Keyboard overview 

The keyboard of Series 2230G power supplies is shown in the following 
figure. 

 

 

Key descriptions: 

 Select channel 1. 

 Select channel 2. 

 Select channel 3. 

  Set the voltage limit for the selected channel. 

  Set the current limit for the selected channel. 

  Open the menu to access various Series 2230G settings. 

 

  Turn the output of all enabled channels on or off. When you turn 

on the output, the CC or CV indicators are visible on the display. When 
you turn off the output, the SV indicators are visible on the display. SV 
indicates that the display is showing each channel’s programmed settings. 

  through 

  numeric keys. Enter numbers to set values. 

  Return to the previous menu level. 

  Use left and right arrow keys to move the cursor. 

Use up and down arrow keys to adjust the parameters or select an 
item in the menu. 

  Save the present settings as a saved setup. The Series 2230G 

supports up to 36 saved setups. 

  Return the instrument to a specified setup. 

  Select a menu item or confirm an operation. 

Summary of Contents for 2230G-30-3

Page 1: ...Series 2230G Triple Channel DC Power Supply Quick Start Guide...

Page 2: ...ple setting the line voltage orreplacing consumablematerials Maintenance procedures are described in the user documentation The procedures explicitly state if the operator may perform them Otherwise t...

Page 3: ...removing switching cards or making internal changes such as installing or removing jumpers Do not touch any object that could provide a current path to the common side of the circuit under test or po...

Page 4: ...ed fromKeithleyInstruments Standard fuses with applicable national safety approvals may be used if the rating and type are the same The detachable mains powercord provided with the instrument may only...

Page 5: ...m 6562 ft above sea level Operating temperature 0 C to 40 C 32 F to 104 F full accuracy with maximum 80 relative humidity at up to 40 C 104 F non condensing Storage temperature 20 C to 70 C 4 F to 15...

Page 6: ...voltage or current of each channel can be set from 0 to the maximum value You can set and display the voltage and current of three channels at one time without switching greatly simplifying the operat...

Page 7: ...eport any damage to the shipping agent immediately You should have received your 2230G 30 3 2230G 30 6 or 2230G 60 3 power supply with the following accessories Calibration certificate part number 001...

Page 8: ...gation wheel to increase or decrease a value or to scroll through the menus after pressing the Menu key When you have selected the menu item or value you want press the Enter key to save your setting...

Page 9: ...visible on the display When you turn off the output the SV indicators are visible on the display SV indicates that the display is showing each channel s programmed settings through numeric keys Enter...

Page 10: ...hown in the figure below Descriptions of the numbered items follow the figure Number Description 1 Vent and fan 2 RS 232 communication interface 3 USB communication interface 4 GPIB communication inte...

Page 11: ...n displays the voltage settings of all three channels The second line on the home screen displays the current settings of all three channels The SV indicator informs the user that the display is showi...

Page 12: ...ture connected to the system protects the operator from contact with hazardous voltages hot surfaces and sharp objects Use shields barriers insulation and safety interlocks to accomplish this Cover th...

Page 13: ...and airflow around the instrument to ensure proper cooling Do not cover the ventilation holes on the top sides or bottom of the instrument Make sure the instrument is positioned so that it is easy to...

Page 14: ...h inadequately rated cords Failure to use properly rated cords may result in personal injury or death due to electric shock When using the Model 2230G 30 6 or 2230G 60 3 in a country that is a member...

Page 15: ...ram 1 Make sure that the front panel power switch is in the off 0 position 2 Properly set the 110 V 220 V selector switch on the bottom of the instrument 3 Connect the female end of the supplied line...

Page 16: ...used for basic operations when maximum precision is not required Keep the wire as short as possible to reduce wire resistance If you want higher measurement precision use a remote sense connection To...

Page 17: ...Leave remote sense wires connected even when remote sense is not used Disconnecting the remote sense wires will cause erratic behavior and may damage the power supply DUT...

Page 18: ...from to S and to S 2 Connect the S to the positive terminal of the DUT and connect the S to the negative terminal of the DUT as shown in the following wiring diagram To ensure the stability of the sy...

Page 19: ...limit 1 Select the channel by pressing the CH1 CH2 or CH3 key 3 Use the numeric keys the navigation wheel or the up down right and left arrow keys to set the current limit 4 Press Enter to confirm the...

Page 20: ...a one to one ratio is maintained and any voltage change on channel 1 results in a corresponding change on channel 2 If channel 1 is set to 10 V and channel 2 is set to 5 V when tracking is turned on...

Page 21: ...outputs of the channels You can only set CH1 and CH2 of the 2230G 30 3 and 2230G 30 6 to series operation mode You can set CH1 and CH2 CH2 and CH3 or all three channels of all models to parallel oper...

Page 22: ...onnect the channels are too small too long or improperly tightened accuracy of measurements will be adversely affected To combine channel 1 and channel 2 when the outputs are wired in parallel 1 Conne...

Page 23: ...he combine function 1 Remove all connections to the output terminals 2 Press the Menu key 3 Use the arrow keys to select Combine 4 Press the Enter key 5 Press the down arrow key to select Combine Off...

Page 24: ...y does not read the voltage or voltages I have set 1 Make sure that the rear panel mating connector with the shorting jumpers is inserted into the rear panel when using the front panel connectors and...

Page 25: ...information refer to the Series 2230G User s Manual It provides detailed information about all features of the instrument You can also visit tek com keithley for support and additional information ab...

Page 26: ......

Reviews: