Check the Ceiling Fan condition annually. If a 

problem occurs, stop using the Ceiling Fan. Then 

refer to authorized dealer.

 

Check point:

Loosened screws, safety wire condition, motor shaft 

damage, etc.

2

Ensure the Safety Switch is in good condition.

If a problem occurs, stop using the Ceiling Fan. 

Then refer to authorized dealer.

3

Keep the Ceiling Fan clean. Wipe away dirt with 

a clean soft cloth, ordinary soap and water. Wipe 

it again to dry it. Do not use solvents (gasoline, 

petroleum, thinner, benzine, alcohol, cleaning 

powder, alkaline detergent) or any other chemicals.

• Do not bend the Blade while cleaning.

4

Do not paint the Blades. If damaged, order a new set 

of Blades (3 pieces) from an authorized dealer.

5

When referring to an authorized dealer, show these 

instructions to them and maintain correctly.

6

If the product is broken or damaged, remove it from 

the ceiling and replace with new. This is to avoid the 

Ceiling Fan drops.

7

The Ceiling Fan suspension system should be 

examined at least once every two years.

8

Do not modify or repair the LED light. If a problem 

occurs, refer to authorized dealer (for E48GP).

Safety Switch / 

ԊӒ໠ᜰ

Switch Lever / 

໠ᜰ؋

Wrong Position /

ᒿᇲ՝ည

Correct Position /

ғጂ՝ည

Maintenance

ᆰও

1

፜ؐԑۡਢᔮࢥӤਉޟޑݷȄԃݎю౪୰ᚠȂ፜ୄХٺ
ҢԤᜰӤਉȄġณࡣ፴ၚ݈୛ܖ௲᠌င᎛୦Ȅ

 

ᔮࢥᘈ

:

ᖳ๛ᚬಳȂ߳ᓎጣޑݷȂีଢ଼ᐠᙽଢ଼໅ཬᚽ้้Ȅ

2

ጂ߳ԊӒ໠ᜰġ೎ܻيԁޑᄘȄ
ԃݎю౪୰ᚠȂ፜ୄХٺҢԤᜰӤਉȄ
ณࡣ፴ၚ݈୛ܖ௲᠌င᎛୦Ȅ

3

߳ࡻӤਉ఼ዓȄҢୁ౑ޟ೺Ҁȃල೽޳غڷЫܡўԴ
ၬȄӔܡΙԩ஠ϞܡୁȄϸϼٺҢྙᏘȞءݶȂݶȂใ
ភᏘȂॄȂନᆠȂўԴ઱ڷᢃܒࢿᅥᏘȟܖӈդڏтϽ
ᏰސࠢȄ

ġ

˙

఼ࢿਉᖎਢ፜ϸϼ׷᠉ਉᖎȄ

4

ϸϼ࣏ਉᖎ༯ᅘȄषਉᖎཬᚽΟȂ፜௲୦ॏᗊཱིޟਉᖎġ

(3

ġݛ

)

Ȅ

5

࿋ௌ፴ၚ௲᠌င᎛୦ਢȂ፜өтঈюҰԪࡾҰਪо߯т
ঈғጂӴ໌՗ᆰওȄ

6

ष౰ࠢϐ׷ᘞܖཬᚽȂ፜௃Ј߆ݖΰܶଶӤਉȂณࡣ඲
ΰཱིޟӤਉȄ೻࢐࣏Ο٩ХӤਉ௬ဣȄ

7

࡚ដؐڍԑՍЍᔮࢥӤਉ᝚௮فಛΙԩȄ

8

፜ϼ׽၆ܖও౩၎ġ

LED

ġᐷȄԃݎีҡޑݷȂ፜ᖒ๜௲᠌

င᎛୦

 (

ᎌҢܻ

 E48GP).

Summary of Contents for E48HP

Page 1: ...Instructions Ceiling Fan Thank you for purchasing this KDK product Before operating this product please read the instructions carefully and save this manual for future use Safety precautions 2 3 Main...

Page 2: ...the Ceiling Fan or do not wet the Ceiling Fan Can cause fire explosion short circuit and electrical shock Do not install the Ceiling Fan at a wet high temperature and high humidity area such as shower...

Page 3: ...ation make sure the Ceiling Fan does not wobble extremely Can cause injury if Ceiling Fan drops Replace all the Blades if any of them breaks or cracks Wobbling can cause Ceiling Fan to drop The mounti...

Page 4: ...4 250 300 N cm 10 MCB...

Page 5: ...5 2 3 1 15 2 1 Safety precautions...

Page 6: ...hol cleaning powder alkaline detergent or any other chemicals Do not bend the Blade while cleaning 4 Do not paint the Blades If damaged order a new set of Blades 3 pieces from an authorized dealer 5 W...

Page 7: ...Ceiling Fan drops Do not disassemble or remove the pipe from Motor Unit Can cause fire electrical shock injury and Ceiling Fan to drop Parts piece s A Upper Canopy 2 B Lower Canopy 2 C Motor Unit 1 D...

Page 8: ...Plain Washer from holes b Carl Bolt Plug J Make sure Carl Bolts remain strong on the ceiling 6 Fix the Hanger Base K to the concrete ceiling and replace the removed Plain Washer Spring Washer and Hex...

Page 9: ...Carl Bolt Plug I Loop the Safety Wire g to the Hanger Base K and install Safety Wire as shown Replace the removed Plain Washer Spring Washer and Hexa Nut and tighten them 5 I a g K 5 g Plain Washer Sp...

Page 10: ...ower PCB Assy PCB Terminal Safety Switch LED Circuit PCB Assy LED PCB Sub PCB Assy PCB Ferrite Core Motor PCB Assy PCB Brown Live Source Blue Neutral Green Yellow Earth Wi Fi Module Wi Fi E48GP Wiring...

Page 11: ...eck point after installation The wiring is connected properly to the power supply Attention 1 It is recommended to user to install OFF ON switch on the wall for the Ceiling Fan replacing existing regu...

Page 12: ...Blade Screws H provided Use 2 screws for one Blade Assembly For reference tightening torque is 250 300 N cm Ensure the Blade Assembly D screw hole is center with the Motor Unit C screw hole Hold the B...

Page 13: ...pieces i from Upper Canopy A Align and insert the Fixing Rib m1 of Upper Canopy A into the Slot m2 of Lower Canopy B 2 Check the gap between the Upper Canopy A and ceiling is approximately 5 mm or mor...

Page 14: ...user s last setting when switched on by wall switch or it can be switched on through App If the Ceiling Fan is found to wobble during operation i Fix the Blades at different combination of position Re...

Page 15: ...setting may be change at the same time 1 The figure above shows the best coverage area W around 8 m The ideal ceiling height H is 4 m The Remote Control must be pointed to the direction of the Ceilin...

Page 16: ...an speed is 10 3 SPEED Button Decrease Fan Speed minimum fan speed is 1 4 REVERSE Button Change the direction of fan rotation clockwise anticlockwise 5 Wi Fi Button Press to activate or off the Ceilin...

Page 17: ...n reach the maximum or minimum limit of LED brightness Fan Speed can be adjusted by Remote Control This fan is equipped with MEMORY FUNCTION to restore user s last setting whenever fan is switched on...

Page 18: ...rature of the LED light can be changed and adjusted by Remote Control White Color Press and hold WHITE Color button to adjust the White color temperature gradually Warm Color Press and hold WARM Color...

Page 19: ...the Ceiling Fan by setting timer count down 5 1 f YURAGI function natural breeze Add smooth accent of air capacity that produces more natural and comfortable wind 1 f YURAGI function will be activated...

Page 20: ...requency Hz Hz 50 Wattage W Speed 1 Speed 10 Fan only W 1 10 3 31 3 31 Fan and Light 22 50 Air Delivery m3 min m3 min 200 Air Velocity m min m min 185 Rotation RPM Speed 1 Speed 10 RPM 1 10 Forward 55...

Reviews: