8.  Software for calibrators

The USB interface converter 

 

(K-114A) enables communication bet-

ween the calibrator and a computer. 

Before you connect the interface con-

verter to the computer, install driver 

K-104 / K-114 (the software CD is in-

cluded in scope of delivery, K-114A, or 

can be downloaded free of charge at 

www.keller-druck.com)

Settings on the medium pressure 

calibrator with the ManoConfig 

software 
Device settings such as the leak 

 

measurement time or the switch-off 

time for the calibrator can be adjusted 

using the "ManoConfig" software. 

Record measurements  

with the CCS30 software 
The CCS30 software records the data 

measured  by the pressure calibra-

tor, and shows them in both graphic 

and tabular form. Measured data 

can be saved or exported for fur-

ther  processing.  You  will  find  more  

information about the software in the 

CCS30 manual.

Step-by-step software installation 
Install from the CD or from  

www.keller-druck.com:

1.) K-104 / K-114 driver

2.) (CCS30) Control Center Series 30 

3.) ManoConfig (if desired)

ManoConfig

18

Control Center

CCS30

Summary of Contents for MPX

Page 1: ...Operating instructions for the medium pressure calibrator MPX...

Page 2: ...3 Operating the MPX calibrator 15 4 Description of the functions 15 5 Menu navigation for calibrators 16 6 Commissioning 16 7 Maintenance disposal 17 8 Software for calibrators 18 Technical data 19 Sp...

Page 3: ...e cable K 104A or K 114A PC connection RS485 2 Device base 3 Display 4 SELECT and ENTER buttons 5 Hand pump integrated in the device 6 Vacuum pump 7 Pressure relief valve 8 Fine tuning valve 9 Pressur...

Page 4: ...t Zero To re set the pressure zero point to absolute pressure use the RES Zero function reset zero Commissioning A pressure resistant connection for the test object is required in order to use the med...

Page 5: ...pres sure connection for the test object 9 Connect the test object and the vacuum pump 6 to the Y coupler Use the vacuum pump to lower the pressure You can then fine tune the pressure by screwing the...

Page 6: ...n max display or the Leak function Using the functions Written descriptions of the individual functions are given below in addition to the diagram above Selecting functions The individual sub function...

Page 7: ...are Software for calibrators MANO Continuous function Automatic switch off function the device switches off automatically 15 minutes after a button was last pressed Leak measurements are canceled by t...

Page 8: ...delivery K 114A or can be downloaded free of charge at www keller druck com Settings on the medium pressure calibrator with the ManoConfig software Device settings such as the leak measurement time or...

Page 9: ...e Fischer cable socket on the side fits the K 104A K 114A interface converter Compensated temperature range 0 50 C Operating temperature 0 50 C Storage temperature 10 60 C Air humidity 5 95 relative h...

Page 10: ...x Test object adapter G 1 4 M G 3 8 F 506810 0028 x Test object adapter G 1 4 M G 1 2 F 506810 0013 x Sealing ring G 1 8 508635 0001 x x Sealing ring G 1 4 508635 0002 x x CrNi filter 307025 2011 x x...

Reviews: