19
DEvIcE DATA cOMbISTOP 28
3.2 Device data cOMbISTOP 28
3.2.1 Overview
Unit size
02
03
04
05
06
07
08
09
Rated torque after run in
M
2N
/ Nm
5
10
20
36
70
100
150
250
Rated power
P
20
/ W
25
30
30
48
62
65
75
80
Rated voltage
U
N_dc
/ V
24 / 105 / 180 / 205
5)
Cyclic duration factor
ED
/ %
100
Speed for service braking
rpm
3000 3000 3000 3000 3000 3000 3000 1500
Max. speed for emergency braking
rpm
6000 6000 6000 5000 5000 4500 3500 3000
Mass moment of inertia
J
/ 10
-3
kgm² 0,025 0,072 0,136 0,35 0,56 1,57 5,92 7,38
Air gap
X
N
/ mm
0,4
0,5
0,6
0,6
1
1
1,2
1,2
Switching cycles for half-wave rectifiers
1)
SC1
/ rpm
60
40
40
25
5
5
5
2
Switching cycles for bridge rectifier
1)
SC2
/ rpm
120
75
75
50
10
10
10
5
Switching cycles with powerbox DC
SC3
/ rpm
55
40
40
25
5
5
5
2
Separation time
2)
t
2
/ ms
40
60
100
120
240
240
300
350
Separation time with powerbox
2)
t
2
/ ms
20
35
50
60
120
120
150
170
Response delay AC
3)
t
11_ac
/ ms
40
80
140
180
200
400
700
900
Response delay DC
3)
t
11_dc
/ ms
10
15
20
25
25
50
60
60
Connection time AC
4)
t
1_ac
/ ms
90
140
200
240
330
650
900
1200
Connection time DC
4)
t
1_dc
/ ms
20
30
50
55
90
150
180
220
Feather key
according to DIN 6885/1
Keyway
according to DIN 6885/1
ISO class
B (optional F and H)
Table 5:
Device data COMBISTOP Type 28
1) Maximum permissible switching cycles when switching DC-side, continuous operation (100% ED) and max. operating temperature of 80°C.
2) Disengagement time from power-on to the beginning of the torque drop.
3) Delay time from switching off the current to the increase of the torque.
4) Connection time from switching off the current until reaching 0.9 x rated torque M
2N
.
5) 105/180/205 V are subject to the Low-Voltage Directive,
Summary of Contents for COMBISTOP 28
Page 2: ......