background image

XL - pro

Error indication

Maintenance

The charger can be cleaned with a moister cloth. Running water and deter

-

gent contained  solvent may not be used.

Repair of the chargers may only be done by an authorised shop and that 

included replacement of the battery cables.

The charger is excessive overloaded 

in the supply mode

The charger is overloaded in the 

supply mode

The charger has lost the mains supply 

during charging

The charger needs service because it 

have failed during the self testing

No battery is connected

The clamps are shorted

A battery with a voltage over 32V have 

been connected

There can be two reasons for no indication in the battery tester during 

testing:

• 

The battery in the car is deep discharged.

• 

Wrong polarization of the clamps on the battery.

Summary of Contents for XL - pro

Page 1: ...XL pro Keepower Battery Charger User guide...

Page 2: ...light Flash light button Mains cable Plus clip Red Minus clip black Display Navigation buttons Selection button Enter and power on off USB charging connection Battery temperature sensor The Keepower...

Page 3: ...thorised shop The charger is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge un less they have been given su...

Page 4: ...s a device hanging on an edge Navigation in the menu There are 4 buttons for navigation in the menu Arrow Up is used for moving the cursor up in the menu Arrow Down is used for moving the cursor down...

Page 5: ...ted to Mains The menu language selection is activated by pressing the back button scrolling to the language to be used and select ing the language by pressing the Select button Activate language selec...

Page 6: ...it must have been resting for at least 4 hours no charging has taken place either in the vehicle or using the keepower Intelligent Battery Care charger If charging has taken place within the last 4 ho...

Page 7: ...el ligent Boost mode can be used Otherwise softcharge is activated automatically when charging starts recommended Deep Discharged If battery symbol is flashing Immediate charg ing is needed Charging w...

Page 8: ...rent Boost mode is used when trying to repair deep discharged batteries and is further described under The intelligent charging curve In the display the current voltage on the battery is showed togeth...

Page 9: ...le menu tree Battery not connected Select language Dansk English Deutsch Battery connected Charge Select voltage 12V 24V Select Ah 3 to 200 Select Battery type WET GEL AGM Boost Select voltage 12V 24V...

Page 10: ...battery has not been used for a longer period Bulk charging Indication on screen The Bulk charging phase is the phase where the battery under a constant current is charged up to app 85 of the full cap...

Page 11: ...en The Boost phase is used to kick start the battery if it has low power This Boost is made as an intelligent boosting This means that the charger is boosting the battery for hour with maximum current...

Page 12: ...essive overloaded in the supply mode The charger is overloaded in the supply mode The charger has lost the mains supply during charging The charger needs service because it have failed during the self...

Page 13: ...To obtain guarantee within the guaran tee period it is an absolute must that either a valid receipt or guarantee card is submitted to service station together with the appliance 1 2 Temperature senso...

Page 14: ...XL pro...

Page 15: ...XL pro...

Page 16: ...r MICRO Nom inal battery voltage 12V Charge current 0 8 A Fully charged Charging CLASSIC MICRO SMALL MEDIUM LARGE XL con XL pro 6V 12V 12V 12V 12V 12 24V 12 24V 0 8A 0 8A 4A 8A 15A 30A 15A 30A 15A 1 2...

Reviews: