background image

03

INSTALLATION INSTRUCTIONS

TRIPLE TRAINER

IMPORTANT SAFETY INFORMATION

1 559 256 8000

[email protected]

keiser.com/support

Telephone and Live Chat 
Monday—Friday 9 am to 5 pm PST

CUSTOMER SUPPORT

If you do not understand these instructions or have doubts about the safety of the installation, assembly, or use of this product, 

contact Keiser Customer Support:

1.        Read these instructions.
2.  Heed all warnings.
3.  Follow all instructions.
4. 

Professional installation is required by qualified personnel as dictated by authority having jurisdiction.

5.  Proper installation is the responsibility of the installer.
6.  Product failure due to improper installation is not covered under warranty.
7.  It is the responsibility of the facility owner to adhere to local and regional building codes.
8.  Follow all safety and installation instructions of the anchor and adhesive manufacturers.
9. 

Equipment must be mounted on level, solid concrete floor, minimum 5 inches (127 mm) thick. 

10. 

All anchors must have a minimum embedment in concrete, regardless of any rubber/carpet/artificial  turf,  including 
underlayment covering the concrete. If mounting the equipment over floor covering, use appropriate length screw anchors 
(not supplied), along with the steel spacers provided, to bridge any gap between the concrete floor and the Floor Mount Plate.

11.  Wear appropriate personal protective equipment (PPE); observe all governing codes and ordinances.
12.  Safety Glasses required during installation.
13.  Use a dust collection system when drilling; clean area using a HEPA vacuum. Avoid breathing dust.
14. 

Heavy Equipment: The Floor-mounted Triple Trainer weighs 350 lbs (159 kg). Help is required when handling the Triple 
Trainer to prevent potential muscle strain and/or back injury.

15.  Crush Hazard: Keep feet clear when handling the Floor Mount Plate and/or the Functional Trainer.
16.  Never connect Keiser pneumatic equipment to an air source that is capable of exceeding 120 pounds per square inch (psi) 

/ 8.27 bar. Over pressurizing Keiser pneumatic equipment may cause tubing to burst, breakage of equipment, abnormal 
operation, or serious injury. Use only clean, dry, regulated compressed air at the rated pressure range of 100–120 psi / 
6.89–8.27 bar.

17.  It is the responsibility of the facility owner or the owner of the Triple Trainer to instruct users on the safe and proper 

operation of the equipment.

CONVENTIONS USED

This Installation Instruction contains the following marks:

WARNING: 

Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

WEAR SAFETY GLASSES:

 Safety glasses required during the procedure.

CRUSH HAZARD: 

Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

HEAVY EQUIPMENT: 

Indicates help is required during lifting to avoid muscle strain and/or back injury.

IMPORTANT: 

Indicates information considered critical, but not hazard-related.

Summary of Contents for INFINITY 3020XA

Page 1: ...or operation of the Triple Trainer after reading this manual contact Keiser Customer Support 1 559 256 8000 service keiser com keiser com support Telephone and Live Chat Monday Friday 9 am to 5 pm PS...

Page 2: ...LS AND MATERIALS 06_UNPACKING 07_PARTS LIST 08_STEP BY STEP INSTALLATION GUIDE 11_AIR SYSTEM SETUP FINAL INSTALLATION 11 BEFORE YOU USE THE TRIPLE TRAINER This equipment contains electrical or electro...

Page 3: ...ive equipment PPE observe all governing codes and ordinances 12 Safety Glasses required during installation 13 Use a dust collection system when drilling clean area using a HEPA vacuum Avoid breathing...

Page 4: ...Length may vary based on Accessory type user height and the position setting of the exercise Arm To safely and effectively use your Training Space remember to 1 Clear your Training Space Ensure there...

Page 5: ...TION OPTIONS ANCHORING Equipment must be installed with the Floor Mount Plate Use all four anchor holes on the Floor Mount Plate to secure the equipment Follow all safety and installation instructions...

Page 6: ...area has been planned according to the training space required refer to the Training Space section page 4 UNPACKING Figure 3 Unpacking the Triple Trainer Safety Glasses High Quality Floor Wall Scanne...

Page 7: ...8Cx1 8M in 8078 11 3 Male Quick disconnect QD 110897 12 1 Air Tube with Luer and Quick Disconnect 953108 8086 110897 13 12 Washer 3 8 in 9355 14 12 Screw 3 8 16x3 4 in 9200 15 6 Screw 1 4 20x3 8 in 9...

Page 8: ...installation is similar DRILL USING THE FLOOR MOUNT PLATE AS THE DRILL PATTERN QUANTITY 3 DRILL HOLES IMPORTANT Check the Floor Mount Plate alignment as each hole is drilled to avoid costly rework CO...

Page 9: ...Anchor through the Floor Mount Plate and into the drill holes Tighten the Screw Anchors into the concrete until the hex washer head contacts the surface of the Floor Mount Plate Immediately remove an...

Page 10: ...for the remaining two Brackets B A 7 Remove x2 1 4 20x1 4 in Phillips Screws BRACKET INSTALLATION PREPARATION Remove the top two 1 4 20x1 4 inch Phillips Screws along the sides of the Functional Train...

Page 11: ...the Compressor into a power source to power the Compressor ON Allow the Compressor to build up to a minimum of 100 psi 6 89 bar POWER ON THE EQUIPMENT Press the and then the Thumb Buttons a few times...

Page 12: ...uestions regarding the installation or operation of the Triple Trainer after reading this manual contact Keiser Customer Support 305522_B 1 559 256 8000 service keiser com keiser com support Telephone...

Reviews: