Jetstream® DF | rear | C = 116 mm
Cut the wires between the original indicators
and the wire connectors at a suitable point. By
doing this the wiring loom stays untouched.
Connect your Jetstream® as follows:
To connect the wires of the indicator to the
wires of the original connector there are crimp
connectors and shrink tubings included in the
delivery. First push one of the shrink-on tubes
over one of the cables you want to connect and
remove five millimeter of insulation on the end
of each cable. Then push both bare ends into a
crimp connector and crimp it with an appropriate
tool. Then pull the shrink-on tube over the con-
nection and heat it up equally until it fits tight
over the complete length of the connector.
This type of connection is technically permanent.
To create a non-permanent connection, we re-
commend Posilock wire connectors (not inclu-
ded), which are available for purchase from our
website at
www.kellermann-online.com
.
Lay the cables in a way, that they are protected
from splash water and fasten them, e.g. by using
zip ties. Now test the function of the Jetstream®.
This completes the installation.
•
•
•
Connect the positive of the left (right) turn
signal to the grey wire of the left (right) Jet-
stream®.
Connect the black ground wire of the Jet-
stream® to battery ground.
Connect the red 12V supply cable of the Jet-
stream® to the ignition-switched battery plus.
The Jetstream® is now connected. To suppress
the system-related idle current, we recommend
an ignition-controlled i.SED module, which you
can order from
www.kellermann-online.com
.
Grey - Indicator
Black - Ground
Red - 12V Power Supply
INSTALLATION
ELECTRICAL CONNECTION
page 4