background image

6

GAS HOT PLATE PARTS LIST

PART

ITEM

DESCRIPTION

MG-2

MG-4

NUMBER

1

GAS VALVE (INFINITE CONTROL)  WITH NG ORIFICE #49

CONSTANT PILOT

2

4

002666

SPARK IGNITOR

2

4

002666

ORIFICE, HOODED, NATURAL GAS, #49

2

4

002676

GAS VALVE (INFINITE CONTROL) WITH PROPANE ORIFICE #53

CONSTANT PILOT

2

4

002666

SPARK IGNITOR

2

4

002666

ORIFICE, HOODED, PROPANE, #53

2

4

032164

2

KNOB, RED, GAS VALVE

2

4

002667

3

CONSTANT PILOT VALVE

1

2

004266

4

CONSTANT PILOT ASSEMBLY WITH ORIFICE

1

2

004259

5

CONSTANT PILOT MOUNTING BRACKET

24" DEEP

1

2

------

30" DEEP

1

2

------

6

SPARK IGNITOR SWITCH

2

4

002666

7

SPARK IGNITOR MODULE

1

2

008934

8

SPARK ELECTRODE WITH WIRE

1

2

013899

9

SPARK ELECTRODE MOUNTING BRACKET

ABOVE ELECTRODE

1

2

------

BELOW ELECTRODE, 24" DEEP

1

2

------

BELOW ELECTRODE, 30" DEEP

1

2

------

10

WORK BOX, SPARK IGNITOR MODULE

1

2

------

11

BURNER

FRONT, 24" DEEP

1

2

006464

FRONT, 30" DEEP

1

2

002651

REAR, 24" DEEP

1

2

006465

REAR, 30" DEEP

1

2

006466

12

PRESSURE REGULATOR

NATURAL GAS

1

2

004236

PROPANE

1

2

023527

13

CORD WITH PLUG, 6', 16/3 SJO FOR SPARK IGNITOR

WITH WIRING HARNESS FOR MG-2

1

------

CORD WITH PLUG ONLY

1

1

006315

WIRE HARNESS ONLY

1

2

------

14

CONDUIT, 1/2" (SPECIFY FOR 24" OR 30" DEEP)

1

2

------

15

BUSHING, STRAIN RELIEF

1

2

000470

16

CONDUIT CONNECTOR, 1/2"

2

4

------

17

BURNER GRATE

2

4

002674

18

GRATE DIVIDER

MG-2, 24" DEEP

1

014601

MG-2, 30" DEEP

1

007895

MG-4, 24" DEEP

1

014602

MG-4, 30" DEEP

1

008933

19

CONTROL PANEL

MG-2

1

------

MG-4

1

------

20

DRIP PAN ASSEMBLY

MG-2 24/30, MG-4 24

1

2

018548

MG-4 30

1

2

019086

21

GRATE SEPARATOR, MG-4

2

002663

Summary of Contents for MG-2

Page 1: ...MG 2 MG 4 GAS HOT PLATE SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com Hot Plate 0107 09 07...

Page 2: ...ical Connection 3 Gas Leak Testing 3 4 SECTION III OPERATING Lighting 4 Shutdown 4 Cleaning 4 SECTION IV MAINTENANCE Warranty Repairs 4 Preventive Maintenance 4 SECTION V SERVICE DIAGNOSIS General 5 T...

Page 3: ...OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ T...

Page 4: ...s are designed to operate on the gas fuel specified on the serial plate and must not be operated with another gas fuel They cannot be converted to another gas fuel by turning or engaging a switch FOR...

Page 5: ...NNER SO THAT IT IS CLEARLY UNDERSTOOD BY THE EMPLOYEE AND THE EMPLOYEE SHOULD BE ASKED IF IN FACT HE OR SHE UNDERSTANDS THE CORRECT METHOD OF OPERATION OF THE EQUIPMENT AND THAT A RISK OF EXPOSURE EXI...

Page 6: ...nce Connect the hot plate to the main gas supply line at the rear of the hot plate The piping should be a minimum of 3 4 IPS supply pipe for a single hot plate A 3 4 NPT manual gas valve is shipped wi...

Page 7: ...the desired setting after the burner ignites NOTE The left knob operates the back burner and the right knob operates the front burner SHUTDOWN 1 Rotate the red knob fully clockwise for each burner CL...

Page 8: ...times If plates are damaged or lost replace them immediately 5 PROBLEM PROBABLE CAUSE SOLUTION Constant pilot won t light a Gas isn t turned on a Turn gas valve on If using flexible connector with qu...

Page 9: ...9 SPARK ELECTRODE MOUNTING BRACKET ABOVE ELECTRODE 1 2 BELOW ELECTRODE 24 DEEP 1 2 BELOW ELECTRODE 30 DEEP 1 2 10 WORK BOX SPARK IGNITOR MODULE 1 2 11 BURNER FRONT 24 DEEP 1 2 006464 FRONT 30 DEEP 1 2...

Page 10: ...7 HOT PLATE ASSEMBLY NOTE MG 4 hot plates are built as two MG 2 hot plates side by side The MG 2 is shown here NOTE Part numbers correspond with the Hot Plate Parts list on page 9...

Page 11: ...below apply to hot plates with spark ignition SI Hot plates with constant pilots CP do not have any electrical connections NOTE MG 4 hot plates are essentially two MG 2 hot plates side by side Each c...

Page 12: ...PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from...

Page 13: ...SERIAL NUMBER __________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS ________________________________ TOP SIDE COOKER HOT PLATE PASTA PLUS I HAVE READ THE INSTALLATION AND OPERATION INSTRUCTI...

Reviews: