12. Install elements no. 7B, 8B and 9B in mortar.
Secure the connection sleeve with insulation in the
hole on the front. Let the connection sleeve protrude
an equal distance to the thickness of the rendering
(approx. 10 mm)
Test fit the hot air grilles.
NOTE! The grilles must
not be cemented into place, they should be
loose. Otherwise, there is a risk that cracks may
form
The cleaning cover and the hot air grilles are perma
-
nently installed after the stove has been rendered
and painted.
K20 Top connection cont.
13. Assemble elements 7 and 8 in mortar.
Secure the
connection sleeve with insulation in the hole on the
front. Let the connection sleeve protrude an equal
distance to the thickness of the rendering (approx. 10
mm)
Test fit the hot air grilles.
NOTE! The grilles must
not be cemented into place, they should be
loose. Otherwise, there is a risk that cracks may
form
The cleaning cover and the hot air grilles are perma
-
nently installed after the stove has been rendered
and painted.
14. Install the 500 mm long pipe. Then, assemble
element no. 9 in mortar. Make sure that the insulation
is completely sealed between the pipe and element
9. The pipe must protrude approx. 50 mm above ele
-
ment no 9.
15. Install the hearth plates in the number order
shown in the illustration. Finish by installing the log
guard.
The stove is now ready for rendering. In connection with rendering, all grilles, cleaning covers and
frames for wall installation must be fitted to prevent the dried rendering mortar from obstructing the
final assembly. TIP! In connection with fitting, it is best to carefully press in grates, cleaning covers and
frames for wall installation a few millimetres into the wet mortar. In this way, these parts are slightly re
-
cessed into the rendering when the stove has dried and you finally install these parts.
Once the rendering is completed, the stove must dry for a week. After this time, you can fire with care on
three to four evenings (two to three fires per evening). After this, you can paint the stove. Suitable paints
are water based wall paints.
- 9 -
Insulation
Sleeve protru-