![Keba KeContact R10 CM Installation Manual Download Page 14](http://html2.mh-extra.com/html/keba/kecontact-r10-cm/kecontact-r10-cm_installation-manual_5095484014.webp)
KeContact R10 CM
10
Installation Manual V 1.01
(translated)
5.3
Mounting of cable reel
For a correct installation of the KeContact R10 need n°4 x anchor bolt with washer are
recommended. Print the last 2 pages of this document for drilling templates
The KeContact R10 should only be mounted vertically with the cable output facing down.
Mounting and installation instructions
90 mm
61 mm
Recommend installation at a height of 170 cm above the ground or between
90 cm and 110 cm for wheelchair users.
900 ÷ 1100mm
1700 mm