www.keller-druck.com
Version 08/2020
Seite 14 von 24
6
Configuration
The user can configure a rich set of device parameters, such as measuring interval, LoRaWAN® band, data rate, ADR
Settings, power level and many more. The parameter will be stored permanently in the internal non-volatile memory.
The user can configure the device via two interfaces:
•
Command line interface: via a Micro USB (Type B) cable connected to a computer
•
Downlink command interface: over the air using LoRaWAN® downlink messages
For a full description of the command line interface and the downlink command interface, please find the specific
documents on
6.1
Description
„
ADT1 Configurat
ion“
6.1.1
Overview
Number
Description
Explanation / Function
1
Language Selector
Select the preferred language
2
Serial Communication Port
Select the appropriate port number
3
Read Configuration Button
Press button to read configuration from connected device
4
Write Configuration Button
Press button to write configuration to connected device
5
Open Configuration File
Press button to open an existing (previously saved) configuration file
6
Save Configuration
Press button to save all settings to a configuration file
7
Checkbox “Set ADT1 time to PC time at
write configuration”
Enable checkbox -> The ADT1 clock will automatically be synchronized with PC clock if you
press the “
Write
Configuration Button”
-> see number 4
8
Date and Time Selector and Edit Field
You may manually set a date and time by selection or editing the fields
9
“Now” Button
Press button to set the ADT1 time field to PC time.
10
“Write” Button
Press button to write time and date to the device. Please notice the button may be disabled
according to the state of checkbox number #7
11
“Read“ Button
Press button to read time and date from the device