Kelly KHS High Voltage Sine Wave Brushless DC Motor Controller User
’s Manual
V 1.10
39
3,1
¤¤¤ ¤
Reserved
3,2
¤¤¤ ¤¤
Internal reset
May be caused by some transient fault condition like
a temporary over-current, momentarily high or low
battery voltage. This can happen during normal
operation.
3,3
¤¤¤ ¤¤¤
Hall throttle is open
or short-circuit
When the throttle is repaired, a restart will clear the
fault.
3,4
¤¤¤ ¤¤¤¤
Angle sensor error
1.Speed sensor type error
,
customers may set the
correct sensor type through user program or App.
Please download how to use Identification function
instruction from our website.
2. Incorrect wiring.
3. Speed sensor is damaged or defective. Or
feedback signal is erratic.
4,1
¤¤¤¤ ¤
Reserved
4, 2
¤¤¤¤ ¤¤
Reserved
4, 3
¤¤¤¤ ¤¤¤
Motor
over-temperature
Motor temperature is higher than the configured
maximum. The controller will shut down until the
motor temperature cools down.
4, 4
¤¤¤¤ ¤¤¤¤
Hall Galvanometer
sensor error
1. Hall galvanometer device is damaged inside the
controller.
This error code is only valid for KHS-I/IPS controller.
Customers may read error codes in PC software or Android Tablet