Motor connec-
tion
Synchronous motors from LTi are optimally tuned for the positioning con-
troller CDF3000. Prefabricated motor and encoder cables are also availa-
ble. For further information on motors of series LSH and accessories
please refer to the "Ordering Catalogue for Servo Motors, ID.-No.
0814.05B.x-xx“.
Attention:
Motor phases U,V and W must under no circumstances be
mixed up by mistake! With motor phases reversed the posi-
tioning controller has no control over the motor. The motor
may jerk or accelerate in an uncontrolled manner ("race up").
Attention:
At the motor terminals the device is not earth-fault proof !
Step
Action
Comment
1
Look for the desired synchronous motor.
There are three motors available
(LST-037, LSH-050, LSH074).
2
Wire the
motor phases
U, V, W via a
shielded cable and earth the motor to X3/
PE.
Use the prefabricated motor
cable for
type KM2-KSxxx
3
The connection of the temperature
sensor PTC or KTY is also routed through
the encoder cable (see chapter 3.x.
Use the prefabricated encoder
cables:
KRY2-CDF-KSxxx
(Resolver)
Fig. 3.5
Connection of motor
X3
W
V
U
PE
Info:
The CDF3000
positioning controllers
are at the terminals
during operation short-
circuit proof. In the
event of a short-circuit
or earth fault in the
motor cable, the output
stage is disabled and
an error message is
submitted.
X3
U
V
W
PE
M
3~
V
U
W
KM2-KSxxx
Summary of Contents for CDF3000
Page 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Page 12: ...Operating Instructions CDF3000...
Page 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Page 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Page 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Page 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...