrigerant flows in the sequence Compressor Condenser Dry filter Capillary tube Evaporator 5 Circuit diagram The electronic controller directly controls the start and stop of compressor and hence the refrigerator temperature The door switch directly controls the start and stop of the lamp ...

Page 7: ...it in the evaporator The system must be emptied and then refilled after eliminating the humidity Presence of air in the system Poor performance of the refrigerant system which is indicated on the evaporator with a slight frost which dose not freeze and an excessive overheating of the condenser and motor compressor There is air in a refrigerating system when during the filling phase vacuum is not e...

Page 8: ...be substituted and then proceed NO COOLING The compressor doesn t run Check the current flowing of starting system Shorted broken Replace the device Check if the current flows at the main coil of the compressor Coil shorted Replace the compressor Check the components on the main circuit Replace the components Check if the current flows at the contacting point of the thermostat Poor contacting poin...

Page 9: ...ixed Check the resistance of the compressor Test the resistance among M C S C and M S Replace the compressor Check the resistance of the PTC Test the resistance of the both terminals in the PTC STARTER Replace the PTC STARTER Check OLP Check if applying a regular OLP OLP works within 30sec in forcible OLP operation by turning instant power on and off Replace OLP Check the starting state Measure mi...

Page 10: ...ween NO 5 and 6 in the PTC with a multitester or Wheatstone bridge Normal Check another electric component The value is in the range of 14 28 for the 22 Ω PTC The value is 0 Abnormal Replace the PTC Separate the OLP from the compressor and check resistance value between two terminals of OLP with tester The value is Abnormal Replace the PTC Check another electric components Replace OLP ...

Page 11: ... more satisfied products please kindly fill in the questionnaire as the items indicated below We shall strive for best to optimize our products based on your suggestion Client name Sale area Date No Product model Quality problem describe Service result Quantity rate Factory serial No 1 2 3 4 5 6 Quality problem of whole sale product detail descriptions client suggest Factory activity ...

Reviews: