To avoid the possibility of causing injury to users or damage to properties, please follow all the explanations written below.    

  

This symbol denotes an action that is COMPULSORY.

This symbol denotes an action that is PROHIBITED.

WARNING

A state that  may be caused by the mishandling of products, which, if not avoided, 
may lead to the possibility of death or serious injury of users.

CAUTION

A state that  may be caused by the mishandling of products, which, if not avoided, 
may result in the injury of users or property damage.

Safety precautions

Always follow these instructions

WARNING

Do not install the Ceiling Fan near chemicals and 
alkaline.

Can cause 

fi

 re, explosion, short circuit and electrical 

shock.

Do not damage the wire during installation e.g. 
deform due to heat, twist, bend, etc. 

Can cause 

fi

 re, explosion, short circuit and electrical 

shock.

Do not use power supply other than rated voltage 
mentioned.

Overheating can cause electrical shock and 

fi

 re.

Do not insert any metal items in the battery area 
with the Battery.

Can cause 

fi

 re, explosion, short circuit and electrical 

shock.

Do not hang onto the Ceiling Fan.

Can cause injury if Ceiling Fan drops.

Do not disassemble the Ceiling Fan unless stated 
by this manual.

Must use only supplied parts.
Can cause 

fi

 re, electrical shock, injury and Ceiling Fan 

to drop.

Do not touch the Ceiling Fan while it is operating.

Can cause injury, damage and Ceiling Fan to drop.

Do not sprinkle water to the Ceiling Fan or do not 
wet the Ceiling Fan.

Can cause 

fi

 re, explosion, short circuit and electrical 

shock.

Follow strictly all the instructions given in this 
manual for installation.
Electrical or installation work needs to be performed 
by a quali

fi

 ed individual.

Installation error can cause 

fi

 re, electrical shock, injury 

and Ceiling Fan to drop.

Switch off the power supply and wait until the 
Blades is fully static, before cleaning or doing any 
maintenance jobs.

Can cause injury and electrical shock if Ceiling Fan 
move suddenly.
Kindly refer to your authorized dealer for repairing or 
maintenance issue.

Tighten the Blade Screws 

fi

 rmly using a 

screwdriver.
(250-300 N•cm)

Can cause injury if Blade drops.

Ensure that the Ceiling Hook can sustain more than 
10 times the Ceiling Fan weight.

Can cause injury if Ceiling Fan drops.

Stop using the Ceiling Fan when any abnormality or 
failure occurs and turn “OFF” the Miniature Circuit 
Breaker (MCB).

Risk of smoke, 

fi

 re, electrical shock and drop.

Please contact your authorized dealer for maintenance/
repair.

Dismantle the broken or damaged Ceiling Fan.

Can cause injury if Ceiling Fan drops.

If unusual oscillating movement is observed, immediately 
stop using the Ceiling Fan and contact the manufacturer, 
its service agent or suitably quali

fi

 ed persons.

Can cause injury if Ceiling Fan drops.

Do not install the Ceiling Fan at oily and dusty 
places.

Can cause 

fi

 re, explosion, short circuit and electrical 

shock.

Do not install the Ceiling Fan near 

fl

 ammable areas 

such as a gas cooker.

Can cause 

fi

 re, explosion, short circuit and electrical 

shock.

Summary of Contents for K15YC

Page 1: ...C K15UC K12YC K12UC Net Weight Berat Bersih K12YC 4 9 kg Net Weight Berat Bersih K12UC 5 2 kg Safety precautions 2 3 Maintenance 8 Name of parts 9 10 How to install 11 18 How to use 19 Back Cover Spec...

Page 2: ...op Do not sprinkle water to the Ceiling Fan or do not wet the Ceiling Fan Can cause fire explosion short circuit and electrical shock Follow strictly all the instructions given in this manual for inst...

Page 3: ...all the Blades if any of them breaks or cracks Wobbling can cause Ceiling Fan to drop The mounting of the suspension system shall be performed by the manufacturer its service agent or suitably qualifi...

Page 4: ...ahaja Boleh menyebabkan kebakaran kejutan elektrik kecederaan dan Kipas Siling terjatuh Jangan sentuh Kipas Siling ketika ia sedang beroperasi Boleh menyebabkan kecederaan kerosakan dan Kipas Siling t...

Page 5: ...Bilah Kipas jika salah satu daripadanya patah atau retak Kipas Siling boleh terjatuh akibat bergoyang Pemasangan sistem gantungan hendaklah dilakukan oleh pengilang ejen servis atau individu yang bert...

Page 6: ...6 250 300 N cm 10 OFF MCB...

Page 7: ...7 2 5 1 20 2 1 Safety precautions Pencegahan keselamatan...

Page 8: ...is broken or damaged remove it from the ceiling and replace with new This is to avoid the Ceiling Fan drops 7 The Ceiling Fan suspension system should be examined at least once every two years 8 Do no...

Page 9: ...9 Name of parts Nama bahagian D K12YC K12UC A B C K12YC K12UC E K15YC K15UC A B D C H K15YC K15UC K12YC K12UC G K15YC K12YC F1 F2 K15UC K12UC F1 F2 F F Name of parts Nama bahagian...

Page 10: ...ri produk asal AMARAN Jangan guna bahagian yang telah diubahsuai selain daripada bahagian yang dibekalkan Boleh menyebabkan kecederaan jika Kipas Siling terjatuh Jangan tanggalkan atau keluarkan Paip...

Page 11: ...20 N 3 d J a U b 4 a b e 1500 1800 N cm c a Note J hook a and U hook b installation method is the same Nota Cangkuk J a dan Cangkuk U b kaedah pemasangan masih sama J a U b 1 Remove the supplied Bolt...

Page 12: ...kkan Pastikan Kipas Siling dipasang dalam keadaan selamat pada Cangkuk Siling dan Kipas Siling tidak senget selepas pemasangan Wayar Keselamatan dililit pada Cangkuk Siling dan diskru pada Paip dengan...

Page 13: ...ah c kepada Terminal h seperti panduan pendawaian yang ditunjukkan Panjang pelucutan wayar yang disyorkan adalah 7 8 mm c h 7 8 Connect to the power supply according to the wiring diagram below Sambun...

Page 14: ...ras Ferit Motor PCB Assy Papan Litar Motor Brown Live Coklat Hidup Source Sumber Blue Neutral Biru Neutral Green Yellow Earth Hijau Kuning Bumi Wi Fi Module Modul Wi Fi Wi Fi How to install Cara pemas...

Page 15: ...akukan oleh orang yang berkelayakan Gunakan 227IEC53 RVV atau tiub yang berketebalan lebih dari 1 mm Keperluan lain seperti diameter wayar sila gunakan mengikut peraturan negara negara berkenaan Boleh...

Page 16: ...K12YC and K12UC detach the Lower Canopy B from all hook w For K15YC and K15UC remove the Screw 2 pieces j from Lower Canopy B 2 Align the Upper Holder k2 of the Motor Unit C between the two Fixing Rib...

Page 17: ...ngkuap Atas A ke dalam Slot l2 Pemegang Sengkuap u pada Paip d Untuk K12YC dan K12UC sejajarkan dan masukkan Rusuk Penetap m1 Sengkuap Atas A ke dalam Slot m2 Sengkuap Bawah B 2 Periksa ruang di antar...

Page 18: ...s 30 mm Hole diameter s is 6 mm Attention The Wall Plugs are not needed for wooden wall Pasang Pemegang Alat Kawalan Jauh F2 pada dinding Pasang Pemegang Alat Kawalan Jauh F2 menggunakan Skru o 2 bata...

Page 19: ...nting after installation iii Ensure Bolt and Nut are fully tighten If Ceiling Fan still wobbles after Step 3 3 page 15 please refer to authorized dealer Perhatian Jika Alat Kawalan Jauh anda hilang at...

Page 20: ...Remote Control can cause signal transmission failure Perhatian Penggunaan kuasa apabila operasi kipas dimatikan dan fungsi Wi Fi dimatikan oleh Alat Kawalan Jauh ialah kira kira 0 5 W Adalah digalakk...

Page 21: ...d OFF Long beeping sound 1 Butang OFF ON Tekan untuk menggerakkan atau menghentikan Kipas Siling ON Bunyi bip pendek OFF Bunyi bip panjang 2 Butang SPEED Meningkatkan Kelajuan Kipas kelajuan maksimum...

Page 22: ...dengaran apabila had maksimum atau minimum kecerahan cahaya LED dicapai LED LED Fan Speed can be adjusted by Remote Control This fan is equipped with MEMORY FUNCTION to restore user s last setting whe...

Page 23: ...ti 2 Fungsi Pengumpulan Membuat kawalan berpusat sehingga 8 Kipas Siling secara serentak 3 Fungsi Penjadualan Fungsi termasuk operasi Kipas dan Lampu Menetapkan Kipas Siling supaya menjalankan fungsi...

Page 24: ...2UC Menetapkan 4 tetapan cahaya untuk aktiviti harian pengguna 7 Fungsi Bertentangan Arah boleh beroperasi melalui Alat Kawalan Jauh atau Applikasi Kipas berpusing ke arah yang bertentangan untuk meng...

Reviews: