Do not connect switching cards directly to unlimited power circuits. They are intended 

to be used with impedance-limited sources. NEVER connect switching cards directly to 

AC mains. When connecting sources to switching cards, install protective devices to 

limit fault current and voltage to the card. 
Before operating an instrument, ensure that the line cord is connected to a 

properly-grounded power receptacle. Inspect the connecting cables, test leads, and 

jumpers for possible wear, cracks, or breaks before each use. 
When installing equipment where access to the main power cord is restricted, such as 

rack mounting, a separate main input power disconnect device must be provided in 

close proximity to the equipment and within easy reach of the operator. 
For maximum safety, do not touch the product, test cables, or any other instruments 

while power is applied to the circuit under test. ALWAYS remove power from the 

entire test system and discharge any capacitors before: connecting or disconnecting 

cables or jumpers, installing or removing switching cards, or making internal changes, 

such as installing or removing jumpers. 
Do not touch any object that could provide a current path to the common side of the 

circuit under test or power line (earth) ground. Always make measurements with dry 

hands while standing on a dry, insulated surface capable of withstanding the voltage 

being measured. 
The instrument and accessories must be used in accordance with its specifications and 

operating instructions, or the safety of the equipment may be impaired. 
Do not exceed the maximum signal levels of the instruments and accessories, as defined 

in the specifications and operating information, and as shown on the instrument or test 

fixture panels, or switching card. 
When fuses are used in a product, replace with the same type and rating for continued 

protection against fire hazard. 

Chassis connections must only be used as shield connections for measuring circuits, 

NOT as safety earth ground connections. 
If you are using a test fixture, keep the lid closed while power is applied to the device 

under test. Safe operation requires the use of a lid interlock. 

 

If a screw is present, connect it to safety earth ground using the wire 

recommended in the user documentation. 

 

This symbol on an instrument means caution, risk of danger. The user should refer 

to the operating instructions located in the user documentation in all cases where 

the symbol is marked on the instrument. 

 

This symbol on an instrument means caution, risk of electric shock. Use standard 

safety precautions to avoid personal contact with these voltages. 

 

This symbol on an instrument shows that the surface may be hot. Avoid personal 

contact to prevent burns. 

 

This symbol indicates a connection terminal to the equipment frame. 

 

If the mercury symbol is on a product, it indicates that mercury is present in the 

display lamp. Please note that the lamp must be properly disposed of according to 

federal, state, and local laws. 

WARNING

  This heading in the user documentation explains dangers that might result 

in personal injury or death. Always read the associated information very 

carefully before performing the indicated procedure. 

CAUTION 

This heading in the user documentation explains hazards that could 

damage the instrument. Such damage may invalidate the warranty. 

Instrumentation and accessories shall not be connected to humans. 
Before performing any maintenance, disconnect the line cord and all test cables. 

Summary of Contents for 4200-SCS-PK3-903-01

Page 1: ...Model 4200 SCS PK3 Quick Start Guide...

Page 2: ...work on live circuits perform safe installations and repair products Only properly trained service personnel may perform installation and service procedures Keithley Instruments products are designed...

Page 3: ...in the specifications and operating information and as shown on the instrument or test fixture panels or switching card When fuses are used in a product replace with the same type and rating for cont...

Page 4: ...leaner directly to the instrument or allow liquids to enter or spill on the instrument Products that consist of a circuit board with no case or chassis e g a data acquisition board for installation in...

Page 5: ...users can begin analyzing their results sooner CD ROM contents The CD ROM that is included with your instrument contains Installation files for KITE These can only be installed on the Model 4200 SCS...

Page 6: ...dard accessories CD ROMs and optional accessories such as rack mount hardware 4 Remove the packaging insert 5 Remove the 4200 SCS from the bottom Do not lift the 4200 SCS from the front bezel Lifting...

Page 7: ...IV component test fixture with sample devices 3 Model 4200 RPC 2 remote PreAmp cables two 4 Model 4200 MTRX ultra low noise SMU triaxial cables four 5 Model 236 ILC 3 safety interlock cable 6 Model 42...

Page 8: ...dry locations Keithley Instruments Inc products are only rated for dry locations Read and comply with the specifications of all instruments in the system The overall allowed signal levels may be const...

Page 9: ...all safety warnings provided with each of the instruments in your system Install the instrument The Model 4200 SCS can be used on a bench or in a rack Please see the instructions that came with your...

Page 10: ...ow voltage fixtures such as the Model 8101 PIV that is included with this bundle are intended for applications that are less than 40 volts For these applications an interlock is not needed High voltag...

Page 11: ...ections for testing If you are testing discrete devices you need a test fixture that is equipped with 3 lug triaxial connectors The Model 8101 PIV test fixture that is included with the Model 4200 SCS...

Page 12: ...V Test section graphic Make connections for the C V test Power up the instrument The 4200 SCS operates from a line voltage of 100 V to 240 V at a frequency of 50 Hz or 60 Hz Make sure the operating v...

Page 13: ...of the power cord to a grounded AC outlet 4 Turn on the instrument by pressing the front panel POWER switch to the ON position The instrument starts up and loads the Microsoft Windows operating syste...

Page 14: ...Make connections for the I V test If you are using the supplied test fixture connect the MOSFET and test fixture as shown in this diagram...

Page 15: ...nMOSFET DUT 1 Plug into the test socket that is labeled DC ONLY 5 Model 8101 PIV Component Test Fixture 1 6 Model 4200 PA Remote PreAmp 2 7 Model 4200 SMU module 2 8 Model 4210 SMU module 2 Perform an...

Page 16: ...with the Model 4200 SCS PK3 you do not need to change these parameters Run the vds id test KITE can run a single test or a sequence of tests To run a single test check the test and click it The test...

Page 17: ...run In the following example only one test is run To run the vds id test 1 In the navigator double click the vds id test to highlight it and display the data sheets for the test 2 On the toolbar click...

Page 18: ...spreadsheets To view the results of the vds id test 1 Click the Sheet tab for the test 2 Select the tab below the data for the type of information you would like to view Data Displays the data Calc P...

Page 19: ...se Selected Sheets 4 Click OK To print the all sheets 1 Select File then Print 2 Choose Entire Workbook 3 Click OK To export the information 1 Open the worksheet that contains the data to be exported...

Page 20: ...ox and use different colors for the graph series These options are available through the Graph Settings button To customize a graph 1 Right click the graph The Graph Settings menu is displayed You can...

Page 21: ...4 Select the colors for each series 5 Click OK The series and color information is displayed...

Page 22: ...Make connections for the C V test If you are using the supplied test fixture connect the nMOSFET and test fixture as shown in this diagram...

Page 23: ...le 4 Model 8101 PIV Component Test Fixture 1 5 8101 309 nMOSFET with S D B connected together DUT 1 Plug into PULSE IV test socket 6 Model 4210 CVU Module 1 Perform a C V test on an nMOSFET 1 In the P...

Page 24: ...vice is connected to the CVH1 and the CVL1 terminals of the Model 4210 CVU The default setting shows the DC bias is swept from 5 V to 5 V in 0 2 V steps with a 1 MHz capacitance measurement taken at e...

Page 25: ...l is on 3 When the test is complete the Run Test button turns green View results of the cv nmosfet test To view data from the cv nmosfet test you can use the data sheets which are similar to Microsoft...

Page 26: ...se Selected Sheets 4 Click OK To print the all sheets 1 Select File then Print 2 Choose Entire Workbook 3 Click OK To export the information 1 Open the worksheet that contains the data to be exported...

Page 27: ...b for the test A sample graph is shown here In this example the C V curve is measured between the gate and the source drain bulk Notice that the COX CFB and VFB parameters are extracted and displayed...

Page 28: ...Model 4200 MTRX from the SMU The mini triaxial connector is a locking connector To remove it pull the knurled part of the connector back A configuration error has been detected and I cannot launch KIT...

Page 29: ...ic information about using the system plus application based examples that will help familiarize you with the instrument Model 4200 SCS Reference Manual Provides detailed information about all feature...

Page 30: ......

Reviews: