.Main construction Data 

Type: 

Rated 
Power

Supply 
Current 

Power 
factor 

protective 
shield  

Weigh

Maximum 
projected 
area 

Dimensions 

Remark: 

1524223

 

10W    Max.60 

mA 

0.5 

98.4*77.4*
4mm 

0.469k

204.6cm

 

124*59*165m
m   

Electric shock 

protection class: I 

External light 

protection class: 

IP65 

Rated voltage: 
220-240V~ 
50/60Hz 

Mounting 

height:<3m 

Universal for 

operating 

position. 

 

1524225

 

30W 

Max.130 
mA 

0.9 

172.8*132.
8*4mm 

0.79kg  439.8cm

2

 

199*58.5*221
mm 

1524227

 

50W 

Max.220 
mA 

0.9 

202.4*154.
4*4mm 

1.011k

562.2cm

2

 

229*60.5*245.
5mm 

.Safety instructions 

1. Before mounting and maintenance please make sure that the electrical supply has been switched off to 

avoid electric shock.   

2. The lamp must be earthed. 
3. The power cord should be VDE-certified H05RN 3x1.0mm

2

 or H07RN-F 3x1.0mm

waterproof cable. 

4.The lamp can be mounted on normally flammable surfaces. 
5

.

The external flexible cable or cord of this luminaire cannot be replaced. If the cord is damaged, the 

luminaire shall be destroyed. 

. Assembly 

1.Turn off the power. (see Fig 01) 
2.Determine the installation location and mark the wall. (see Fig 02.1)   
3. Drill holes with an electric drill at the marked locations.(see Fig 02.2) 
4. Plugs into wall mounting holes with included plastic expansion.

see Fig 02.3) 

5. Use the tool to fasten the included screws, flat washers and fixing brackets to the mounting holes.(see Fig 

02.4) 

6.Tighten the screws on the mounting bracket with a tool.(see Fig 02.5) 

7. The plug is connected to the power socket.(see Fig 02.6) 

8. Switch on the power for use.(see Fig.03)   

 

.Operation 

1.  The lamp is only suitable for mounting on the wall.The installation height must be less than 3m.(see Fig. 

03)   

2.  The lamp can be tilted down 90

0

 and upward 90

0

.(see Fig. 03)   

3.  The sensor can be rotated 75 degrees left and right, 70 degrees forward, and 90 degrees backward.(see 

Fig. 04) 

4.  The product is equipped with motion sensor which the detection angle is 180° and the max detection dist

ance is 12m.(see Fig.05) 

5.  The infrared detector is equipped with three adjusting knobs.(see Fig.06) 

  Time adjustment: 

Using this controller,you can select any switch-on time between approx.10±5 seconds and 5±1 minutes 

after the last motion was detected.Rotating the TIME controlley clockwise decreases the time 

period,rotating it counterclockwise increases it. 

  Daylight adjustment: 

The light adjustment determines from what brightness level the sensor will switch on the floodlight

The( sun symbol )position indicates that the sensor works by day and at night,in the(moon 

symbol)position,the  sensor will only work at night.To adjust the sensor,wait until the desired ambient 

brightness is reached.Completely rotate the light adjustment controller to the(moon)symbol.Slowly rotate 

the controller in the direction of the (sun)symbol until the floodlight is switched on by the motion. The 

Reviews: