Step 4. To adjust the Filling Process time parameters press 

Filling Station

 and then press 

Set. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for KL25959

Page 1: ...64 Cannular Fully Automatic Single Lane Page 1 of 9 www KegLand com au Last Updated 25 05 2023 14 27 PM Quick Start Manual Keg Washing Filling Machine KL25959 KegLand Distribution PTY LTD www KegLand com au ...

Page 2: ...tents Wiring 3 Specifications 3 Keg Washing Procedure 3 Keg Filling Procedure 3 CIP Procedure 3 Pressure Adjustments and Air Pressure Regulator Maintenance 3 Adjustment of Pneumatic Cylinder Actuation Speed 4 Operation and General Maintenance 4 Common Faults and Troubleshooting 5 PLC Time Parameter Adjustments 5 ...

Page 3: ...ycle Steam Sterilisation Water Wash Water Recycle CO2 Purge CO2 Pressurise Keg Filling Procedure For commercial stainless steel kegs the following filling procedure is followed Load the Keg Keg Coupling CO2 Pressurise Filling CO2 Blow of Filling Heads Stop Unload Keg When filling PET kegs make sure to close the needle valve of the cylinder CIP Procedure Connect CIP Liquid to Beer Inlet Install Was...

Page 4: ...er tank will automatically shut off once the float valve has reached its raise position Water will be automatically replenished into the hot water tank as required 2 Open the inlet of the caustic tank and close it when the level reaches 15 20mm to the caustic tank Dispense the caustic for use 3 Invert the keg and place onto the washing head 4 Perform a final check before starting the keg washing p...

Page 5: ...spear Adjust seal ring Power Failure Voltage exceeds the working limit of PLC Inspect input Power Short circuit Inspect Circuit Indicator Lamp not working Lamp is damaged Replace Lamp Residual beer in keg after washing Washing time is too short Adjust time on PLC Extractor tube damaged Inspect tube for damage and replace if required Low Filling Speed Retain Valve pressure is too high Adjust pressu...

Page 6: ...ast Updated 25 05 2023 14 27 PM Step 1 Press Set A Login popup will then be shown as below Step 2 Input 123 as the User and 8760 as the password Then press enter which will return you to the keg washing process page Step 3 Press Set to adjust the washing process time parameters ...

Page 7: ...KL25164 Cannular Fully Automatic Single Lane Page 7 of 9 www KegLand com au Last Updated 25 05 2023 14 27 PM ...

Page 8: ...KL25164 Cannular Fully Automatic Single Lane Page 8 of 9 www KegLand com au Last Updated 25 05 2023 14 27 PM Step 4 To adjust the Filling Process time parameters press Filling Station and then press Set ...

Page 9: ...ane Page 9 of 9 www KegLand com au Last Updated 25 05 2023 14 27 PM Step 4 Adjust the Washing process time parameters as required If you do not need any of the processes to function then set its time value as 00 0 sec USER ID 123 PASSWORD 8760 ...

Reviews: