KeCheng KC-098 Operation Manual Download Page 5

 

5

 

wn. 

ith the corrosive gas or other corrosive materials. 

 to vibration and high or low temperature environment. 

ot in use for an extended period of time in case of damage of tool 

by deterioration of battery. 

Cautions 

z

 

Operate with care and do not let the tool drop do

z

 

Do not disassemble the tool in case of damage. 

z

 

Do not place the tool w

z

 

Avoid rain and water. 

z

 

Do not exposed the the tool

z

 

Storage the tool indoor. 

z

 

Do not put the tool in the water ,avoid to damage the tool. 

z

 

Remove the battery when n

 

 

TECHNICAL SPECIFICATIONS 

t Stud Scanner 

 
Name   

Intelligen

Type  

KC-098 

Object of detection 

Joists, AC live wires and Metals 

Joists 

Thickness of wall is 19mm(3/4 inches). 

AC live wires 

50mm(2 inches) deep away from the wall 

Detection 
capability 

Metals 

ep away from the wall 

38mm(1 1/2 inches )de

Power supply 

A 9 volt block battery 

Operation current 

<50mA 

Operation temperature 

 

+5

+40

Operation humidity 

30%

70% 

Storage environment 

ttery not included

 

-20

+60

,

85%

ba

Dimensions 165mm×80mm×30mm 
Weight About 

150g

battery not included

 

z

 

Tips 

y

 

Thank you for purchasing our products. 

y

 

We hope you to understand that the tool is not a all-purpose tool that can detect all the 

ore operation. 

 

Keep the tool appropriately after use. 

materials in the wall. 

y

 

Please read the instruction manual bef

y

 

WARRANTY

 

y quality problem or non-artificial damage, 

 conditions: 

ng from, but not limited to wear, water, being dropped or repairs 

, please 

ccording to local laws and regulations to deal with it, instead of throw it into the dustbin. 

 

      Within one year from the date of purchase, if an
provide warranty service by the relevant documents.

 

  Notice: The warranty does not apply to the following

• 

Disassembling the laser tool will void the warranty. 

• 

Any damage resulti

attempted by others. 

Tips

 :Most part of the product can be recycled, if you need to deal with this product

a

Summary of Contents for KC-098

Page 1: ...Intelligent Stud Scanner Model KC 098 Operation Manual 1 ...

Page 2: ... of joists or metals Battery safe prompting Please remove the battery when clean the product Remove the battery when not in use for an extended period of time Please install the batteries properly as the instructions of the positive and negative charges Please dispose the batteries properly High temperature will cause explosions and do not burn the batteries Strap insulated tape around the battery...

Page 3: ...ng to the the caution light for live wires will flash after to the ideal induction degree and process as per the slowly and hold the tool firmly sides go out ng another place 2 When approaching or detec live wires will flash after calibration B Detecting calibration for AC live wires Set the mode switcher to the mode for AC live w the meth ice When calibrating the tool will automatically set the d...

Page 4: ... a According to the cali the ideal induction b Operate the tool and find out the two edges of metal studs and make a mark with referenc walls c TIPS ON OPERATION z tion please replace the battery when abnormal calibration or e scanner z operation and keep the other hand at least 6 inches away from the tool during detection er of the target object but the width of the target t place ct the slate or...

Page 5: ... block battery Operation current 50mA Operation temperature 5 40 Operation humidity 30 70 Storage environment ttery not included 20 60 85 ba Dimensions 165mm 80mm 30mm Weight About 150g battery not included z Tips y Thank you for purchasing our products y We hope you to understand that the tool is not a all purpose tool that can detect all the ore operation Keep the tool appropriately after use ma...

Reviews: