29
3.6.1
Degrees of protection
The degrees of protection of the system are guaranteed only if the following condi-
tions are satisfied:
Material thickness at the mounting cut-out for IP66 protection: 2 mm to 4 mm.
Deviations of the plane of the mounting cut-out limits: ≤ 0.5 mm.
This condition must also be met with installed C6 HMI / C6 HMI LC.
Allowed surface roughness in the area of the seal: ≤ 120 microns (Rz 120).
3.6.2
Dimensions of the cut-outs
LCD
TFT
A
B
C
D
E
F
G
H
I
K
L
M
N
weight
(kg)
4.3”
140
95
5 30
-
5
-
84
-
-
128 131
86
0.7
5.7”
175 145 5 40
-
7
- 131
-
-
161 164 134
0.9
7.0”W
215 155 5 40
-
7
- 141
-
-
201 204 144
1.2
8.4”
255 190 5 19.5 29 7.5 15 130 30
42
156 243 179
1.4
10.1”W 293 201,5 5 19.5 29 6.5 15 130 43.5
62
156 285 193.5
1.6
10.4”
295 230 5 19.5 29 7.5 15 130 70
62
156 283 219
1.8
12.1”
325 260 5 19.5 29 7.5 15 130 100
77
156 313 249
2.1
12.1”W 321 222.5 5 19.5 29 6.3 15 130 65
76
156 313 215
2.0
15.0”
390 305 6 19.5 29 7.5 15 130 145 109.5 156 378 294
3.3
15.6”W 420 265 6 19.5 29 7.5 15 130 105 124.5 156 410 255
3.3
Summary of Contents for COMBICONTROL C6 HMI
Page 1: ...Document Part Version 20125246 GBR 00 C6 HMI C6 HMI LC Instruction Manual COMBICONTROL...
Page 2: ...2...
Page 5: ...5 SECTION 1 1 Introductory Information...
Page 10: ...10 SECTION 2 2 Description...
Page 16: ...16 Figure 7 C6 HMI C6 HMI LC 8 4 rear view Aeration holes Mounting seal 1 2 1 2...
Page 25: ...25 SECTION 3 3 Installation and connection...
Page 42: ...42...
Page 43: ...43 SECTION 4 4 Commissioning the device...
Page 47: ...47...
Page 48: ...48 SECTION 5 5 Commissioning a project...
Page 67: ...67 SECTION 6 6 Maintenance...