background image

32

 SySTEM  DESCRIPTION

2.11.3  Pentaband outdoor antenna

3 m cable

Wall mounting with 90° bracket

IP 67

50 W

2.5dBi

50 Ohm

248 mm

SMA-M

Figure 19:  C6 Router Pentaband stilo antenna features

Figure 20:  C6 Router Pentaband wall mounting antenna

Summary of Contents for C6

Page 1: ...ROUTER INSTRUCTION FOR USE C6 ROUTER Original Manual Document 20090747 EN 02...

Page 2: ......

Page 3: ...case of non observance of this safety instruction WARNING Dangerous situation which may cause death or serious injury in case of non observance of this safety instruction CAUTION Dangerous situation w...

Page 4: ...well as any user specific advice in spoken and written and through tests are made to best of our knowledge and information about the intended use However they are regarded as being only informal and...

Page 5: ...n 16 1 6 Maintenance 16 1 8 Repair 17 1 7 Disposal 17 2 System Description 18 2 1 Special features 18 2 2 Router package 18 2 3 Front view C6 Router E1 E4 21 2 4 Front view C6 Router L1 L4 23 2 5 Clos...

Page 6: ...Switching on and testing the COMBIVIS connect Router device 44 3 11 Connecting the serial port 45 3 11 1 Connecting to MPI or PPI networks 45 3 12 Connecting the digital inputs and outputs I O 47 3 1...

Page 7: ...6 5 3 Panel antenna drawing dimensions 64 6 5 4 Wall mount antenna drawing dimensions 65 6 5 5 Outdoor panel antenna drawing dimensions 66 6 6 Ports PINOUT 66 6 6 1 COM1 DB15M serial 66 6 6 2 Digital...

Page 8: ...Figure 21 Wall mounting procedure 34 Figure 22 Wall mounting procedure DIN rail mounting 34 Figure 23 Wall mounting procedure DIN rail mounting 35 Figure 24 Wall mounting procedure DIN rail mounting 3...

Page 9: ...t 53 Figure 48 Backup battery replacement 53 Figure 49 Backup battery replacement 54 Figure 50 Backup battery replacement 54 Figure 51 Backup battery replacement 55 Figure 52 Backup battery replacemen...

Page 10: ...stics 58 Table 4 Mechanical characteristics 58 Table 5 Environmental characteristics 58 Table 6 Panel antenna characteristics 59 Table 7 Panel antenna characteristics 59 Table 8 Wall mount Panel anten...

Page 11: ...ional Safety over Ethernet GND Reference potential ground Head mo dule Description for the bus coupler or small control in the KEB I O EtherCat system HMI Human machine interface touch screen IEC Inte...

Page 12: ...e systems Part 1 Princi ples requirements and tests IEC 60664 1 EN60721 3 1 Classification of environmental conditions Part 3 1 Classification of groups of environmental parameters and their severitie...

Page 13: ...8 1 7 Functional safety of electrical electronic programmable electronic safety related systems Part 1 7 VDE0803 1 7 IEC61508 1 7 EN61800 2 Adjustable speed electrical power drive systems Part 2 Gener...

Page 14: ...sulting claims against the manufacturer NOTICE Hazards and risks through ignorance Read the instructions for use Observe the safety and warning instructions If anything is unclear please contact KEB A...

Page 15: ...Mounting according to the specified degree of protection Make sure that no small parts fall into the device during assembly and wiring drilling chips screws etc This also applies to mechanical compone...

Page 16: ...g exists between the components to be connected e g by the equipotential line Disregard can cause destruction of the components by equalizing currents 1 5 Start up and operation When the device is ins...

Page 17: ...following table The corresponding KEB return addresses can be found on our website Withdrawal by WEEE Reg No Keyword Austria KEB Automation GmbH ERA 51976 Stichwort R cknahme WEEE France R CYLUM Recyc...

Page 18: ...e COM BIVIS connect Control Center online manual for further information ARM Cortex A8 processor 1 0 GHz 800MHz for ET version 512MB RAM DDR3 800 2 4GB eMMC memory file system organization for data st...

Page 19: ...ystem Description 2 2 Router package COMBIVIS connect Router device package consists of E L system DIN mount kit Wall mount kit n 1 Power supply plug n 1 Isolated IO plug Pentaband Stilo Antenna optio...

Page 20: ...20 System Description Pentaband Outdoor An tenna optional Pentaband Wall mount Antenna optional Antenna cable extension 3 5 m optional Figure 1 Router package...

Page 21: ...LED 4 COM 5 WAN ETH2 6 LAN ETH1 7 USB 8 COM Tx LED green 9 Remote connection LED green 10 Power LED green Figure 2 Front detail The following behaviors are defined Steady lighted Blinking Continuous...

Page 22: ...the initial registration Single 2 green blinks Configuration from USB stick successfully completed Single 2 red blinks User credential for Domain access not valid Single 3 green blinks COMBIVIS conne...

Page 23: ...7 USB 8 COM Tx LED green 9 3G 4G modem activity 10 3G 4G modem connection 11 RF antenna connector 12 Remote Connection LED green 13 Power LED green Figure 4 Front detail The following behaviors are d...

Page 24: ...than the first of the initial registration Single 2 green blinks Configuration from USB stick successfully completed Single 2 red blinks User credential for Domain access not valid Single 3 green bli...

Page 25: ...a strong signal from the network Blinking red SIM error e g wrong PIN 3G 4G MODEM activity Blinking green Modem currently connected Off Modem disconnected Figure 5 C6 Router L1 L4 front view 2 5 Clos...

Page 26: ...works as Connection mode also referred as selector key input By default the status of this input is ignored When the COMBIVIS connect Router device is configured to handle the input see General optio...

Page 27: ...ide C6 Router L1 L4 1 2 2 1 Full stainless steel enclosure 2 Aeration holes Figure 8 C6 Router L1 L4 right side 2 7 Left side C6 Router L1 L4 2 1 2 1 Full stainless steel enclosure 2 Aeration holes Fi...

Page 28: ...ok mounting plate holes 2 DIN book mounting hook holes 3 SIM card socket Figure 10 C6 Router L1 L4 rear side 2 9 Rear side C6 Router E1 ET E2 ET and E1 E4 1 1 1 1 2 2 1 Wall book mounting plate holes...

Page 29: ...2 10 Labels On the side panels there are the following labels 1 2 3 4 5 1 WAN MAC code 2 LAN MAC code 3 IMEI 4 Mat No 5 LAN IP 192 168 0 1 Mask 255 255 255 0 WAN IP DHCP User admin Password admin Figu...

Page 30: ...2 3 4 5 6 1 DC input 2 Digital input output 3 Electrical information 4 COM interface 5 Button for restoring factory settings 6 Reset button Figure 13 C6 Router labels 1 1 SIM card sticker Figure 14 C6...

Page 31: ...i 50 Ohm 48 mm SMA M Figure 15 C6 Router Pentaband stilo antenna features Figure 16 C6 Router Pentaband stilo antenna 2 11 2 Pentaband wall mounting antenna 3 m cable Wall mounting with 90 bracket IP...

Page 32: ...on 2 11 3 Pentaband outdoor antenna 3 m cable Wall mounting with 90 bracket IP 67 50 W 2 5dBi 50 Ohm 248 mm SMA M Figure 19 C6 Router Pentaband stilo antenna features Figure 20 C6 Router Pentaband wal...

Page 33: ...ng the shipment 3 3 Checking the operating conditions Read carefully the standards approvals EMC parameters and technical specifi cations for operation of the device This information is available in t...

Page 34: ...maxi mum permissible ambient temperature for operation Please contact KEB for details The device may otherwise be damaged and its certifications and warranty will be void 3 6 Preparing the mounting I...

Page 35: ...he instructions detailed in the figure There are 2 fastening points Fastening can be made using stainless steel screws M4x20 Figure 23 Wall mounting procedure DIN rail mounting Hang the system as show...

Page 36: ...36 Installation and Connection Step 3 Release the top to match the slots with the screws Step 4 Tighten the two screws Figure 24 Wall mounting procedure DIN rail mounting...

Page 37: ...n 3 7 2 Wall mounting procedure DIN rail mounting The system can be installed on a DIN guide as follows Mount the DIN hooks as shown Figure 25 Wall mounting procedure DIN rail mounting Mount the DIN m...

Page 38: ...ction Example of correct installation Figure 26 Wall mounting procedure DIN rail mounting To remove the system from the DIN guide Lift the system up and release it from the DIN mounting rail Figure 27...

Page 39: ...t be associated with a data traffic plan The traffic plan must be properly chosen depending on foreseen traffic generated by the remote assistance sessions and SMS notification usage for L1 L4 models...

Page 40: ...40 Installation and Connection Step 2 Pull the SIM card in the hole till you listen a click Figure 28 SIM installation...

Page 41: ...nstallation 3 9 1 Pentaband stilo antenna The exact dimensions for this are in the chapter Technical specifications dimension drawings Drill a 6 5 mm hole in the metal Recommended torque for mounting...

Page 42: ...nsion drawings Figure 30 Pentaband wall mounting antenna 3 9 3 Pentaband outdoor antenna The exact dimensions for this are in the chapter Technical specifications dimension drawings Drill a 13 0 mm ho...

Page 43: ...chieve this goal the following methods can be used Use an equipotential bonding cable 16mm2 suitable at least 75C to connect the equipment s ground to the COMBIVIS connect Router device s ground Conne...

Page 44: ...e as LAN automation network Figure 33 Connections for the Ethernet ports When using the cable connection for Internet it must be connected to the WAN port The LAN port shall be connected to the automa...

Page 45: ...l parts but user can adapt DB15 connec tor by himself For further details please contact KEB 3 11 1 Connecting to MPI or PPI networks The electrical specification of the MPI networks are often referri...

Page 46: ...stors mounted internally to the standard Profibus MPI connectors The KEB adapter cable provides on the DB9 F connection side all signals required by the MPI communication and the line connection The K...

Page 47: ...digital inputs and outputs I O with key switches buttons and lamps 3 12 1 IN0 WAN connection enabling security key Figure 38 IN0 WAN connection example for activating a security key 3 12 2 IN1 Reset...

Page 48: ...48 Installation and Connection 3 12 3 OUT0 WAN connection to activate signalling equipment Figure 40 OUT0 WAN to activate signalling equipment Figure 41 OUT0 WAN to activate signalling equipment...

Page 49: ...49 Installation and Connection 3 12 4 OUT0 Remote assistance service running Figure 42 OUT0 Remote services application Figure 43 OUT0 Remote services application...

Page 50: ...ng COMBIVIS connect Router device requires for the configuration COMBIVIS connect Control Center version 2 or above Control Center is available for download in the dedi cated product section of the ww...

Page 51: ...Figure 45 COMBIVIS connect Router E2 L2 models Select TCP in the upper left list Write the IP address of the Router WAN or LAN port IP Under Upload Device Path select the download path in which the pr...

Page 52: ...ls Please refer to the COMBIVIS connect Software User Manual for additional informa tion on retrieving data loggers of the E2 L2 router systems COMBIVIS connect E2 L2 models with integrated 2G 3G 3G m...

Page 53: ...battery backup when necessary NOTICE Notice Do not use detergents solvents cleaners or objects that could scratch the surface NOTICE Notice switch off the power before any cleaning operation 5 2 Back...

Page 54: ...54 Maintenance Remove the screw as indicated in the figure Figure 49 Backup battery replacement Locate the battery position Figure 50 Backup battery replacement Remove the battery...

Page 55: ...ls to backup and restore the contents of its internal memory in order to manage the configuration and the operating system of COMBIVIS connect Router device For more information please see the COMBIVI...

Page 56: ...f the USB Stick with the update and it will immediately start the system software update procedure A proper visual feedback will inform about the status of the operation No action is re quested by the...

Page 57: ...size sock et 512 MB DDR3 800 soldered Serial port Type 1 x RS232 422 485 DB15M software selectable Optoisolation Yes Ethernet interfaces Type 1 x 10 100Mbps WAN RJ45 with link activity leds 1 x 100Mbp...

Page 58: ...tion overvoltage solder fuse on the PCB These devices are intended to be connected to a Secondary Circuit Overvoltage Category II Table 3 Electrical characteristics Mechanical characteristics Housing...

Page 59: ...Bands GSM DCS PCS UMTS CDMA GPRS EDGE HSPA VSWR 2 3 Polarization Linear Power handling 20 W Impedance 50 Ohm Connector Straight SMA M Table 6 Panel antenna characteristics Environmental mechanical Tem...

Page 60: ...2 2 1 2 3 L angle bracket 1 7 1 8 2 2 1 7 1 9 Efficiency Free space 27 30 61 62 60 L angle bracket 69 66 59 68 65 Impedance 50 Polarization Linear Radiation pattern Omni directional Input power 50 W...

Page 61: ...Average gain 4 5 dB 2 5 dB 4 5 dB Efficiency 40 55 40 VSWR 3 0 1 Impedance 50 Polarization Linear Radiation properties Omni directional Input power 5 W Mechanical Dimensions mm Height 48 mm diameter 5...

Page 62: ...62 Technical Specifications 6 5 Dimension drawings 6 5 1 C6 Router E1 E4 Figure 53 Dimensions...

Page 63: ...63 Technical Specifications 6 5 2 C6 Router L1 L4 Figure 54 Dimensions...

Page 64: ...64 Technical Specifications 6 5 3 Panel antenna drawing dimensions Figure 55 Panel antenna drawing dimensions...

Page 65: ...65 Technical Specifications 6 5 4 Wall mount antenna drawing dimensions Figure 56 Wall mount antenna drawing dimensions...

Page 66: ...antenna drawing dimensions Figure 57 Outdoor panel antenna drawing dimensions 6 6 Ports PINOUT 6 6 1 COM1 DB15M serial PIN Signal I O 1 Isolated 5 VDC OUT 2 Transmit data RS 232 OUT 3 Receive data RS...

Page 67: ...ation RS 232 IN 13 Receive data RS 422 IN 14 Receive data RS 422 IN 15 N C Table 10 COM DB15M serial Any polarization or termination resistor connected to RS422 485 channel if required it has to be pr...

Page 68: ...on Number RED 2014 53 EU Text Directive on the availability on the market of Radio Equipment Number Hazardous Substances 2011 65 EEC incl 2015 863 EU Text Directive on the approximation of the laws of...

Page 69: ...UE radio and ancillary equipment 11 2016 ETSI EN 301 511 52 V9 0 2 Global System for Mobile communications Harmonized EN for mobile stations in GSM 900 and GSM1800 systems 03 2003 EMC EN 55024 Versio...

Page 70: ...of 2015 863 EU for restrictions of the use for certain hazardous substances in electrical and electronic equipment is given by qualification of components and manufacturing process within the ISO 900...

Page 71: ...71 Certification 7 2 UL Marking...

Page 72: ...72 NOTES...

Page 73: ...E KEB PARTNERS WORLDWIDE www keb co uk contact contact worldwide P R China KEB Power Transmission Technology Shanghai Co Ltd No 435 QianPu Road Chedun Town Songjiang District 201611 Shanghai P R China...

Page 74: ...Automation with Drive www keb de KEB Automation KG Suedstrasse 38 32683 Barntrup Tel 49 5263 401 0 E Mail info keb de...

Reviews: