IMPORTANT SAFETY INFORMATION

1.

 

You must read and follow all instructions. 
Serious bodily injury or death could occur if 
you ignore this warning. 

2.

 

All circuit breakers and/or disconnect switches 
servicing the HOT DRAFT® Tower must be 
turned off when installing, uninstalling, or 
repairing this unit. 

3.

 

The Tower must be installed by a licensed 
electrician.  

4.

 

The Tower must be wired in accordance with 
the current version of the National Electrical 
Code (US) or Canadian Electric Code (Canada). 

5.

 

This installation must comply with all national, 
state, and local plumbing and electrical codes. 

6.

 

When the Tower is not within sight of the 
electrical circuit breakers, an additional local 
means of disconnection of all ungrounded 
conductors must be provided that is within 
sight of the appliance or a circuit breaker 
lockout must be used. (Ref. NEC 422.31) 

7.

 

If the Tower is installed in a location where 
liquid damage could occur in the event of a 

leak, it is recommended that a drip pan be 
installed and connected to a suitable drain.  

8.

 

This is a closed system meaning that the 
product is coming from a container under 
pressure or from a vacuum system of delivery. 
Adhere to the labeling requirements on the 
containers regarding allowable pressure and/ 
or delivery recommendations so that system is 
not compromised.  

9.

 

Product containers such as kegs, bag-in-box, or 
other types of product packaging each come 
with guidelines as to maximum pressure 
allowed or recommended delivery instructions 
required for safe handling. It is imperative that 
operator follow these guidelines at all times! 

10.

 

This Tower must be installed in a location 
where it is not subject to freezing 
temperatures unless supplied with factory 
installed freeze protection. 

11.

 

This Tower is not rated for outdoor use. This 
Tower must be installed indoors to function as 
intended. 

Beverage Factory 

Phone: 1-(800) - 710-9939

 

 

 

Summary of Contents for Hot Draft KC HDT301

Page 1: ...USER MANUAL Model KC HDT301...

Page 2: ...L SPECIFICATIONS 6 PRODUCT FEATURES 6 PARTS DIAGRAM 7 NAVIGATING YOUR HOT DRAFT TOWER 8 Accessing the Service Menu 8 SETPOINT 8 PURGE 9 CLEAN 9 FLOW PWM IN OUT VERSION 9 COMP 9 POURING WITH YOUR HOT D...

Page 3: ...oupling the keg so that pressure is eliminated during the cleaning inspection THIS PRODUCT SHOULD BE INSTALLED BY A LICENSED ELECTRICIAN AND A QUALIFIED PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE P...

Page 4: ...reaker lockout must be used Ref NEC 422 31 7 If the Tower is installed in a location where liquid damage could occur in the event of a leak it is recommended that a drip pan be installed and connected...

Page 5: ...at its original maximum quality without the degradation of heretofore constant reheating What does this mean The HOT DRAFT Tower delivers constant freshness with zero waste Inside the keg nitrogen is...

Page 6: ...8 kW 240 V 60 Hz 20A 4 4 kW 230 V 60 Hz 20A 3 6 kW 208 V 60 Hz 18A Operating Pressure Range Optimal Operating Pressure Range 20 PSI 40 PSI 25 PSI 35 PSI Minimum Flow Rate 0 15 GPM Minimum Maximum Inl...

Page 7: ...4 Outlet Thermistor 5 ECO Electrical Cutoff 6 Heating Chamber 7 Inlet Manifold 8 Triac 9 Inlet Thermistor 10 Hall Effect Sensor 11 Flow Meter 12 Inlet Screen 13 Inlet Barbed Nipple for 3 16 ID Tubing...

Page 8: ...exit the Service Menu you must navigate to either the FLOW PWM IN OUT or VERSION screens and press SEL You cannot exit the Service Menu from the SETPOINT PURGE or CLEAN screens SETPOINT SETPOINT will...

Page 9: ...aft faucet to run your cleaning solution through the Hot Draft lines Pressing SEL will return you back to the service menu FLOW PWM IN OUT VERSION FLOW displays the flow rate of the Hot Draft line dis...

Page 10: ...beverage 1 Before Pouring your first cup you must purge the Hot Draft Tower Failure to do so may cause hot water to splash on the first pour Navigate to the Purge setting in the Service Menu and turn...

Page 11: ...ep the faucet open while the unit is heating the beverage The Hot Draft Tower may drip out underheated beverage during heating This is normal keep a mug under the Hot Draft faucet to catch these drips...

Page 12: ...erage is pouring accurately to the setpoint temperature For a 208V electrical system we recommend tuning the Compensation Factor between 10 18 Flow Rate Fine tuning the Flow Rate may be required if th...

Page 13: ...FORE REMOVING LID AND REACHING INSIDE FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH To remove the lid use a Philips head screwdriver to remove 4 screws circled in red below Flow rate is adjus...

Page 14: ...shown below After adjusting the flow adjustment spindle check the flow rate by plugging in the unit navigating to FLOW in the service menu and opening the hot beverage faucet to pour a beverage Adjust...

Page 15: ...raft heating components from potent acids found in this product To clean lines used to dispense beverages such as beer or kombucha we recommend Kegco Beer Line Cleaner This solution will remove organi...

Page 16: ...cting to a dispense system Some disassembly may be required 4 Place a bucket or pitcher under the faucet corresponding to the beverage line connected to your cleaning container Open the faucet and all...

Page 17: ...omer service Underheated Inconsistent Beverage Pour The unit is not supplied with enough voltage Verify power supply voltage Ensure DIP Switches are correctly configured as shown in section Electrical...

Page 18: ...ressed or implied whether written or oral including but not limited to warranties of merchantability and fitmess for a particular purpose Kegco expressly disclaims the implied warranties of merchantab...

Page 19: ...control o The product has been removed from its original installation location o The product has been used for other than the intended purpose The original owner and not Kegco or its agent representa...

Reviews: