background image

20

21

Combined movie and music setup.

The Reference Series 209 subwoofer can be used
for both main speaker low frequency extension
and the LFE channel reproduction for a surround
sound system.

Set the subwoofer up as described in section
‘Music Only Setup’. With the subwoofer
correctly set up for stereo use, connect the LFE
output from your surround processor to the LFE
input of the subwoofer. Without making any
adjustments to the subwoofer’s controls,
including the volume level, follow the set-up
procedure on your surround processor to adjust
the subwoofer volume level (as described in
section ‘Movie Only Setup’).

Finally, separate EQ presets can be applied for
both the stereo and LFE inputs (as detailed in
‘Preset Equalization options’, page 22).

Connecting to the speaker inputs (high level).

Speaker level or line level inputs are available to
allow flexibility in set-ups for the Left and Right
inputs. The specific LFE input is line level only to
interface with an A/V processor.

The speaker input terminals will accept bare
wire, spade or 4mm connectors. Most good
quality loudspeaker cables have some indication,
such as colour coding or ‘ribbing’ on the
insulating material, indicating which conductor is

+

’ or positive. Connection to the subwoofer can

then be made as follows:

The left channel amplifier output terminal marked

+

’ or coloured RED connects to the left

subwoofer speaker input terminal marked ‘

+

’. 

The left channel amplifier output terminal marked

-

’ or coloured BLACK connects to the left

subwoofer speaker input terminal marked ‘

-

’.

Similarly, these instructions should be followed for
making connections between the right channel
amplifier output and the right subwoofer speaker
input terminals. Correct polarity, or phase, is vital
to the proper operation of the system.

Bare wire connections are the simplest to
achieve and involve stripping 12.5mm (1.2in.) of
insulation to expose the loudspeaker wire core.
(You should twist together, using clean fingers,
the ends of each multi-stranded core prior to the
next stage to ensure a good signal contact).
Having unscrewed the lower terminal cap, push
the wire through the exposed hole in the
terminal body and screw the cap down tightly.
Make sure that no stray strands come into
contact with the opposite terminal; this could
cause a short circuit between the terminals and
may damage your amplifier.

KEF recommends that high quality loudspeaker
cable be used for connecting to your Reference
Series Model 209 subwoofer high level inputs. 
It is good practice to keep the cables as short 
as possible.

Be aware that a higher quality run of cable will
always give a more rewarding presentation than
multiple runs of an inferior cable.

Poor quality cables can seriously compromise the
overall sound of your hi-fi system.

Movie only setup through the LFE input.

This dedicated line level input is specifically for
the LFE (Low Frequency Effects) output from a
surround sound A/V processor. Please note that
single ended (phono) or balanced (XLR)
connections are available, however, they must
not be used simultaneously. The LFE input to the
subwoofer will not be affected by the frequency
or slope settings which apply only to the Left and
Right channel line inputs.

Once your subwoofer is connected and powered
up it needs to be integrated into your home
cinema system. To do this you will need to follow
the set-up procedure for your surround sound
processor. Set the subwoofer volume to 50 and
the phase to 0. In the surround sound
processor’s speaker menu, ensure that the
subwoofer is set to ‘on’. If using smaller satellite
speakers then set the speaker size to ‘small’. KEF
would recommend starting with the ‘small’
setting if you are unsure. 

If you are using full range speakers set the
speaker size to ‘large’. Use the processor’s
controls to adjust the level of the subwoofer 
at the same time as setting each of the 
channel levels.

Music only setup through the Left/Right inputs.

To increase the low-frequency extension of your
existing stereo speakers connect the amplifier’s
line level outputs to the subwoofer Left and Right
line level inputs. If line level outputs are not
available then connect the Left and Right amplifier
speaker outputs to the speaker inputs of the
subwoofer. Once the subwoofer is connected and

the power is switched on it needs to be
acoustically integrated into your existing system.
To do this you will need to use the volume,
frequency and phase controls on the subwoofer’s
remote control. The remote control allows you
to do this whilst seated in your normal 
listening position.

First select the subwoofer low-pass filter slope
to match your main speakers. For a bass reflex
design speaker the slope should be set to
24dB/octave. This applies to all the KEF
Reference Series loudspeakers. For a closed box
loudspeaker, however, the slope should be set to
12dB/octave.

Select a piece of music that you are familiar with
which has a constant, repetitive bass line. 
Start with the level and frequency controls at the
middle positions and the phase control set to 0.
Adjust the level control until you are happy with
the low frequency levels when compared with
the main speakers. Now adjust the frequency
control so that there is no obvious change in the
level of the sound from very low frequencies to
higher frequencies. Adjust the polarity and the
phase control to achieve the smoothest
integration between the subwoofer and the main
speakers. KEF recommend you take some time
making fine adjustments to the controls, whilst
listening to a varied selection of music, until you
are satisfied with the sound balance.

Once finished it is worth pressing and holding an
available preset so that all the current settings
are saved into that preset. These settings can
then be recalled at any time by pressing the same
preset button.

K7262 REF 209208 Combined Manual_v2  12/2/08  12:40  Page 20

Summary of Contents for REFERENCE 209

Page 1: ......

Page 2: ... on top of this apparatus Do not install near any heat source such as radiators stoves or other appliances that produce heat Ensure that the power plug and cord are correct for your sockets Do not use if they show any signs of damage This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 this device does not cause harmful interference and 2 this devic...

Page 3: ... use To completely disconnect the apparatus from supply mains the plug must be removed from the mains socket outlet completely Important Safety Instructions Important Information Thank you for purchasing this KEF Reference Series subwoofer It has been designed to faithfully reproduce high quality sound over many years of use Please take a little time to read these instructions prior to use Your KE...

Page 4: ...ol and Control Functionality 16 Connections Setup and Fine tuning 18 connection diagrams movie only setup through the LFE input music only setup through the Left Right input combined movie and music setup connecting to the speaker inputs high level Using the Preset Equalization options 22 Using the Room Correction facility 23 Grille 24 Warranty 24 Service Information 24 Specifications 25 Reference...

Page 5: ...sure is beautiful on the outside and highly technical on the inside Attached to the inner surface are 30 ACE modules tubes of activated carbon which increase the effective internal acoustic volume by a factor of 2 ACE technology see page 8 is KEF s solution to the oldest catch 22 in loudspeaker design that to get good bass extension with good efficiency you need a large enclosure The Reference Ser...

Page 6: ...ules In fact the bass quality of ACE loaded enclosures is consistently admired by audiophiles for its clarity and detail Room Correction The listening room has a major impact on the sound of loudspeakers particularly at low frequencies In this region standing wave resonances in the room result in large peaks and dips in the loudspeaker response It is very difficult to compensate for the effect of ...

Page 7: ...F care pack is included with the subwoofer This pack contains a cleaning cloth and all the required accessories for connecting and positioning your Accessories sunlight should if possible be avoided Furthermore the cabinet should not be allowed to become wet Each Reference Series 209 subwoofer is supplied with KEF designed substantial spikes and locking nuts also in the care pack This enables fine...

Page 8: ...is is where the room correction feature on the Reference Series 209 subwoofer becomes such an important feature As the sub bass low frequency sound produced by the subwoofer is close to omni directional positioning of the subwoofer is less critical than with full range conventional speakers However it is advised that the subwoofer is not positioned too close to the listener It is often recommend t...

Page 9: ...mplifier and the KEF Reference Series 209 subwoofer or use the Line level LFE input described below Line input LFE This dedicated line level input is specifically for LFE Low Frequency Effects output from a surround sound processor Please note that single ended phono or balanced XLR connections are available however they must not be used simultaneously The LFE input to the subwoofer is not be affe...

Page 10: ...d are not applicable to the LFE input where it is assumed an external surround sound processor is controlling the bass management externally L R EQ Selects the Equalisation EQ that is applied to the LEFT and RIGHT line level inputs There are 7 different EQs as defined on page 22 The subwoofer will default to the standard flat EQ unless an alternative is selected LFE EQ Selects the EQ that is appli...

Page 11: ...to switching the amplifier ON L R L R L R L R Stereo line level connections Stereo speaker level connections L R C SUB LS RS L R C SUB LS RS LFE line level connections For use with bass limited small main loudspeakers LFE line level connections For use with full range large main loudspeakers K7262 REF 209208 Combined Manual_v2 12 2 08 12 40 Page 18 ...

Page 12: ...level input is specifically for the LFE Low Frequency Effects output from a surround sound A V processor Please note that single ended phono or balanced XLR connections are available however they must not be used simultaneously The LFE input to the subwoofer will not be affected by the frequency or slope settings which apply only to the Left and Right channel line inputs Once your subwoofer is con...

Page 13: ...position Please note that you can press SETUP at any point to abort the room correction process and stop the sweep sounding Connect the supplied KEF microphone with the supplied XLR lead to the rear of the subwoofer Press room correction SETUP on the remote control Remove the grille and place the microphone 2 inch 50mm away from the subwoofer driver Press SELECT and wait whilst a sweep is sounded ...

Page 14: ...e suction vacuum cleaner with soft brush attachment Your Reference Series Model 209 subwoofer is guaranteed against manufacturing defects in both materials and workmanship For further details of how this guarantee affects you please read the enclosed Warranty leaflet It should be noted however that failure of the loudspeaker due to abuse improper or inappropriate use and or operation or damage cau...

Page 15: ...W Class D amplifier has been custom designed to form a seamless partnership Utilising a switched mode power supply top end performance can be delivered in a highly efficient unit without compromising cabinet design The acoustically inert cabinet is beautifully hand finished with a level of craftsmanship and attention to detail that complements the precision of the components it contains The Bass r...

Page 16: ...ou should notify your retailer or consultant immediately Retain the packaging in case a need arises for you to transport the subwoofer at a later date You will notice that a special KEF care pack is included with the subwoofer This pack contains all the required accessories for connecting and positioning your loudspeakers The care pack Accessories Each Reference Series 208 subwoofer is supplied wi...

Page 17: ... rock at all Subwoofer Positioning The listening room is one of the most variable elements in the hi fi chain and its effect cannot be emphasised too strongly nor can its effects be reliably predicted As the sub bass low frequency sound produced by the subwoofer is close to omni directional positioning of the subwoofer is less critical than with full range conventional speakers However it is advis...

Page 18: ...ly for an LFE Low Frequency Effects output from a surround sound processor Please note that single ended phono or balanced XLR connections are available however they must not be used simultaneously The LFE input to the subwoofer is not affected by the frequency or slope controls and it will not therefore conflict with the bass management settings applied by the external surround sound processor Gr...

Page 19: ...ases the internal low pass filter cut off frequency in the subwoofer between 40Hz and 140Hz so that it integrates smoothly with the main speakers It is only applied to the Left and Right inputs and is not applicable to the LFE input where it is assumed an external surround sound processor is controlling the bass management externally Subwoofer Satellite Integration Correct Subwoofer Satellite Inte...

Page 20: ...to switching the amplifier ON L R L R L R L R Stereo line level connections Stereo speaker level connections L R C SUB LS RS L R C SUB LS RS LFE line level connections For use with bass limited small main loudspeakers LFE line level connections For use with full range large main loudspeakers K7262 REF 209208 Combined Manual_v2 12 2 08 12 40 Page 36 ...

Page 21: ...the controls whilst listening to a varied selection of music until you are satisfied with the sound balance Combined movie and music setup The Reference Series 208 subwoofer can be used for both main speaker low frequency extension and the LFE channel reproduction for a surround sound system Set the subwoofer up as described in section Music Only Setup With the subwoofer correctly set up for stere...

Page 22: ...the loudspeakers and therefore when faults occur careful and analytical diagnosis will be required to locate the actual source of trouble Faults in a loudspeaker will be audible on all programme sources A fault which is evident only when playing CDs but not for example when using a radio tuner is unlikely to originate with the loudspeakers Service problems should be discussed in the first instance...

Page 23: ...using it as the surround to the loudspeaker diaphragm while using new materials for the diaphragm itself Cooke was always looking for new materials and settled on Bextrene as a solution as its lightweight plastic sheet like properties were flexible enough for shaping and the material remained stable under varying temperature and moisture conditions and was smooth and consistent over a wide bandwid...

Page 24: ...with KEF s coupled cavity bass loading a system which positions the drivers internal to the enclosure each separately loaded and firing into a third common chamber which delivers very tight and accurate bass to the listening area via a substantial front mounted port This combines the taut sonic character of a sealed box with the higher sensitivity of a reflex design and succeeds in providing a hug...

Page 25: ...wledge that all of his original and noble principles remained intact and would always do so Recognition that year for the Reference Series Model Four had reached a peak with world wide acclaim Reviews by internationally famed and respected writers were quick to praise the merits of the company s new flagship model with its fourth generation Uni Q driver and to point out the sheer engineering excel...

Page 26: ...ion the presence of the granules makes each enclosure sound twice as big as it actually is Yet more KEF innovations soon followed The KIT KEF Instant Theatre concept for example proved an immediate hit an integrated multimedia home entertainment system for consumers who want a complete user friendly package that offers quality sound without being complicated to set up One of the most revolutionary...

Page 27: ...K7262 REF 209208 Combined Manual_v2 12 2 08 12 41 Page 50 ...

Page 28: ......

Page 29: ... Heinrichstraße 51 D 44536 Lünen Deutschland Tel 49 0 231 9860 320 Fax 49 0 231 9860 330 GP Acoustics France SAS 39 Rue des Granges Galand BP414 37554 Saint Avertin CEDEX France Tel 33 0 2 47 80 49 01 Fax 33 0 2 47 27 89 64 GP Acoustics HK Limited 6F Gold Peak Building 30 Kwai Wing road Kwai Chung N T Hong Kong Tel 852 2410 8188 Fax 852 2401 0754 KEF JAPAN 1 11 17 Honcho Koganei City Tokyo JAPAN 1...

Reviews: