19
DEVIcE DATA
3.2.2 Electrical data of the motor chokes
Material
number
current
in A
Inductance
in mH
1)
Resistance
in m
Ω
1)
Frequency
in Hz
Typically
power loss
Frequency
range
in Hz
at 600Hz
in W
at 800Hz
in W
at 1600Hz
in W
07Z2F04-1003
2.6
3.5
407
800
—
18
26.5
0...1600
09Z2F04-1003
4.1
2.2
198
800
32
44
10Z2F04-1003
5.8
1.5
172
800
48
74
12Z2F04-1003
9.5
0.967
104
800
99
136
13Z2F04-1003
12
0.766
52
800
35
46
14Z2F04-1003 16.5
0.557
31
800
44
61
15Z2F04-1003
24
0.383
22
800
66
92
16Z2F04-1003
33
0.278
16
800
102
135
17Z2F04-1003
42
0.219
9.52
800
115
148
18Z2F04-1003
50
0.184
6
800
92
109
19Z2F04-1003
60
0.153
6
800
124
152
20Z2F04-1003
75
0.123
6.1
800
152
180
21Z2F04-1003
90
0.102
3.6
800
147
177
22Z2F04-1003
115
0.08
3.7
800
224
264
23Z2F04-1003
150
0,082
2.4
600
264
—
340
24Z2F04-1003
180
0.068
2.4
600
390
530
25Z2F04-1003
210
0,058
1.5
600
430
572
26Z2F04-1003
250
0.049
1
600
492
732
27Z2F04-1003
300
0.041
1
600
515
852
28Z2F04-1003
370
0.033
0.58
600
515
935
29Z2F04-1003
460
0.027
0.48
600
777
1079
30Z2F04-1003
570
0.021
0.39
600
963
1122
Table 6:
Electrical data of the motor chokes
1)
Limit deviation ±10%.
• Rated voltage corresponds to U
N
= 400 / 480V.
• All data are rated values except minimum and maximum values.
• The output frequency is to be limited in such a way that it does not exceed 1/10 of the switching
frequency.