13
4.4 Hydraulic tubing
Section 2.3 discusses the location of hydraulic tubing.
IMPORTANT:
All components and tubing must be kept absolutely clean to prevent dirt
from entering the system.
1. Determine tube locations and lengths.
2. Cut tubes to length.
3. Position tubes.
Use the weld on tube clamps supplied with the kit or use rubber grommets or PVC
tubes to protect the tubing when installing tubes through cross-members
4. Connect tubes to drive unit.
Connect the pressure line to outside line that is connected to the switching valve
port labeled “PUMP” and return line to inside line that is connected to the
switching valve port labeled “RES”.
5. Mount quick couplers just inside front of container.
Connect the male coupler on the pressure line (outside line to switching valve
port stamped “pump”). Connect the female coupler to the return line (inside line to
switching valve port stamped “res”) (Figure 14). Apply hydraulic sealant.
DETAIL A
SCALE 1 / 40
SECTION H-H
A
H
H
Weld on
tube clamps.
Pressure Line
Male Coupler
Return Line
Female Coupler
After Drive Unit is welded
in place attache Hydraulic
Oil lines.
Front
of
Container
75370
Figure 14