KegLand RAPT Pill Quick Start Manual Download Page 18

RAPT Pill Hydrometer & Thermometer Quick Start Guide 

 

Page 

18

 of 

18 

www.KegLand.com.au

 

Last Updated 6/05/2022 16:49 PM

 

 

Warranty (Australia) & Support 

Please join the Facebook 

RAPT Users Group

 for support on how to use your RAPT Pill & 

Thermometer or the RAPT Portal. 

If you need hardware support, please contact your nearest distributor. 

The RAPT Pill & Thermometer comes with a 12-month warranty when sold in Australia. To lodge a 
warranty claim in Australia please forward as many visual pieces of supporting information and a 
detailed description of your issue to  

If you purchased your unit from an international distributor, you will be required to go through their 
warranty claims process. 

For a full terms and condition please visit our website here -

Terms & Conditions

 

Summary of Contents for RAPT Pill

Page 1: ...APT Pill Hydrometer Thermometer Quick Start Guide Page 1 of 18 www KegLand com au Last Updated 6 05 2022 16 49 PM RAPT PILL Hydrometer Thermometer KL20596 Quick Start Guide KegLand Distribution PTY LT...

Page 2: ...vanced Calibration 11 3 Custom Calibration 12 Updating Firmware 14 Trouble shooting Registration and Telemetry 15 Green light is not illuminating when RAPT Pill plugged in to USB C 15 Red battery ligh...

Page 3: ...KegLand approved cleaners such as StellarOxy and StellarClean and sanitisers such as StellarSan or Phosphoric Acid Battery Installation The battery will come pre installed in the RAPT Pill with a non...

Page 4: ...ure your battery has good contact with the terminals After installing the battery rotate it slightly within the battery holder to ensure it has good contact Important Once you have installed the Li io...

Page 5: ...Fully Charged ESP LED GREEN Slow Green Flashes flashes when the captive portal is enabled and the Pill is searching for a Wi Fi network This will happen when the Pill is plugged in to USB C the first...

Page 6: ...l Captive Portal If you are not prompted to sign into the network of your RAPT Pill by your smart phone or tablet then open your Wi Fi settings and select the RAPT Pill XXXX Wi Fi network again to ope...

Page 7: ...n be used to access the Pill AP in a browser 2 Ensure you are logged in to the RAPT Portal https app rapt io on a second device that is connected to the same home Wi Fi network as the Pill you are reg...

Page 8: ...ortant to insert the circuit board in the correct orientation to ensure the correct weight distribution for accurate readings The yellow end of the circuit board should be inserted into the yellow hou...

Page 9: ...on such as if you are fermenting in a fermentation chamber place the Pill in a jug in the fermentation chamber to confirm that telemetry is received and your RAPT Pill has good signal strength 2 Once...

Page 10: ...ngs and select the RAPT Pill XXXX Wi Fi network again to open the Pill Captive Portal 3 Once the RAPT Pill Access Portal is open on your phone or tablet navigate to the Calibration tab 4 Select the de...

Page 11: ...tion is also quite quick and easy and can provide a more accurate result than Standard Calibration It is the same procedure as standard calibration but in addition to water at 1 000 have a solution of...

Page 12: ...e gravity readings 1 Place the Pill in the first solution of known gravity Wait for the angle to stabilise then make a note of the angle and the gravity 2 Repeat this step for solutions of different g...

Page 13: ...o this y 0 0000023109x5 0 0005741632x4 0 0568746764x3 2 8119846525x2 71 1087310405x 265 6578215178 This is a sample only DO NOT USE THIS EQUATION AS IT WILL NOT BE ACCURATE Substitute x in this equati...

Page 14: ...ur phone or tablet or through the Pill IP address 1 Plug your Pill in to USB power with a USB C cable 2 Connect to the Pill Access Portal with your phone or tablet or through the Pill IP address 3 Nav...

Page 15: ...e Pill stop flashing shortly after it is unplugged This is normal behaviour There is an approximately 10 minute timeout after the Pill is unplugged There are no lights on the Pill when unplugged This...

Page 16: ...o 30dBm Maximum signal 50dBm Excellent signal 67dBm Good reliable signal 70dBm Ok not a strong signal 80dBM Poor unreliable signal 90dBM Unusable Re Register Your RAPT Pill If your RAPT Pill is still...

Page 17: ...perating level the Pill will enter a deep sleep mode in order to protect the battery There may have been an interruption to the network or internet The battery may be slightly loose in the terminals c...

Page 18: ...support please contact your nearest distributor The RAPT Pill Thermometer comes with a 12 month warranty when sold in Australia To lodge a warranty claim in Australia please forward as many visual pie...