Kelly Jaguar series KLS-N Sinusoidal Brushless PM Motor Controller User
’s Manual
V2.9
6
Kelly KLS-N - Sinusoidal Brushless Permanent Magnet Motor Controller
Model
Nominal
Voltage
Max Operating
Voltage
Peak Current**
1 Minute
Continuous
Current
KLS2412ND
12-24V
9-32V
140A
Up to 100A *
KLS2412N
12-24V
9-32V
140A
60A-100A
KLS2418ND
12-24V
9-32V
240A
Up to 135A *
KLS2418N
12-24V
9-32V
240A
80A-130A
KLS2430ND
12-24V
9-32V
280A
Up to 160A *
KLS2430N
12-24V
9-32V
280A
90A-150A
KLS4812ND
36-48V
27-60V
140A
Up to 100A *
KLS4812N
36-48V
27-60V
140A
60A-100A
KLS4818ND
36-48V
27-60V
240A
Up to 135A *
KLS4818N
36-48V
27-60V
240A
80A-130A
KLS4830ND
36-48V
27-60V
280A
Up to 160A *
KLS4830N
36-48V
27-60V
280A
90A-150A
KLS7212ND
48-72V
36-86V
140A
Up to 100A *
KLS7212N
48-72V
36-86V
140A
50A-90A
KLS7215ND
48-72V
36-86V
200A
Up to 110A *
KLS7215N
48-72V
36-86V
200A
60A-110A
KLS7218ND
48-72V
36-86V
240A
Up to 130A *
KLS7218N
48-72V
36-86V
240A
80A-120A
KLS7230ND
48-72V
36-86V
280A
Up to 150A *
KLS7230N
48-72V
36-86V
280A
90A-135A
KLS7240ND
48-72V
36-86V
320A
Up to 160A *
KLS7240N
48-72V
36-86V
320A
90A-150A
KLS8430ND
48-84V
40-100V
280A
Up to 150A *
KLS8430N
48-84V
40-100V
280A
90A-135A
Note: *Depends on conductive heat sink
**Peak current can be prolonged with additional heat sink, easily over 2 minutes.
Chapter 3 Wiring and Installation
3.1 Mounting the Controller
The controller can be oriented in any position which should be as clean and dry as possible,
and if necessary, shielded with a cover to protect it from water and contaminants.
To ensure full rated output power, the controller should be fastened to a clean, flat metal
surface with four screws. Applying silicon grease or some other thermal conductive material to
contact surface will enhance thermal performance.
Proper heat sinking and airflow are vital to achieve the full power capability of the controller.
The case outline and mounting holes
’ dimensions are shown below.