8. Dissolve 2/3 cup of Keating Sea Powder for
every fi ve gallons of water and let soak for 1/2
hour. If there is a large build-up of carbonized
grease, allow fryer to soak overnight.
CAUTION:
When soaking overnight, make sure the
fryer is turned off.
CAUTION:
Do not damage or reposition thermostat
probe as this may affect the accuracy of the fryer.
9. While soaking, a natural fi ber brush may be used
to scrub the tubes and inside walls of fryer.
10. Drain the water and Sea Powder into a dry suit-
able receptacle and remove from cooking area.
NOTE:
DO NOT pump water through the fi lter
machine.
11. Spread Keating Klenzer liberally on tubes and
sides of fryer vessel.
12. A non-abrasive scouring pad may be used to
remove the now softened carbonized grease.
13. Thoroughly rinse fryer vessel with potable water
to remove all Klenzer.
14. Prior to refi lling with oil, wipe the inside of the
fryer vessel making sure all water and Klenzer has
been removed.
WATER IN ANY FORM AND HOT OIL DON'T MIX!
15. Close drain valve.
FAILURE TO CLOSE DRAIN VALVE BEFORE REFILL-
ING THE FRYER MAY RESULT IN SERIOUS INJURY.
WHEN YOUR FRYER IS BEING USED IN CONJUNC-
TION WITH A CENTRAL FILTER, DISCONNECT
POWER SUPPLY BEFORE RESETTING MOTOR TO
PREVENT SERIOUS INJURY WHEN RESET SWITCH
IS ENGAGED (SEE FILTER MANUAL).
16. Check thermostat bulb positioning -
see page 11.
17. Refi ll the fryer with new or fi ltered oil.
ELECTRONIC TIMERS
The electronic timers provide a clearly visible and ac-
curate display and are very easy to use. This proce-
dure resets the timer to operate in minutes:seconds.
A. Timer Operation
B. How to program the “Keating” Electronic Timer
STEP 1
Make certain power to the timer has been OFF for
at least 30 seconds. Then PRESS and hold down
the UP arrow button while turning the rocker power
switch to the ON position.
NOTE:
If power switch does not turn off timers, the
unit must be unplugged (two people may be needed).
The timer will turn ON and the display will now be
indicating
:
The BEEPER will BEEP 4 times.
If STEP 1 was OK, proceed to STEP 2. If not, retry
Step 1 making sure the power was OFF for at least 30
seconds or more.