Kelly KBS-E Brushless Motor Controller User’s Manual
V 1.2
19
Controller Rated voltage Under Voltage Range (V) Over Voltage Range(V)
48V
18~60
18~60
72V
18~90
18~90
Figure 4.2
(6)Throttle Up/Down Rate
Value range: 0~100
Functional description: Pedal AD Sampling Frequency, a lower value means a shorter sampling
period and a faster respond rate.
Suggestion: Set according to the practical situation, factory default is 30.
(7)High Pedal Disable
Value range: Enable and Disable
Functional description: If enabled, the controller will detect the current pedal status at power up.
If throttle got effective output, the controller will report fault and not operate.
Suggestion: Set according to the practical situation, factory default is Enable.
(8)Releasing Brake High Pedal Disable
Value range: Enable and Disable
Functional description: If enabled, the controller will detect the current pedal status when
release the brake. If throttle got effective output, the controller will report fault and not operate.
Suggestion: Set according to the practical situation, factory default is Enable.
4.3 Step 3
(1)Motor Top Speed
Value range: 30%-100%
Functional description: Limit top speed of the motor.
Suggestion: Set according to the practical situation, factory default is 100%.
(2)Half Speed In Reverse
Value range: Enable and Disable
Functional description: If enabled, the max reverse speed of the motor will be limited to half of
the max forward speed.
Suggestion: This function is available for firmware version 0103 or less. Set according to the
practical situation, factory default is Disable.
(3)Boost Function
Value range: Enable and Disable
Functional description: Please see figure 4.3
Suggestion: Set according to the practical situation, factory default is Disable.
(4)Economy Function
Value range: Enable and Disable
Functional description: Please see figure 4.3
Suggestion: Set according to the practical situation, factory default is Disable.