Keller MPX Operating Instructions Manual Download Page 10

20

Description

Article number

LPX

MPX

HPX

Illustration

Carrying case, empty

309025.0005

x

x

x

Battery, type CR2430

557005.0001

x

x

x

Hose nipple

508832.0005

x

x

Connecting nipple, G 1/4”  

including sealing ring

508832.0004

x

x

Y-coupler

307025.0001

x

Test object adapter,  

G 1/4”M–G 3/8”F 

506810.0028

x

Test object adapter,  

G 1/4”M–G 1/2”F

506810.0013

x

Sealing ring, G 1/8”

508635.0001

x

x

Sealing ring, G 1/4”

508635.0002

x

x

CrNi filter

307025.2011

x

x

Vacuum pump

309005.0005

x

x

Hand pump

309005.0004

x

Fine-tuning valve

309030.0006

x

x

Bottle of oil, 0,5 l  

(HLP 22 BP hydraulic oil)

650505.0005

x

K-114A

309010.0075

x

x

x

Spare parts and accessories for KELLER pressure calibrators

suitable for

Summary of Contents for MPX

Page 1: ...Operating instructions for the medium pressure calibrator MPX...

Page 2: ...3 Operating the MPX calibrator 15 4 Description of the functions 15 5 Menu navigation for calibrators 16 6 Commissioning 16 7 Maintenance disposal 17 8 Software for calibrators 18 Technical data 19 Sp...

Page 3: ...e cable K 104A or K 114A PC connection RS485 2 Device base 3 Display 4 SELECT and ENTER buttons 5 Hand pump integrated in the device 6 Vacuum pump 7 Pressure relief valve 8 Fine tuning valve 9 Pressur...

Page 4: ...t Zero To re set the pressure zero point to absolute pressure use the RES Zero function reset zero Commissioning A pressure resistant connection for the test object is required in order to use the med...

Page 5: ...pres sure connection for the test object 9 Connect the test object and the vacuum pump 6 to the Y coupler Use the vacuum pump to lower the pressure You can then fine tune the pressure by screwing the...

Page 6: ...n max display or the Leak function Using the functions Written descriptions of the individual functions are given below in addition to the diagram above Selecting functions The individual sub function...

Page 7: ...are Software for calibrators MANO Continuous function Automatic switch off function the device switches off automatically 15 minutes after a button was last pressed Leak measurements are canceled by t...

Page 8: ...delivery K 114A or can be downloaded free of charge at www keller druck com Settings on the medium pressure calibrator with the ManoConfig software Device settings such as the leak measurement time or...

Page 9: ...e Fischer cable socket on the side fits the K 104A K 114A interface converter Compensated temperature range 0 50 C Operating temperature 0 50 C Storage temperature 10 60 C Air humidity 5 95 relative h...

Page 10: ...x Test object adapter G 1 4 M G 3 8 F 506810 0028 x Test object adapter G 1 4 M G 1 2 F 506810 0013 x Sealing ring G 1 8 508635 0001 x x Sealing ring G 1 4 508635 0002 x x CrNi filter 307025 2011 x x...

Reviews: