background image

2

THIS HOT PLATE MAY NOT BE ALTERED,
MODIFIED OR CHANGED IN ANY WAY.

The State of California enacted the California Safe
drinking water and Toxic Enforcement Act of 1986,
(Prop.65), which “prohibits any person in the course of
doing business from knowingly and intentionally
exposing any individual to a chemical known to the
State of California to cause cancer or reproductive
toxicity without first giving clear and reasonable warning
to such individuals.” The Governor’s Scientific Advisory
Panel added carbon monoxide to the list of hazardous
chemicals known to cause reproductive harm.

In order to establish full compliance with Proposition 65,
we attached a yellow warning label to each gas fired hot
plate manufactured by Keating of Chicago, Inc.

Carbon monoxide would not be present in
concentrations that would pose a “significant risk” to the
consumer when the equipment is installed, operated
and maintained as follows:

Installed under a properly designed operating
exhausting good.

Connected to the type of gas for which the hot plate
is manufactured.

Pressure regulator is installed in the appliance and
adjusted for the manifold pressure marked on the
serial plate.

Adequate air supply to the appliance.

In-line pressure regulator, not supplied by Keating,
must be installed outside the appliance.

The equipment is operated in the manner intended
using the proper utensils.

Keep the equipment clean and have it checked
periodically.

Burner air adjustments, mechanical maintenance and
repairs must be performed by qualified service
personnel.

If the equipment is not installed, operated and
maintained in accordance with the above,
concentrations of carbon monoxide in excess of the
established limits could be present in the kitchen
environment.

ALL PERSONNEL IN THE WORK PLACE WHO MAY
BE SUBJECT TO ANY EXPOSURE OF CARBON
MONOXIDE MUST

BE WARNED OF SUCH

POSSIBLE EXPOSURE. THIS WARNING SHOULD BE
CONVEYED IN A MANNER SO THAT IT IS CLEARLY
UNDERSTOOD BY THE EMPLOYEE, AND THE
EMPLOYEE SHOULD BE ASKED IF IN FACT HE OR
SHE UNDERSTANDS THE CORRECT METHOD OF
OPERATION OF THE EQUIPMENT AND THAT A RISK
OF EXPOSURE EXISTS IF THE EQUIPMENT IS
OPERATED IMPROPERLY.

WARNING

IF NOT INSTALLED, OPERATED AND MAINTAINED
IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS, THIS PRODUCT COULD EXPOSE
YOU TO SUBSTANCES IN FUEL OR IN FUEL
COMBUSTION WHICH CAN CAUSE DEATH OR
SERIOUS ILLNESS AND WHICH ARE KNOWN TO
THE STATE OF CALIFORNIA TO CAUSE CANCER,
BIRTH DEFECTS OR OTHER REPRODUCTIVE
HARM.

II INSTALLATION

This hot plate MUST be installed, inspected, and
serviced by qualified and/or certified and/or licensed
service personnel – you may void your Keating warranty
if installation is not completed per current local, national
and Keating specifications. Contact your dealer for
assistance.

DAMAGE DURING SHIPMENT

The hot plate has been assembled, tested and
inspected at the factory. Upon arrival, the complete hot
plate should be checked for any damage that may have
occurred during shipment.

The carrier is responsible for all damage in transit
whether visible or concealed. Do not pay for the freight
bill until the hot plate has been thoroughly checked for
damage. If concealed damage is found later, contact the
carrier immediately to file a claim.

What to do if equipment arrives damaged:

VISIBLE LOSS OR DAMAGE – Be certain to note this
on the freight or express receipt and have it signed by
the delivery person.

FILE CLAIM FOR DAMAGES IMMEDIATELY –
Regardless of extent of damage.

CONCEALED LOSS OR DAMAGE – If damage is
noticed when equipment is unpacked, notify the freight
company immediately, and file a “concealed damage
claim”. This MUST be done immediately. Be sure to
retain the shipping container for inspection.

Keating does not assume responsibility for Loss OR
Damage incurred in transit.

INSTALLATION

Installation must conform with local codes or, in
absence of local codes, with current National Fuel 
Gas Code ANSI Z223.1/NFPA 54, Natural Gas
Installation Code CAN/CGA-B149.1 or Propane
Installation Code CAN/CGA-B149.2. When pressure

Summary of Contents for MG-2

Page 1: ...MG 2 MG 4 GAS HOT PLATE SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com Hot Plate 0107 09 07...

Page 2: ...ical Connection 3 Gas Leak Testing 3 4 SECTION III OPERATING Lighting 4 Shutdown 4 Cleaning 4 SECTION IV MAINTENANCE Warranty Repairs 4 Preventive Maintenance 4 SECTION V SERVICE DIAGNOSIS General 5 T...

Page 3: ...OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ T...

Page 4: ...s are designed to operate on the gas fuel specified on the serial plate and must not be operated with another gas fuel They cannot be converted to another gas fuel by turning or engaging a switch FOR...

Page 5: ...NNER SO THAT IT IS CLEARLY UNDERSTOOD BY THE EMPLOYEE AND THE EMPLOYEE SHOULD BE ASKED IF IN FACT HE OR SHE UNDERSTANDS THE CORRECT METHOD OF OPERATION OF THE EQUIPMENT AND THAT A RISK OF EXPOSURE EXI...

Page 6: ...nce Connect the hot plate to the main gas supply line at the rear of the hot plate The piping should be a minimum of 3 4 IPS supply pipe for a single hot plate A 3 4 NPT manual gas valve is shipped wi...

Page 7: ...the desired setting after the burner ignites NOTE The left knob operates the back burner and the right knob operates the front burner SHUTDOWN 1 Rotate the red knob fully clockwise for each burner CL...

Page 8: ...times If plates are damaged or lost replace them immediately 5 PROBLEM PROBABLE CAUSE SOLUTION Constant pilot won t light a Gas isn t turned on a Turn gas valve on If using flexible connector with qu...

Page 9: ...9 SPARK ELECTRODE MOUNTING BRACKET ABOVE ELECTRODE 1 2 BELOW ELECTRODE 24 DEEP 1 2 BELOW ELECTRODE 30 DEEP 1 2 10 WORK BOX SPARK IGNITOR MODULE 1 2 11 BURNER FRONT 24 DEEP 1 2 006464 FRONT 30 DEEP 1 2...

Page 10: ...7 HOT PLATE ASSEMBLY NOTE MG 4 hot plates are built as two MG 2 hot plates side by side The MG 2 is shown here NOTE Part numbers correspond with the Hot Plate Parts list on page 9...

Page 11: ...below apply to hot plates with spark ignition SI Hot plates with constant pilots CP do not have any electrical connections NOTE MG 4 hot plates are essentially two MG 2 hot plates side by side Each c...

Page 12: ...PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from...

Page 13: ...SERIAL NUMBER __________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS ________________________________ TOP SIDE COOKER HOT PLATE PASTA PLUS I HAVE READ THE INSTALLATION AND OPERATION INSTRUCTI...

Reviews: