3
keller-druck.com
Product overview
The data loggers in Series DCX are autonomous, battery-powered data collectors
which can measure the water level (water column, i.e. pressure) and temperature over
lengthy periods.
Series DCX is designed for level measurements and is generally used for long-term
data acquisition in applications with brackish water, salt water or fresh water.
Series DCX is also available with a connecting thread for process applications.
Various versions are available in Series DCX. The standard material is stainless steel,
316L (DIN 1.4435). For added resistance to media, the logger can be manufactured to
order from Hastelloy or titanium as options. The key distinguishing features of products in
Series DCX are their measuring methods and the diameter of the probe.
Designation
Measuring
principle
Max.
pressure range
Max. mH2O
Max. cable length**
DCX-16
absolute
0,8…11 bar abs.
0…100 mH2O
–
DCX-16 VG
relative
0…10 bar rel.
0…100 mH2O
500 meters
DCX-16 SG
absolute
0,8…11 bar abs.
0…100 mH2O
500 meters
DCX-18
absolute
0,8…11 bar abs.
0…100 mH2O
–
DCX-18 VG
relative
0…10 bar rel.
0…100 mH2O
500 meters
DCX-18 SG
absolute
0,8…11 bar abs.
0…100 mH2O
500 meters
DCX-22
absolute
0,8…11 bar abs.
0…100 mH2O
–
DCX-22 Baro
absolute
0,8…1.3 bar abs.
0…100 mH2O
–
DCX-22 VG
relative
0…10 bar rel.
0…100 mH2O
500 meters
DCX-22 SG
absolute
0,8…11 bar abs.
0…100 mH2O
500 meters
DCX-22 AA
absolute/absolute
0,8…11 bar abs.
0…100 mH2O
80 meters
DCX-25 PVDF
absolute
0,8…11 bar abs.
0…100 mH2O
–
DCX-38 VG
relative
0…
300 mbar rel.
0…3 mH2O
500 meters
DCX-22 AA
Probe diameter
16 = Ø 16 mm
18 = Ø 18 mm
22 = Ø 22 mm
25 = Ø 25 mm
38 = Ø 38 mm
Version
....
Absolute pressure measurement / without cable
VG
Relative pressure measurement / with cable
SG
Absolute pressure measurement / with cable
AA
Absolute pressure measurement with 2 sensors / with cable
PVDF For use in aggressive media.
Special housing made of polyvinylidene fluoride (PVDF) with high
resistance to chemicals / Available for probe diameter of 25 mm,
without cable only
** For other system lengths, please contact our sales staff
Maximum pressure ranges and cable lengths