1 General

     This manual gives you brief information on how to properly install the pyrometer of the PA 8x 

series. Detailed information can be downloaded from our website www.keller.de/its/.

2  Explanation of symbols

Important notes in this manual are marked with a symbol.

ATTENTION

This symbol points out guidelines. If you do not observe them, the device 

might be damaged, malfunctioning or even fail to operate.

This symbol points out hints and information which should be heeded for efficient and 

trouble-free operation.

This symbol instructs the operator to take action.

>

Response, Result. This symbol indicates the result of the action.

3  Laser safety instructions

Class 2 Laser Product   

•  Never look directly into the laser beam path  

 

(emitted power <1.0 mW at a wavelength of 630-670 nm)

•  Do not leave the instrument unattended when the laser is activated.
•  Do not point the laser beam at any person.
•   During pyrometer installation and alignment, make sure to avoid the possibility of laser light 

reflections caused by reflective surfaces.

•  All currently valid laser safety standards must be observed.

Laser Warning Label 

 

The black and yellow laser warning label is affixed next to nameplate of the instrument. An arrow 

indicates the laser emission path (lens opening).

4  Selecting an installation location

When choosing the installation location and during the pyrometer alignment, it is imperative to 

ensure that only the free pouring stream is within the field of view.
When the background is hotter than the object focused on or when the measurement is made 

through the inoculant, the accuracy of measurement will be influenced. 
The pyrometer should be oriented as far as possible at right angles to the pouring stream. Ide-

ally, the pyrometer should be mounted so that it is aligned with the back of the pouring stream.

Pyrometer CellaCast PA 8x

Quick start guide

Quick Start Guide CellaCast PA 8x

Summary of Contents for CellaCast PA8 Series

Page 1: ...PYROMETER CellaCast PA 8x Ident no 1117989 05 2022 QUICK GUIDE...

Page 2: ......

Page 3: ...ivated Do not point the laser beam at any person During pyrometer installation and alignment make sure to avoid the possibility of laser light reflections caused by reflective surfaces All currently v...

Page 4: ...th a maximum pressure of 6 bars are required for that Use oil free and dirt free compressed air If the expected ambient temperatures are 65 C a cooling system is required 1 Target size 2 Pouring strea...

Page 5: ...4 20 mA 0 24 V 0 24 V 0 10 V shielded Digital IN OUT1 IN OUT2 Analogue OUT1 OUT2 Analogue IN 1 2 3 4 5 6 7 8 Pin 1 WH white L Power supply 24V DC Pin 2 BN brown Digital in out 1 Pin 3 GN green Analogu...

Page 6: ...tate instrument alignment to the target spot To activate the laser press the MODE button on the rear panel for 2 seconds Alternatively the laser can be switched on with the interface To focus rotate t...

Page 7: ...nt To do this set the pyrometer to the same distance as the distance between the pyrometer and the pouring stream 9 Parameterization On delivery the pyrometer is parameterized on a discontinuous pouri...

Page 8: ...displayed Press Mode The current sampling time or Auto is displayed Press or for 2 second The display flashes three times Press or to set the desired sampling time Press Mode to confirm the parameter...

Page 9: ...r Press or to change to the parameter End Then Press Mode to change to the functional menu In the functional menu press or to change to the parameter End then press Mode Alternatively the parameters c...

Page 10: ...vity ratio carry out a new control measurement The emissivity ratio is set as follows Press or for 2 seconds The value of the selected emissivity ration is displayed for example 103 0 Press or until t...

Page 11: ...If the period for filing claims has expired you will no longer be able to make any claims for compensation of damage or loss Packing The packages used are made of carefully selected environmentally co...

Page 12: ...or in part for any purpose whatsoever without prior consent of the author This applies to any form of mechanical or electronic reproduction as well as to electronic transmission in any form through a...

Reviews: