ANALOG CONTROL
105
Connection- alt.
shielding
If the wire shield needs to be grounded at the
voltage source (EXT-V), then the shield cannot
also be grounded at the negative (-) terminal
output of the 2260B power supply. This would
short the output.
Power
supply
EXT-V
Analog
connector
+
-
16
5
Output
Terminal
2 core shielded
wire or twisted
pair
Pin16
→
EXT-V (-)
Pin5 →
EXT-V (+)
Wire shield →
EXT-V ground (GND)
Steps
1.
Connect the external voltage according to the
connection diagrams above.
2.
Set the F-91 power on
configuration setting to 1 (CC
control
–
Ext voltage).
Page 96
Be sure to cycle the power after the power on
configuration has been set.
3.
Press the Function key and confirm
the new configuration settings (F-
91=1).
4.
Press the Output key. The current
can now be controlled with the