![Keba KeContact R10 CM Installation Manual Download Page 19](http://html2.mh-extra.com/html/keba/kecontact-r10-cm/kecontact-r10-cm_installation-manual_5095484019.webp)
KeContact R10 CM
15
Installation Manual V 1.01
(translated)
7.3
Resettable thermostat
In according to EN 61316 the KeContact R10 is provided by a thermal cut-out, in case
of overheating this disconnect the line during the charge. If it happens switch off the
current and press the red button to reset to the normal operation.
7.4
Termal fuse.
A non-resettable termal fuse is soldered on the mainboard, it only intervenes in cases
of severe overheating and can be replaced only by authorized personnel.
Operation and handling