background image

C O M B I V E R T

00.F5.SEM-KA01

11/2004

Installation Guideline

C

GB

A-Housing

Summary of Contents for COMBIVERT F5 Servo

Page 1: ...C O M B I V E R T 00 F5 SEM KA01 11 2004 Installation Guideline C GB A Housing...

Page 2: ...instruction manuals and documents giving assistance for the construction documentation and service is provided at the end of this manual The safety and warning notes listed in this instruction manual...

Page 3: ...nection 12 3 4 1 Resolver connection at KEB motors with connector X3A 12 3 4 2 Incremental encoder input emulation X3B 13 3 5 Control board 14 3 5 1 Control terminal strip X2A 14 3 5 2 Connection of t...

Page 4: ...n and cooling of the appliances shall be in accordance with the specifications in the pertinent documentation The drive converters shall be protected against excessive strains In particular no compone...

Page 5: ...ied by KEB Servo controllers are components which are intended for the installation in electric systems or maschines 2 2 Unit identification Motor cooling 0 Self cooling 1 External cooling Interface t...

Page 6: ...5 20 28 Ohm 82 60 150 110 Ohm 82 82 330 160 A 5 5 7 5 5 7 5 A 2 3 4 1 6 4 1 V 180 260 0 305 500 0 Hz 50 60 2 V 3 x 0 UN Hz 0 400 m 10 10 m 40 50 20 50 0 s 20 s 40 s 60 s 80 s 100 s 120 s 100 150 200 2...

Page 7: ...n for braking resistor T1 T2 Connection for temperature sensor switch L1 N L2 L3 1 3 phase mains connection 230V class L1 L2 L3 3 phase mains connection 400V class DC voltage supply in output for DC s...

Page 8: ...cooling measures by the machine builder This can be in the best case no further measure at all e g at cyclic operation with down times up to the dissipation of the entire indicated heat loss at rated...

Page 9: ...l Strip X1 A P E L 1 N L 2 L 3 P E L 1 L 2 L 3 Terminalstrip X1 A 230 V class 230 V AC 1 phase L1 N 230 V AC 3 phase L1 L2 L3 DC Supply 250 370 V DC Terminalstrip X1 A 400 V class 400 V AC 3 phase L1...

Page 10: ...n 230 V class 250 370 V DC 2 x 1 5 mm DC connection 400 V class 2 x 1 5 mm 420 720V DC 3 3 3 Mains connection 3 3 4 Motor connection terminal strip X1 B T 2 T 1 P B P A W V U P E PE Connection for ear...

Page 11: ...y unit with own voltage supply optionally Apply shieldings over a large contact surface of the mounting plate gr ye 1 2 3 7 8 5 6 Motor connector 3 3 5 Connection of the temperature monitoring T1 K1 1...

Page 12: ...ine length 50 m PB N X1A T1 T2 L PA PA PB OH1 OH2 U K1 11 12 X1B PE N L PE 3 3 6 Connection of a braking resistor with temperature monitoring in accordance with UL PA PB Connection for braking resisto...

Page 13: ...ency 300 kHz Signals RS 422 2 track signals and zero signals max transmission link 50 m Approved encoder types K bler RS 422 signals with 10 30V voltage supply The 12 V supply voltage at X3B is loadab...

Page 14: ...Vss Through the separate supply the control can also be operated at switched off driver power section Reference potential for digital inputs outputs Programmable relay output Load capacity max 30 VDC...

Page 15: ...educed to 30 k To avoid interferences a separate shielding must be provided for analog and digital control lines Depending on the use of the relay outputs an extra shielding is to be used too In case...

Page 16: ...g the inverter it is always started with the last stored values or the factory setting 4 1 3 Interface operator part number 00 F5 060 2000 The interface operator corresponds to the functional range of...

Page 17: ...ation 4 2 1 Parameter numbers and values When switching on KEB COMBIVERT F5 the value of parameter CP 1 appears Principally during a change parameter values are immediately accepted and stored non vol...

Page 18: ...lowing modes are possible The menu admissible for the application is defined by the machine builder The password input is generally made over the parameter CP 0 The adjusted password menu is maintaine...

Page 19: ...f zero speed CP 1 9 Load mot dependent para CP 20 Absolute position enc 1 CP 21 Encoder 1rotation CP 22 max reference forward CP 23 Step value 1 CP 24 Step value 2 CP 25 acc time forward CP 26 dec ti...

Page 20: ...ust the controller to a not aligned motor If the ystem position of the motor is unknown an automatic trimming can be done Before starting with the adjustment the direction of rotation must be checked...

Page 21: ...pre warning 8 Overtemperature alert signal power stage 9 External overtemperature pre warning motor 1 1 Overtemperature pre warning OHI 20 Actual value set value CP 3 Fcon rcon not at noP LS error SSF...

Page 22: ...ching speed 0 2 A PRx Quick stop holding torque at speed 0 3 A PRx Immediate disabling of modulation 4 A PRx Quick stopping disabling of modulation after reaching speed 0 5 A PRx Quick stop holding to...

Page 23: ...r may need to take corresponding measures 6 2 Manufacturer s Declaration A manufacturer declaration in accordance with 89 392 EEC can be provided by KEB if needed 6 3 UL CUL Marking 6 Certifications T...

Page 24: ...ructions Part 2 Power Circuit Part 3 Control Circuit Service notes Up Download of parameter lists with KEB COMBIVERT Error messages Instruction and information for construction and development Applica...

Page 25: ...25...

Page 26: ...26...

Page 27: ......

Page 28: ...33 1 45767495 net www keb fr mail info keb fr KEB UK Ltd 6 Chieftain Buisiness Park Morris Close Park Farm Wellingborough GB Northants NN8 6 XF fon 44 1933 402220 fax 44 1933 400724 net www keb uk co...

Reviews: