11
PE
U
V
W
PA
PB
T1
T2
X1.B
Connector
Cable
PIN No.
Name
Core No.
1
U
1
4
V
2
3
W
3
2
PE
green-yellow
A
Brake +
5
B
Brake –
6
C
PTC contact
7
D
PTC contact
8
Installation and Connection
• Plug in all connectors only in off-circuit condition !
• Observe correct phase sequence of the motor!
• Shielded motor line
PTC-Connector*
)
PTC-Connector*
)
Brake +
Brake –
Motor
Power connector
A
B
C
D
1
2
3
4
PE
U
V
W
ext. brake supply unit
with own voltage supply
(optionally)
Apply shieldings over a large
contact surface of the mounting
plate
gr/ye
1
2
3
7
8
5
6
Motor connector
3.3.5 Connection of the temperature monitoring
T1
K1
12
11
T2
Motor-PTC
Other
•
Terminals T1, T2
•
Tripping resistance 1.65...4 kOhm
•
Reset resistance 0.75...1.65 kOhm
•
Design in accordance with VDE 0660 Part 302
•
This function can be activated by the machine builder by software
•
Do not lay connecting cable together with control cable
•
Permissible in the motor cable only with double shielding
•
Connect relay K1 for fire prevention in regenerative operation (see 3.3.6)