Series 2230G Triple-Channel Power Supplies User's Manual
Section 5: SCPI command reference
2230G-900-01 Rev. A / June 2018
5-19
Example
INST:COMB:PAR CH1CH2
Specifies that the instrument combine the present readings on channel 1 and channel 2 when they
are in parallel operation mode.
See also
(on page 5-18)
INSTrument:COMBine:SERies
This command combines the present voltage readings on channel 1 (CH1) and channel 2 (CH2) when they are
connected in series.
Group
Channel
Syntax
INSTrument:COMBine:SERies
Arguments
None
Default value
Not applicable
Returns
Not applicable
Example
INST:COMB:SER
Specifies that the instrument combine the voltage readings of channel 1 and channel 2 when
connected in series.
See also
(on page 5-18)
INSTrument:COMBine:TRACk
This command sets channels to tracking mode.
Group
Channel
Syntax
INSTrument:COMBine:TRACk {CH1CH2|CH2CH3|CH1CH2CH3}
Arguments
CH1CH2|CH2CH3|CH1CH2CH3