the equipment may be impaired. 

Do not exceed the maximum signal levels of the instruments and accessories, as defined in the specifications and operating 

information, and as shown on the instrument or test fixture panels, or switching card. 

When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard. 

Chassis connections must only be used as shield connections for measuring circuits, NOT as safety earth ground connections. 

If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use 

of a lid interlock. 

If a 

 screw is present, connect it to safety earth ground using the wire recommended in the user documentation. 

The 

 symbol on an instrument means caution, risk of danger. The user should refer to the operating instructions located in 

the user documentation in all cases where the symbol is marked on the instrument. 

The 

 symbol on an instrument means caution, risk of electric shock. Use standard safety precautions to avoid personal 

contact with these voltages. 

The 

  symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns. 

The 

 symbol indicates a connection terminal to the equipment frame. 

If this 

 symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp must be 

properly disposed of according to federal, state, and local laws. 

The 

WARNING

 heading in the user documentation explains dangers that might result in personal injury or death. Always read 

the associated information very carefully before performing the indicated procedure. 
The 

CAUTION

 heading in the user documentation explains hazards that could damage the instrument. Such damage may 

invalidate the warranty. 

Instrumentation and accessories shall not be connected to humans. 

Before performing any maintenance, disconnect the line cord and all test cables. 

To maintain protection from electric shock and fire, replacement components in mains circuits — including the power 

transformer, test leads, and input jacks — must be purchased from Keithley Instruments. Standard fuses with applicable national 

safety approvals may be used if the rating and type are the same. Other components that are not safety-related may be 

purchased from other suppliers as long as they are equivalent to the original component (note that selected parts should be 

purchased only through Keithley Instruments to maintain accuracy and functionality of the product). If you are unsure about the 

applicability of a replacement component, call a Keithley Instruments office for information. 

To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do not apply 

cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with 

no case or chassis (e.g., a data acquisition board for installation into a computer) should never require cleaning if handled 

according to instructions. If the board becomes contaminated and operation is affected, the board should be returned to the 

factory for proper cleaning/servicing. 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

11/07 

Summary of Contents for 2657A-LIM-3 LO

Page 1: ...Meter Instrument Model 4200 SCS Semiconductor Characterization System SMUs Model 4200 SMU Medium Power Source Measure Unit Model 4210 SMU High Power Source Measure Unit The Model 2657A LIM 3 creates a...

Page 2: ...nting A formed bracket and three long screws are supplied with the Model 2657A LIM 3 Use the bracket and screws to secure the protection modules to the top of the Model 2657A LIM 3 The screws should o...

Page 3: ...ck system on a bench or in a test fixture The flat mounting bracket is attached to the Model 2657A LIM 3 with three supplied flat head screws This mounting bracket can be attached to the Model 2657A L...

Page 4: ...arth Referring to the drawing below connect one lugged end of the Model CA 568 120 ground cable to the screw terminal on the Model 2657A LIM 3 and connect the other lugged end to protective earth safe...

Page 5: ...connected SMUs Power is routed through the Model 2657 LIM 3 to the the closed external switch to activate the interlock The Interlock voltage from the Model 4200 SCS is 12 V and the voltage from the o...

Page 6: ...Model 2657A SMUs 2 wire sensing D Three Model 2657A SMUs 4 wire sensing Required accessories The following table lists accessory quantities for each test configuration The connections for test config...

Page 7: ...2012 7 Connection summary Use the connection drawing below to connect Model 2657A source measure units SMUs to the test system The drawing shows connections for 4 wire sensing For 2 wire applications...

Page 8: ...Model 2657A LIM 3 LO Interconnect Module 8 PA 1063 Rev A March 2012 Figure 8 Connections using two Model 2657A SMUs...

Page 9: ...Model 2657A 2 wire sensing Accessory model D Model 2612A two channels Model 2657A 4 wire sensing 2657A PM 200 protection modules 1 1 2 2 CA 558 interlock cables 2 2 2 2 CA 573 3 interlock cable 1 1 1...

Page 10: ...10 PA 1063 Rev A March 2012 Do not convert triaxial cables to BNC cables Using BNC cables removes protection from the Model 2611A or 2612A and may result in damage to the SMU You must use triaxial ca...

Page 11: ...Model 2657A LIM 3 LO Interconnect Module PA 1063 Rev A March 2012 11 Figure 9 Connections using a Model 2657A and a Model 2611A or 2612A...

Page 12: ...ry model D Model 2636A two channels Model 2657A 4 wire sensing 2657A PM 200 protection modules 1 1 2 2 CA 558 interlock cables 2 2 2 2 CA 573 3 interlock cable 1 1 1 1 CA 568 120 ground cables 4 4 6 6...

Page 13: ...Model 2657A LIM 3 LO Interconnect Module PA 1063 Rev A March 2012 13 Figure 10 Connections using a Model 2657S and a Model 2635A or 2636A...

Page 14: ...B Model 4200 SCS SMU Model 2657A 4 wire sensing C Two Model 4200 SCS SMUs Model 2657A 2 wire sensing Accessory model D Two Model 4200 SCS SMUs Model 2657A 4 wire sensing 2657A PM 200 protection modul...

Page 15: ...s are not used for 2 wire applications When using multiple SMUs that are installed in the Model 4200 SCS each SMU needs its own protection module To achieve adequate voltage protection connect the GND...

Page 16: ...Model 2657A LIM 3 LO Interconnect Module 16 PA 1063 Rev A March 2012 Figure 11 Test system connections using a Model 2657A and a Model 4200 SCS SMU...

Page 17: ...all measurement control and data I O connections are for connection to Category I sources unless otherwise marked or described in the user documentation Exercise extreme caution when a shock hazard i...

Page 18: ...explains dangers that might result in personal injury or death Always read the associated information very carefully before performing the indicated procedure The CAUTION heading in the user documenta...

Reviews: