36
37
No sound
•
Check that the detector is on. Try turning both
the Threshold and Volume controls to maximum
•
Check that the battery pack and power cable
are connected securely
•
Check that the battery is charged
•
Try using a different battery pack, available from
your Minelab dealer
•
Check for breaks, cracks or extreme kinks in the
cable assemblies
Erratic Noises
•
Reduce the Sensitivity control by turning clockwise
•
Check that the battery is properly connected and
fully charged
•
Switch Sensitivity to the Auto position
•
Check for sand or grit between the skid plate and coil
•
Check for overhead power lines and other sources
of electrical interference
•
Check that the controls turn to the correct limits
(marked on the decal). Also check that the ‘clicks’
are present on the Threshold, Disc/Pinpoint and
Sensitivity controls.
Troubleshooting
Technical
Specifications
Transmission
1.5, 3, 4.5, 6, 7.5, 9 ... 25.5 kHz
Technology
BBS - Broad Band Spectrum Technology
Multiple Simultaneous Frequency
Coil (Standard)
8” or 10” Round Double D
Audio Output
6.35mm (¼") headphone socket
Koss Headphones supplied - Impedance 8W
Length with standard shaft
Extended - 1220mm
Retracted - 1140mm
Length with diving shaft
Extended - 910mm
Retracted - 820mm
Weight
Including 8" Coil - 1.96 kg approx.
Including 10" Coil - 2.23 kg approx.
Operating temperature range
0°C to 45°C (32°F to 113°F)
Storage temperature range
-20°C to 65°C (-4°F to 149°F)
Type
NiMH Battery Pack 1000 mAh
(Alkaline optional)
Output Voltage
13V when fully charged
Max discharge current is 1A
Capacity when fully charged
14 - 19 hours of use with the Excalibur II
Weight
0.31 kg approx.
Operating temperature range
0°C to 45°C (32°F to 113°F)
Storage temperature range
-20°C to 40°C (-4°F to 104°F)
Battery charge temperature range:
0°C to 45°C (32°F to 113°F)
Battery
Detector