background image

display”23”by  default.Press”      /        “to  set  target  temperature.  During  open-window 
detection mode,

 

once the ambient temperature drops 5-10℃  within 10 minutes, then the 

product  will  stop  working  within  30  minutes  and  enter  into  stand  by  mode.  Then  press 

”to turn on the product. 

Press    ”      “ again to turn off the open-window detection, the light “ 

  ”will go off 

and the product will resume to previous working mode. 

Below is an example to set 23℃  during open-window detection.See below :F 
3).When turn on at the same time for both open-window detection and weekly program, 

during the OFF period of weekly program, the product doesn’t work. During the working 
status  of  weekly  program,  the  temperature  is  subject  to  the  setting  temperature  of 
open-window detection. See below :G 

 

Note: 

-

 

Before turn on weekly program: it must set day and time period,otherwise the weekly 

default state is “00”, which does not work. 

 
         

          F                                                            G

 

 
 
 
 
 
 
 
 
 
 

Specifications 

Power Supply: AC 220-240V ~ 50Hz 
Power Consumption: 2000W   

Class II 

 

REMOTE CONTROL 

The remote control requires 1 CR2025 3V lithium battery 

 

Important: Follow the instructions of use and the recycle rules given on the battery packaging. 

1- Open the battery compartment by sliding the cover down.

 

2- Insert the battery into the compart-ment,   

observing the polarity in the dia-gram (see below drawing).

 

3- Close the battery compartment.

                           

 

 
 

 
 
 

 

Summary of Contents for KTP2090

Page 1: ...Manual de instrucciones Instruction manual REF KTP2090 8445401003786 Calefactor Pared Cer mico PTC Split Dual Ultraslim 2000W c mando 59 x 14 x 22 cm...

Page 2: ...uso y mantenimiento CONSEJOS DE SEGURIDAD uso Este aparato puede ser utilizado por ni os a partir de 8 a os y personas con capacidades f sicas sensoriales o mentales reducidas o con falta de experien...

Page 3: ...debe alimentarse a trav s de un dispositivo de conmutaci n externo como un temporizador ni conectarse a un circuito que se encienda y apague regularmente por la empresa de servicios p blicos ADVERTENC...

Page 4: ...El pasador debajo del gancho debe introducirse en la parte inferior del calefactor Panel de control Mando a distancia Uso de las funciones en la m quina y con el mando a distancia Bot n de control Pa...

Page 5: ...a pulsar una cuarta vez para entrar en modo de espera la pantalla mostrar como en la foto A El ventilador fr o funcionar durante 30 segundos y entrar en modo de espera A B C 3 Pulse el bot n para con...

Page 6: ...ogramaci n de la hora de encendido en 8 horas Nota si no configura la temperatura y el programa semanal el producto se apagar autom ticamente despu s de 12 horas de funcionamiento continuo y entrar en...

Page 7: ...ngo d1 d7 Despu s pulse para confirmar la configuraci n la pantalla mostrar la configuraci n anterior Por ejemplo ajuste al mi rcoles 9 30 a m a 25 con calefacci n II Consulte las siguientes im genes...

Page 8: ...nfigurar la temperatura La pantalla se apagar y mostrar Tras funcionar con calefacci n continua durante 12 horas el ventilador de refrigeraci n funcionar durante 30 segundos y el producto entrar en mo...

Page 9: ...pera vea el ejemplo E a continuaci n 7 Pulse para definir la temperatura objetivo rango de temperatura 10 49 8 Repita los pasos 3 a 7 anteriores para configurar todo el programa semanal Despu s pulse...

Page 10: ...de ventana abierta la luz se apagar y el producto volver al modo de funcionamiento anterior A continuaci n se muestra un ejemplo para configurar la temperatura a 23 durante la detecci n de ventana abi...

Page 11: ...ca la lave directamente con agua ni permita que le caiga agua Nunca la limpie con cidos disolventes qu micos gasolina benceno etc Antes de volver a usarlo verif quelo y aseg rese de que ning n objeto...

Page 12: ...ventilador NO Con potencia calor fica nominal elm x 0 kW Tipo de control de potencia calor fica temperatura ambiente seleccione uno Con potencia calor fica m nima elmin 0 kW Potencia calor fica de una...

Page 13: ...e SAFETY ADVICE Use This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have...

Page 14: ...rmal cutout this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility WARNING In order to...

Page 15: ...and hang the heater The clip under the pothook should be inserted rabbet of the heater bottom Control panel Remote control Function operation both machine remote control Control button LED display Rec...

Page 16: ...es to high heating and display shows like photo C then Press fourth time enter into in standby mode and display shows like photo A the cool fan will work for 30seconds and enter into standby mode A B...

Page 17: ...ng appointment turn on Below photos is an example to set appointment turn on time to 8 hours Note If not setting the temperature and weekly program the product will automatically turn off after 12 hou...

Page 18: ...firm the setting the display will show previous settings For example Setting to Wednesday 9 30 AM under 25 under II heating pls refer to the following photos Note After the product is power off it nee...

Page 19: ...ct will work without setting temperature While the display will go off and will show After continuous heating for 12hours the cool fan will work for 30seconds and enter into standby mode Set weekly pr...

Page 20: ...kly program Then press to confirmed 9 To cancel the weekly function press the agian the light P will go off The weekly program is off The product will revert to the previous function working status No...

Page 21: ...FF period of weekly program the product doesn t work During the working status of weekly program the temperature is subject to the setting temperature of open window detection See below G Note Before...

Page 22: ...fore use it again please check it and make sure the outlet ventilation have no sundries Environment Meaning of crossed out wheeled dustbin Do not dispose of electrical appliances as unsorted municipal...

Page 23: ...isted heat output NO At nominal heat output elmax 0 kW Type of heat output room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature contro...

Page 24: ...s Moreras 1 Naves 7 10 Pol Ind Camporrosso Sur 28350 Madrid Oficina Tel 34 911 34 50 46 Email info kovyx com Servicio Post Venta Tel 34 918 09 62 29 Email spv kovyx com Av de Andaluc a 208 28341 Valde...