![Ke Kelit SELTRON PROMATIC CMP25-2 User Manual Download Page 43](http://html1.mh-extra.com/html/ke-kelit/seltron-promatic-cmp25-2/seltron-promatic-cmp25-2_user-manual_3809089043.webp)
46
Technical data
TECHNICAL DATA
General technical data
Power supply
...................................................................
230 V ~ , 50 Hz,
Consumption
....................................................................
Max. 4 VA
Pump output
.....................................................................
230 V ~ / 4 (2) A
Housing
............................................................................
ABS
-
thermoplastic
Dimensions (w x h x d):
...................................................
84 × 105 × 100 mm
Weight
..............................................................................
900 g ÷ 950 g
Color / material
.................................................................
dark grey / PC
Degree of protection
........................................................
IP42 by EN 60529
Safety class
......................................................................
II by EN 60730
-
1
Temperature control class
................................................
III (without room temp. sensor)
VII (with room temp. sensor)
Type of operation
.............................................................
Tip 1B by EN 60730
-
1
Ambient temperature
........................................................
0 to +40 °C
Storing temperature
......................................................... -
20 to +70 °C
Technical specifications:
Day temperature setting range:
........................................
10 °C ÷ 30 °C
Night temperature setting range:
......................................
10 °C ÷ 30 °C
Heat curve setting range:
.................................................
0.2 ÷ 2.2
Frost protection temperature:
...........................................
+ 6 °C (adjustable)
Dead zone range of PI controller:
....................................
± 0.7 K ÷ ± 1.5 K
Temp. sensor type:
..........................................................
Pt1000 or KTY
-
10
Program timer:
.................................................................
multi channel program timer