20
DOC06340 Rev. I
OWNER / OPERATOR MANUAL
RUNNING FLOOR II
®
DX-i
4.3 Bolt Torque Requirements
Description
Size
Quantity
Torque Values
Tube Clamps
M6 CL8.8 HCS
1/4 in GR5 HCS
Varies
Snug
Check Valve &
Adapter Block Bolts
M8 CL12.9 SHCS
5/16 in A574 SHCS
4 per valve/block
27 N·m
20 ft-lbs]
Control Valve
M10 CL10.9 HCS
3/8 in GR8 HCS
1
61 N·m
[45 ft-lbs]
Switching Valve Bolts
M10 CL10.9 HCS
3/8 in GR8 HCS
3
61 N·m
[45 ft-lbs]
Cylinder Rod End Bolts
(Requires anti-seize LB8060)
M16 CL10.9 HCS
5/8 in GR8 HCS
8 per cylinder
183 N·m
[135 ft-lbs]
Barrel Clamp Bolts
M16 CL10.9 HCS
5/8 in GR8 HCS
4 per cylinder
183 N·m
Max **
[
135 ft-lbs
] Max **
Floor Bolts (Flat Head)
M8 CL10.9 FHCS (90°)
5/16 in GR8
F
HCS (82°)
Varies
27 N·m
[20 ft-lbs]
* Bolts installed using thread lock should be checked using a setting that is 7 N·m [5 ft-lbs] less than
the above specified value. If the bolt moves then you should remove it, clean it, apply new loctite to
the threads and torque it to the full
specified value.
** Over tightening the barrel clamp bolts can deform the cylinder barrel shape causing the system to
not function properly.
Check Valve &
Adaptor Block
Bolts (x24)
Cylinder Barrel
Clamp Bolts (x12)
Cylinder Rod
End Bolts (x24)
Switching Valve
Bolts (x3)
Control Valve
Bolt (x1)
Tube Clamp
Bolts
9907201