background image

 

Maintenance 

 

17 

 

   

 

IMPORTANT 
After use or before storing: Always wash out 
the pump using fresh water.

 

 
Do not use alcohol for cleaning acrylic parts. 
 
Give plankton nets proper care and 
maintenance. Do not let particulate matter 
dry on the net because it can significantly 
reduce size of mesh apertures and increase 
frequency of clogging. 
 
Wash net thoroughly with fresh water after 
use. Periodically clean with a warm soap 
solution. It is also advisable letting the net to 
air-dry after washing. 
 
KC Denmark A/S is not, and cannot be held, 
responsible for any damage(s) made to 
equipment or to operators who ignore safety 
precautions or because of misuse or wrong 
operation. 

 

 

18 

There are two zinc anodes on top of the pump, and 
we strongly recommend these when operating the 
pump in salt water.  
 
The zinc anode (28.102) protects against corrosion 
of the pump. Replace once the material is eroded. 

 

 

 

 

 

Summary of Contents for 23.580

Page 1: ...Pump for Micro Plastic Particles Model 23 580 Manual KC Denmark Research Equipment Limnology Oceanography Hydrobiology...

Page 2: ...a constant relief of the cable in its entire length to avoid any cable damage because of the cable s weight In order to cool the motor it is important deploying the pump beneath the water surface bef...

Page 3: ...ssemble the connector take care so you don t lose the eye and the screw 5 Connect the cable with the CEE plug on the right side of the control box The cable is for the main supply of 230 VAC 1 ph Conn...

Page 4: ...wn 9 The pump s flow goes from the middle of the cylindrical pump through the filter unit and the flow meter then having output at the pumps lower end Insert the filter unit using the coarse filter on...

Page 5: ...tton to stop the pump 15 Programmable pump volume Tapping the display shows an intuitive display Add the requested volume measured in litres Press enter and the display returns to live view Press the...

Page 6: ...t thoroughly with fresh water after use Periodically clean with a warm soap solution It is also advisable letting the net to air dry after washing KC Denmark A S is not and cannot be held responsible...

Page 7: ...23 580 Manual Pump for Micro Plastic 7...

Page 8: ...23 580 Manual Pump for Micro Plastic 8...

Page 9: ...23 580 Manual Pump for Micro Plastic 9...

Page 10: ...23 580 Manual Pump for Micro Plastic 10...

Page 11: ...etic inductive accuracy typical 0 035 Pump dimensions Footprint max 60 x 60 cm Height total 137 cm Weight pump incl steering fin 49 2 kg Maximum depth 40 m Control box dimensions Footprint 46 x 46 cm...