40
41
The X-terra 70 is capable of operating
in two different types of grounds,
magnetic (ie. inland parks) and
conductive (wet areas of salt water
beaches). Ground mineralisation
may cause false target signals in all
environments. Ground Balancing
the detector reduces these ground
signals and enables good targets to be
displayed and/or heard correctly.
Ground Balance (Normal)
Ground Balance (Normal) is suitable for
inland use and is operating when the
beach icon is off.
An unbalanced detector in Coin &
Treasure Mode will blank continuously
(if a pattern rejecting –8 is used) or
detect –8 continuously (if a pattern
accepting –8 is used).
An unbalanced detector in Prospecting
Mode will produce a continuous
‘warbling’ sound that differs from the
sharper sound of a real target signal.
Ground Balance (Beach)
Ground Balance (Beach) is suitable for
salt water beach use and is operating
when the beach icon is on.
In Ground Balance (Beach) the X-Terra
70 can Ground Balance any combination
of magnetic and conductive soil (e.g.
a mixture of sand, soil and salt water).
However, ferrous and some low
conductivity targets can be balanced
out. For this reason in Ground Balance
(Beach), Tracking should be used only
when targets are far apart.
GROUND BALANCE
41
Try reducing Sensitivity (pg. 30)
before Ground Balancing.
When detecting on the beach, adjusting
Ground Balance may not give signifi cant
improvements. Try adjusting Sensitivity
and altering Patterns for best results.
Activating Ground Balance
(Beach)
Press
GROUND
BALANCE
.
Press and hold
GROUND
BALANCE
for
three seconds. The beach umbrella
icon will appear to indicate that
Ground Balance (Beach) is activated.
To de-activate Ground Balance (Beach),
press and hold
GROUND
BALANCE
for
three seconds. The beach umbrella
icon will disappear indicating that
Ground Balance (Beach) is de-activated.
Press
PINPOINT
DETECT
or
GROUND
BALANCE
to return to detection.
Press and hold
GROUND BALANCE
for three seconds
to activate Ground
Balance (Beach)
Ground Balance settings aff ect both
normal detection and Pinpoint
operation.
Adjusting Ground Balance
The Ground Balance setting can be
adjusted in three ways, automatically,
manually, or with Tracking.
Auto Ground Balance will generally
give a good Ground Balance setting.
This may be further adjusted manually,
using the
+
and
–
buttons.
Adjust Ground Balance with
Auto, Manual or Track (pg. 42)
Press
GROUND
BALANCE
.
Adjust Ground Balance with Auto,
Manual or Track
(pg. 42).
Press
PINPOINT
DETECT
or
GROUND
BALANCE
to return to detection.
Summary of Contents for Minelab X-Terra 70
Page 1: ......